The text of a manual · part 18 of 25
MS-3 Laser Scanner User's Manual, pages 171 to 180
Pages 171 to 180 of 242
The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-3
Page 171
MS-3 Laser E.book Page 5 Monday, August 30, 2004 11:09 AM
Chapter 10 Terminal Mode
Terminal Window Functions Right-click on the terminal window to display the following: • Copy selected text to clipboard. • Paste from terminal or computer text. • Clear all text in terminal window. • Select All text in the terminal window. • Save... brings up a save as dialog box. • Change Font... of data text, brings up a text dialog. • Change Echo Font... to change typed in text or commands. • Change Background Color of terminal window. • Default Settings changes all the above back to default settings.
Terminal Pulldown Menu The pulldown Terminal menu has Capture and Save Current Text as well as the functions defined above. • Capture lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the terminal window to a text file of your choice.
MS-3 Laser Scanner User’s Manual
10-5
Page 172
MS-3 Laser E.book Page 6 Monday, August 30, 2004 11:09 AM
Terminal Window Functions
10-6
MS-3 Laser Scanner User’s Manual
Page 173
MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM
Chapter
Utilities
11 Chapter Contents Utilities by ESP Menu ................................................................................11-2 Summary of Utilities Commands ...............................................................11-3 Read Rate .................................................................................................11-5 Counters ....................................................................................................11-6 Master Database .......................................................................................11-8 Digital Bar Code ......................................................................................11-11 Firmware .................................................................................................11-12 Device Control .........................................................................................11-13 Symbol Type ...........................................................................................11-15 Defaulting/Saving/Resetting ....................................................................11-16 Microscan Grading ..................................................................................11-17 Reader Status Requests .........................................................................11-19
Utility commands are generally commands that are performed during reader operations to check read rates, determine read rates or perform miscellaneous operations on reader hardware. Serial utility commands are not prefaced with a “K” and a numeric code, nor do they require an initialization command (<A> and <Z>). They can be entered from within any terminal program or from within ESP in the Terminal window. Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?>. To see all “K” commands, send <K?>. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
MS-3 Laser Scanner User’s Manual
11-1
Page 174
MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM
Utilities by ESP Menu
Utilities by ESP Menu
Click this button to bring up the Utilities menu Utilities opens in the Read Rate utility. Click on the tabs to access other utilities.
Note: Utility commands are not accessible by embedded menus.
11-2
MS-3 Laser Scanner User’s Manual
Page 175
MS-3 Laser E.book Page 3 Monday, August 30, 2004 11:09 AM
Chapter 11 Utilities
Summary of Utilities Commands Table 11-2 Utilities Commands Command Type Read Rate
Counter Request and Clear
Matchcode
Part Number/ Checksum
Device Control
Command <Cp> <C> <J> <N> <O> <T> <U> <V> <W> <X> <Y> <E> <F> <K224,number of master symbols> <)data)> <K231,master symbol number,data> <G> <Gmaster symbol number> <)>
Name Enter Single Symbol Percent Rate Test Enter Single Symbol Decode Rate Test Exit Decode Rate and Percent Rate Test Noread Counter Noread Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Enable Matchcode (see also <K223,...> on page 7-4.) Disable Matchcode (see also <K223,...> on page 7-4.) Set master symbol database size. Also <KMnumber of master symbols> Enter symbol data as master symbol #1. Enter symbol data to specified master symbol. Also <Mmaster symbol number,data> Store next symbol scanned as master symbol #1. Store next symbol scanned as specified master symbol.
Request master symbol #1. Request all master symbol information. <K231, ?> Also <M?> <K231, master symbol Request specified master symbol information. number?> Also <M#?> <K231, master symbol Delete specified master symbol. number,> Also <Mmaster symbol number,> <))> Delete Master Symbol # 1 <K225,status> Enable/disable New master pin <!> Display Checksums of EPROM Flash memory <!b> Display Checksum for Boot Code <!a> Display Checksum for Application Code <#> Display Part Numbers <#b> Display Boot Code Part Number <#a> Display Application Code Part Number <H> Enable Laser Scanning <I> Disable Laser Scanning <K500> or <KE> Motor On <K501> or <KF> Motor Off <L1> Programmable Output 1 <L2> Programmable Output 2 <L3> Programmable Output 3
MS-3 Laser Scanner User’s Manual
11-3
Page 176
MS-3 Laser E.book Page 4 Monday, August 30, 2004 11:09 AM
Summary of Utilities Commands Code Types Trigger
Default/Reset/ Save
Status Requests
<P> <Q> <R> <S> <char> <A> <Ard> <Arp> <Arc> <Z> <Zc> <?> <?1> <K?>
Autodiscriminate All Codes except Pharmacode and PDF417 Enable Code 39 Only Enable Codabar Only Enable I 2/5 Only Serial Trigger Character Reset (does not save for power-on) Reset and recall factory defaults Reset and recall power-on parameters Recall and recall customer default parameters Save current settings for power-on Save current settings as customer default parameters Scanner Status Extended scanner status Configuration status
Note: Utility commands are not accessible by embedded menus.
