Page 31

MS-3 Laser E.book Page 7 Monday, August 30, 2004 11:09 AM

Chapter 2 Using ESP Terminal tab When Show Non-Printable Characters is checked, characters such as CRLF will be displayed in the terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting. Change Keyboard Macros In this dialog you can first select the function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F5 the keystroke to enable send a trigger character, select F5, then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F5 keystroke is pressed, the trigger character will start the read cycle. Change Font Sets the font characteristics for the commands that you type in the terminal window. Change Echo Font Sets the font characteristics for text that is echoed back to the screen from the reader. Toolbar Style By user selection, displays toolbar buttons as icons, text only, or both (default). Note: See also Chapter 14, “Terminal Mode.”

MS-3 Laser Reader User’s Manual

2-7

Page 32

MS-3 Laser E.book Page 8 Monday, August 30, 2004 11:09 AM

Pulldown Menus Bar Code Options tab Sets up the sizing, font, and caption parameters for the bar codes that you can create and print from the Bar Code Options Dialog under View. Sizing Information Sets the bar height (in inches) and bar widths (in thousands of an inch) of the symbols. A bar width of 13 is 0.013 inches. Caption Sets the characteristics of caption font and its placement in relation to the bar code symbol. Advanced tab As indicated.

Document Memo Whatever you type into the Document Memo will appear in a text box whenever your cursor hovers over the Document Memo option.

Model Memo Memos created in Model Memo are specific to the model enabled when the message was created.

2-8

MS-3 Laser Reader User’s Manual

Page 33

MS-3 Laser E.book Page 9 Monday, August 30, 2004 11:09 AM

Chapter 2 Using ESP

Connect Menu Autoconnect Generally Autoconnect will be the quickest way that ESP can get connected to a reader. Autoconnect will try connecting at the most common communications settings and step through the various settings until they match up with the host’s settings.

Connect When you select Connect, you will need to manually select the communications settings from a popup dialog.

Configure Multidrop To connect to the reader by Multidrop, you will need a multidrop concentrator such as the MS-5000 and the required power supplies and cabling to communicate with your scanner(s). 1. From the Communications drop down menu in ESP, select Configure Multidrop to bring up the Multidrop Settings dialog. 2. If necessary, change the default address to match the address of your multidropped scanner and click OK. If the host serial port is not connected in ESP, you will see the following popup message: ESP is not currently connected to the multidrop concentrator. Do you wish to establish a connection now? 3. Click Yes. You will see a Serial Communication Parameters dialog as shown on the next page.

MS-3 Laser Reader User’s Manual

2-9

Page 34

MS-3 Laser E.book Page 10 Monday, August 30, 2004 11:09 AM

Connect Menu 4. Select the concentrator’s host port communications settings. When you click Connect, you will be connecting to your concentrator, which can then relay commands to the scanner whose address was set in the Multidrop Settings dialog. 5. Click Connect. 6. You should see the CONNECTED message in green at the bottom of the window along with the scanner’s Multidrop address.

7. Do Retrieve Scanner Settings to upload scanner’s configuration (Step 4). If upload fails, return to the Serial Communication Parameters dialog and make the corrections. 8. Follow the same procedure for connecting other scanners to your multidrop network. Note: For more information, see your scanner user’s manual or Microscan’s MS-5000 Multidrop Concentrator User’s Manual, 83-005000.

2-10

MS-3 Laser Reader User’s Manual

Page 35

MS-3 Laser E.book Page 11 Monday, August 30, 2004 11:09 AM

Chapter 2 Using ESP

View View indicates the current view (with a dot before the item) and allows you to quickly move to other views which are also accessed by clicking the icons on the toolbars. It also allows you to access the Barcode Dialog.

Barcode Dialog In the Barcode Dialog you can create bar code symbols by directly typing in the text bar code text you want to appear in Code 128 bar code symbols. This is a very useful tool for creating configuration symbols which allows you to configure your reader by reading the bar code symbols you print out. To configure the size, text and caption parameters, see “Bar Code Options tab” on page 2-8.

MS-3 Laser Reader User’s Manual

2-11

Page 36

MS-3 Laser E.book Page 12 Monday, August 30, 2004 11:09 AM

Navigating in ESP

Navigating in ESP To change reader settings, or to access the utilities or terminal window, click on the App Mode button.

To return to the Easy Mode, click on the EZ Mode button.

To make changes to a configuration setting in the menu trees: 1. Left click on the + to expand tree 2. Double click on parameter and click once in selection box to view options. 3. Place your curser in the selection box, scroll down to the setting you want to change and click once on the setting. 4. Left click again on the open screen to complete the selection.

