Page 181

MS-3 Laser E.book Page 9 Monday, August 30, 2004 11:09 AM

Chapter 11 Utilities

Enter Master Symbol Data Definition:

Allows you to enter master symbol data for a specific master symbol index number (1 to 10), provided the index number is not larger than the number of symbols enabled by the Master Symbol Database Size (see page 11-8). For example, if Master Symbol Database Size is set to 2, you will not be able to enter data for symbols 3 through 10.

ESP:

1. Double-click on each index number you want to setup and copy or type in your data in the popup data entry box. 2. Click on the Send Database to Reader button. Note: You can also click Receive Reader’s Database to enter the scanner’s current database settings or click Read Symbol into Selected Index to enter the data from a symbol that is in the scanner’s read range.

Serial Cmd:

<K231,master symbol number,master symbol data>

Default:

1, blank

Options:

1 to 10, any combination of ASCII text up to the maximum indicated in “Maximum Characters for Master Symbol Database” on page 11-10. For example, to enter data for master symbol 9, after making certain that master symbol database size is enabled for 9 or more symbols (see “Master Symbol Database Size” on page 11-8), send <K231,9,data>.

Caution: Since the total number of characters available for the master symbol database is 128, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol #1 unless it also exceeds the size limitation). Table 11-3, “Maximum Characters for Master Symbol Database,” on page 1110 specifies the maximum number of characters available to each symbol according to the number of master symbols defined, from 1 through 10. See “Master Symbol Database Size” on page 11-8.

MS-3 Laser Scanner User’s Manual

11-9

Page 182

MS-3 Laser E.book Page 10 Monday, August 30, 2004 11:09 AM

Master Database Table 11-3 Maximum Characters for Master Symbol Database Master Symbol Number #1 #2 #3 #4 #5 #6

Maximum Characters 127 62 39 28 20 15

Note: See Chapter 7, “Master Symbol Database” for information on master symbol database and related commands.

Store Next Symbol as Master Symbol Definition:

After you’ve set the size in the database, you can order the scanner to scan-in the next symbol as master symbol 1.

Serial Cmd:

<Gmaster symbol number> To store the next symbol scanned as master symbol #1 send: <G> or <G1>. For all symbols numbers except 1, the number must be included.

Options:

1 to 10

11-10

MS-3 Laser Scanner User’s Manual

Page 183

MS-3 Laser E.book Page 11 Monday, August 30, 2004 11:09 AM

Chapter 11 Utilities

Digital Bar Code When you click the Digital Bar Code tab and the Start button, a digitized representation of the symbol in front of the scanner will appear. This routine is useful for conveying a sense of the symbol’s readability and graphically indicating bad or unreadable portions of symbols, extraneous “noise,” etc. A green waveform indicates a decoded symbol; a red waveform indicates an undecoded symbol or other object. The read triangles represent the width of the scan beam relative to the symbol. The upward pointing arrows indicated the symbol’s margin.

Zoom In, Zoom Out You can zoom in by sliding the Zoom lever to the right. You may have to scroll right or left to locate your symbol, but the results will be striking.

MS-3 Laser Scanner User’s Manual

11-11

Page 184

MS-3 Laser E.book Page 12 Monday, August 30, 2004 11:09 AM

Firmware

Firmware Firmware Update is used to download application code to the reader.

Application code versions are specific to your reader. Consult with your sales representative before downloading application code. If needed, an application code will be sent to you in the form of a *.mot file. To download application code: 1. First make sure the host is connected to your reader. 2. Apply power to the reader. 3. In the Firmware Update pulldown window, select App Code. This will open a file dialog box. 4. Navigate to the appropriate file (a *.mot file) and open the file. 5. Allow a minute or so for the firmware to download. As application code begins to download to the reader, the reader will go silent, the reader’s RDY and GD/RD LEDs will flash intermittently, and a progress indicator at the bottom of the ESP window will let you know when the download is complete. Caution: Do not interrupt power or disconnect the host cable while download is in progress.

Firmware/Checksum Verification From Firmware Verification you can request the part number and checksum from by selecting App Code or Boot Code and clicking the accompanying Request... button.

11-12

MS-3 Laser Scanner User’s Manual

Page 185

MS-3 Laser E.book Page 13 Monday, August 30, 2004 11:09 AM

Chapter 11 Utilities

Device Control Outputs You can access Device Control from the Utilities menu.

Output # 1 Pulse Definition:

Activates the link between Output 1 (+) and Output 1 (–) of the host connector for the duration set by “Pulse Width” on page 6-19. (regardless of Master Symbol or Output 1 status).

ESP:

Click Output # 1 Pulse to activate.

Serial Cmd:

<L1>

Output # 2 Pulse Definition:

Activates the link between Output 2 (+) and Output 2 (–) of the host connector for the duration set by “Pulse Width” on page 6-19. (regardless of Master Symbol or Output 2 status).

ESP:

Click Output # 2 Pulse to activate.

Serial Cmd:

<L2>

Output # 3 Pulse Definition:

Activates the link between Output 3 (+) and Output 3 (–) of the host connector for the duration set by “Pulse Width” on page 6-19. (regardless of Master Symbol or Output 3 status).

ESP:

Click Output # 3 Pulse to activate.