11-4
MS-3 Laser Scanner User’s Manual
Page 177
MS-3 Laser E.book Page 5 Monday, August 30, 2004 11:09 AM
Chapter 11 Utilities
Read Rate When in a read rate mode, the scanner will output a number preceding the symbol data. This number will represent either the number of decoded scans per second or the percentage of successful decoder per total number of scans. Make a note of the decode rate. It will be a useful reference when calculating the number of decodes (see “Formulas for Number of Decodes” on page A-46).
Read Rate by ESP You can access Read Rate from the Utilities menu. To start or end a read rate test, right-click Read Rate and select Start or Stop. To change from percent read rate to decodes per second, first end the read rate by selecting Stop, then right-click and select Decodes/Sec.
Read Rate by Serial Command Enter Single Symbol Decodes/Second Test Sending <C> instructs the scanner to transmit the decodes per second and symbol data (if any). The decode rate can vary dramatically due to the angle and location of the symbol in relation to the scan line. This test is very useful in aligning and positioning the scanning device during installation.
Enter Single Symbol Percent Test Sending <Cp> instructs the scanner to transmit the percentage of decodes and any scanned symbol data.
End Read Rate Test Sending <J> ends both the Percent test and the Decodes/Second test for both single and multi-symbol.
MS-3 Laser Scanner User’s Manual
11-5
Page 178
MS-3 Laser E.book Page 6 Monday, August 30, 2004 11:09 AM
Counters
Counters Counter commands can be a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, the counter will automatically roll-over and start counting again at 00000. To obtain the cumulative total of counts after the roll-over has occurred, add 65,536 per each roll-over (the scanner does not keep track of the number of roll-overs) to the current count. Note: All counter values will be lost if power is recycled to the scanner or the scanner receives a reset or save command.
Counter by ESP You can access Counters from the Utilities menu. Right-click the appropriate counter option and select Request to display count or Clear to set counter to zero. Or, right-click on Counters and select Request All.
11-6
MS-3 Laser Scanner User’s Manual
Page 179
MS-3 Laser E.book Page 7 Monday, August 30, 2004 11:09 AM
Chapter 11 Utilities
Counters by Serial Command Noread Counter Sending <N> displays the total number of noreads that have occurred since the last reset.
Noread Counter Reset Sending <O> sets Noread Counter to 00000.
Trigger Counter Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset Sending <U> sets the trigger counter to 00000.
Good Read/Match Counter Sending <V> displays the total number of good reads matching the master symbol if Matchcode is enabled. This counter is always enabled, but will only work as a match count when Matchcode is enabled. If Matchcode is not enabled, this counter records the number of good reads. This count can be requested at any time.
Good Read/Match Counter Reset Sending <W> sets the match counter to 00000.
Mismatch Counter With Matchcode enabled, sending <X> displays the number of decoded symbols since the last reset that do not match the master symbol.
Mismatch Counter Reset Sending <Y> sets the mismatch counter to zero.
MS-3 Laser Scanner User’s Manual
11-7
Page 180
MS-3 Laser E.book Page 8 Monday, August 30, 2004 11:09 AM
Master Database
Master Database Important: Master Symbol Database is used only for comparing entire bar codes, when Sequential and Wild Card are NOT enabled, and Start Position is equal to 0. Usage:
Useful where more than one master symbol is required, as in a Multisymbol setup, for matching and other matchcode operations.
Definition:
Allows you to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands.
Master Symbol Database Size Definition:
Master Symbol Database Size allows you to select 1 to 10 master symbols for the master symbol database.
Serial Cmd:
<K224,number of master symbols>
Default:
1
Options:
1 to 10
To access in ESP 1. Click the Utilities button and click the Master Database tab. 2. Click the Matchcode Type checkbox to enable Matchcode. 3. Set the number of master symbols you want to include. Scroll up or down to set the master symbol database size.
11-8
MS-3 Laser Scanner User’s Manual