2-12

5. Right click on the open screen and select Save to Reader to implement the command in the reader.

MS-3 Laser Reader User’s Manual

Page 37

MS-3 Laser E.book Page 13 Monday, August 30, 2004 11:09 AM

Chapter 2 Using ESP

Send/Receive Options To access Receive, Save and Default options, click the Send/Recv button: You can also access this selector by right-clicking in any of the configuration views.

Receiving From the Send/Recv selector, select Receive Reader Settings. Caution: Do no select this option if you do not want to upload the reader’s settings. For example, if your ESP file has a number of custom settings that you want to maintain and download into the reader, these settings would be lost by choosing Yes. This is useful if you want to receive (upload) the reader’s settings and save them as a computer file for later retrieval. For example, if your reader has settings that you do not want to change, choosing Yes would allow you to load those settings to ESP and save as an ESP file for later retrieval. Receiving the reader’s settings will also assure that you will not be subsequently saving any unwanted changes that you or someone else previously made in ESP. See “Send/Receive Options” on page 2-13 for more detail.

Saving 1. Send, No Save. (same as <A>) This saves ESP settings to current memory. 2. Send and Save. (same as <Z>) This activates all changes in current memory and saves to the reader for power-on. 3. Send and Save as Customer Defaults. (same as <Zc>) (This option will be visible only if you had checked Enable ‘Send and Save as Customer Defaults’ in ESP Preferences in the Options menu.) Use this to save your own set of default settings that you can quickly retrieve with a <Zrc> command. For more on defaulting and saving settings, see “Defaulting/Saving/Resetting” on page A-20.

MS-3 Laser Reader User’s Manual

2-13

Page 38

MS-3 Laser E.book Page 14 Monday, August 30, 2004 11:09 AM

Send/Receive Options

Defaulting When you select Default Current... or Default all ESP... you are only defaulting the ESP settings.

Advanced Options Send Current View This is the same as Save to Reader, Send No Save except that only the commands in the current menu tree are sent.

Send Current Command This is the same as Send Current View above, but only saves the command that is currently selected.

Add Exceptions After you perform a Receive from Reader command1 and you click on the Add Exception option you may see a list of serial commands that looks like the example to the right. These are serial commands that may be in your reader’s firmware, but not included or different from your current ESP software. You can edit these commands by double-clicking on them and changing as needed. When exceptions are present, you can also access them from an Exceptions button that will appear on the Applications button bar. It is important to note that these commands will be saved to your reader whenever you do a Save to Reader command or send an <A> or a <Z> command. Also, if there is a corresponding ESP menu item, the ESP Value column for that item will be blank following a Receive from Reader command.

1. From the Send/Recv button or right-clicking from within the tree menus.

2-14

MS-3 Laser Reader User’s Manual

Page 39

MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM

Communications

Chapter

3 Chapter Contents Communications by ESP.............................................................................3-2 Communications By Serial Command.........................................................3-2 Password Protection ...................................................................................3-3 RS-232/422 Host Port .................................................................................3-4 RS-232 Auxiliary Port ................................................................................3-11 Preamble ...................................................................................................3-20 Postamble .................................................................................................3-21 LRC Status ................................................................................................3-22 Intercharacter Delay ..................................................................................3-22

The ESP™ (Easy Setup Program), configuration changes can be made in the ESP menus, then sent and saved to your reader. The user can also send serial commands to the reader via the ESP’s Terminal window. This section includes connecting parameters and options for communicating by the auxiliary port and various interfaces. Note: When assigning characters in user-defined fields, the characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands. Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?>. To see all “K” commands, send <K?>. Note: Default settings for establishing communications are: Baud =

9600

Parity =

Even

Stop Bits =

One

Data Bits =

Seven

Flow Control = None Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?> To see all “K” commands, send <K?>.

MS-3 Laser Scanner User’s Manual

3-1

Page 40

MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM

Communications by ESP

Communications by ESP

Click this button to bring up the Communications menu.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?> To see all “K” commands, send <K?>.

Communications By Serial Command Command Title Password Status Password Entry, Change Host Port Parameters Host Protocol Host RS422 Status Aux Port Parameters Preamble Postamble LRC Status Intercharacter Delay

3-2

Format <K732,status> <K733password,new password> <K100,baud,parity,stop bits,data bits> <K140,protocol> <K102,status> <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain status,daisy chain ID> <K141,preambole status,preamble> <K142,postamble status,postamble> <K145,status> <K144,intercharacter delay>