Serial Cmd:

<L3>

MS-3 Laser Scanner User’s Manual

11-13

Page 186

MS-3 Laser E.book Page 14 Monday, August 30, 2004 11:09 AM

Device Control

Extras You can access Device Control from the Utilities menu

Disable Reader Usage:

This feature is useful during extended periods of time when no symbols are being scanned or the reader is being configured.

Definition:

Sending <I> will turn the laser off and end the current read cycle.

ESP:

Click Disable Reader button.

Serial Cmd: <I> Disabling laser scanning will not affect any downloaded commands to the reader.

Enable Reader Definition:

Causes the laser scanner to be on continuously.

ESP:

Click Enable Reader button.

Serial Cmd: <H> Note: Enable/Disable Reader does not relate to Laser On/Off command.

Send Motor Off Usage:

This feature is useful during extended periods of time when no symbols are being scanned or the reader is being configured.

Definition:

Turns the spinning mirror off (if not already running).

ESP:

Click Send Motor Off button.

Serial Cmd:

<KF>

Send Motor On Usage:

This feature is useful during extended periods of time when no symbols are being scanned or the reader is being configured.

Definition:

Turns the spinning mirror on (if not already running).

ESP:

Click Send Motor On button.

Serial Cmd:

<KE>

11-14

MS-3 Laser Scanner User’s Manual

Page 187

MS-3 Laser E.book Page 15 Monday, August 30, 2004 11:09 AM

Chapter 11 Utilities

Symbol Type Sending <P> enables the scanner to decode all available symbol types except Pharmacode and PDF417 without changing scanner configuration. Sending <Q> enables the scanner to decode Code 39 symbols without changing scanner configuration. Sending <R> enables the scanner to decode Codabar symbols without changing scanner configuration. Sending <S> enables the scanner to decode I 2 of 5 symbols without changing scanner configuration.

MS-3 Laser Scanner User’s Manual

11-15

Page 188

MS-3 Laser E.book Page 16 Monday, August 30, 2004 11:09 AM

Defaulting/Saving/Resetting

Defaulting/Saving/Resetting Table 11-4 Software Reset/Save/Recall Commands <A> <Ard> <Arp> <Arc> <Z> <Zc> <Zrd> <Zrc>

Reset (does not save for power-on) Reset and recall Microscan defaults Reset and recall power-on parameters Reset and recall customer default parameters Save current settings for power-on Save current settings as customer default parameters Recall Microscan Wenglor default parameters and save for power-on Recall customer parameters and save for power-on

See Appendix G, “Defaulting/Saving/Resetting” on page A-20 for complete explanation on resets, saves and defaulting.

11-16

MS-3 Laser Scanner User’s Manual

Page 189

MS-3 Laser E.book Page 17 Monday, August 30, 2004 11:09 AM

Chapter 11 Utilities

Microscan Grading Microscan Wenglor grading informs the user how the scanner perceives a symbol it is scanning. Except for special circumstances, the slower the scan speed and the closer the symbol is to the focal point, the more accurate the results. The grading feature is available for the following symbologies: Code 39, Codabar, Code 128, I-2/5, and Code 93.

Command Format <GRADE,xx.xx> where xx.xx is the symbol length in inches with up to two digits in front of the decimal point and two digits behind the decimal point. Example: Send <GRADE,01.50> for a symbol 1.5 inches in length.

Operation Once the command has been sent, the scanner will enter a user test mode for up to two full seconds. During this time the scanner will attempt to complete ten decodes of the samesymbol. If this occurs, the scanner will output the grading information for this symbol.

Microscan Wenglor Grading Output Example:

The following information is output: • Symbol Type - The type of symbol decoded. • Symbol Direction - The direction of the symbol presented to the scanner. • Symbol Length - The length of the symbol data encoded. • Symbol Data - The data encoded in the symbol. • Check Character - Displays the check digit type that the scanned symbol complies with. If the symbol does not comply, then the scanner outputs “Failed.”

MS-3 Laser Scanner User’s Manual

11-17

Page 190

MS-3 Laser E.book Page 18 Monday, August 30, 2004 11:09 AM

Microscan Grading • Decodability - Calculates the decodability of the symbol using the video acquired by the reader. The calculations are consistent with ANSI X3.182-1990 however the it is important to note the measurements used to acquire the symbol information are proprietary and are not ANSI compliant. • W/N Ratio - Calculates the wide to narrow ratio of the symbol using the video acquired by the reader. The calculations are consistent with ANSI X3.182-1990 however the it is important to note the measurements used to acquire the barcode information are proprietary and are not ANSI compliant. • Average Narrow Bar - Calculates the wide to narrow ratio of the symbol using the video acquired by the reader. The calculations are consistent with ANSI X3.1821990 however the it is important to note the measurements used to acquire the barcode information are proprietary and are not ANSI compliant. • Average Bar Error - Calculates the average bar error in relation to the spaces and the average narrow element. This is a good representation of the amount of over or under printing. • Intercharacter Gap - Measures the largest intercharacter gap within the symbol. If the symbol does not have intercharacter gaps then N/A is output. • Margin - Measures the size of the smallest margin around the symbol.

11-18

MS-3 Laser Scanner User’s Manual