The text of a manual · part 20 of 25
MS-3 Laser Scanner User's Manual, pages 191 to 200
Pages 191 to 200 of 242
The original document is the PDF (7.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-3
Page 191
MS-3 Laser E.book Page 19 Monday, August 30, 2004 11:09 AM
Chapter 11 Utilities
Reader Status Requests <?> Scanner Status Byte The scanner responds to a status request <?> with a two character hex value, for example <?/22>. To determine the status: 1. Look up the binary conversion in Table 11-5. For example, the first 2 in binary would be 0 0 1 0 as read from binary digits 3 through 0; the second 2 the binary digits 7 through 4 which is also 0 0 1 0. 2. Next, enter your binary values in Table 11-6 in the “Binary” column next to the appropriate bit. Table 11-5 Hex Table 11-6 MS-3 FIS-0003 Laser Scanner Status Value to Binary Bit Binary Scanner Status Conversion 0 Command error (last command received) 0 Binary Command received 1 1 Bit Communication error 2 0 Hex Digits Value Novram read/write error 3 0 7 6 5 4 Motor timeout error OR scanning disabled 4 0 3 2 1 0 Scanner is in a read cycle 5 1 0 0 0 0 0 Software Watch dog reset 6 0 0 0 0 1 1 0 0 1 0 2 Hardware Watch dog reset 7 0 0 0 1 1 3 0 1 0 0 4 3. Under “Binary,” interpret 1s as true and the 0s as not 0 1 0 1 5 true. For example, bit 1 has a 1 in the “Binary” col0 1 1 0 6 umn, indicating “Command Received.” Bit 5 is also a 0 1 1 1 7 1 indicating that the “Scanner is in a read cycle.” 1 0 0 0 8
<?1 > Extended Status The scanner responds to an extended status request <?1> with several fields, for example: <?/F><?1/35338200-12,35-338201-14,476C,33,33>.
9 A B C D E F
1 1 1 1 1 1 1
0 0 0 1 1 1 1
0 1 1 0 0 1 1
1 0 1 0 1 0 1
These represent: the status byte discussed above, the boot part number (35-33820012), the application part number (35-338201-14), the fpga part number (5-55900118), flash checksum (476C), current RAM parameter checksum (33), and flash parameter checksum (33).
<K?> Configuration Command Status Returns the current status of all configuration commands.
MS-3 Laser Scanner User’s Manual
11-19
Page 192
MS-3 Laser E.book Page 20 Monday, August 30, 2004 11:09 AM
Reader Status Requests
11-20
MS-3 Laser Scanner User’s Manual
Page 193
MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM
Appendices
Chapter Contents Appendix A General Specifications ............................................................ A-2 Appendix B Electrical Specifications .......................................................... A-4 Appendix C Connectivity ............................................................................ A-7 Appendix D Serial Configuration Commands........................................... A-13 Appendix E Serial Command Format....................................................... A-16 Appendix F ASCII Table........................................................................... A-18 Appendix G Defaulting/Saving/Resetting ................................................. A-20 Appendix H PDF Symbology.................................................................... A-23 Appendix I Symbol Configuration ............................................................. A-26 Appendix J Object Detector...................................................................... A-28 Appendix K Formulas for Number of Decodes......................................... A-29 Appendix L Operational Tips .................................................................... A-31 Appendix M Interface Standards .............................................................. A-32 Appendix N Multidrop Communications ................................................... A-33 Appendix O Glossary of Terms ................................................................ A-38
MS-3 Laser Scanner User’s Manual
A-1
Page 194
MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM
General Specifications
Appendix A, General Specifications Mechanical Straight Ahead Scanner 0.85” (21.6 mm) 1.75” (44.5 mm) 1.75” (44.5 mm) 2.0 oz. (57 g)
Height: Width: Depth: Weight:
Integral Right Angle Scanner 0.90” (22.9 mm) 2.25” (57.2 mm) 2.40” (61.0 mm) 3.5 oz. (135 g)
.85" (21.6 mm)
Beam
Environmental
Enclosure rating: IP54, category 2 Operating temperature: 0° to 50° C (32° to 122° F) Storage temperature: –30° to 60° (–22° to 140°F) Humidity: Up to 90% (non-condensing) Operating life: 40,000 hours at 25° C
.31" (7.8 mm) 1.75" (44.5 mm) .85" (21.5 mm)
.45" (11.4 mm)
.25" (6.3 mm)
1.25" 1.75" (44.5 mm) (31.7 mm)
2X M3 x 0.5 5.3 mm depth
CE MARK
General Immunity for light industry: EN 55024: 1998 ITE Immunity Standard Radiated and Conducted Emissions of ITE equipment: EN 55022:98, ITE Disturbances.
Figure A-1 MS-3 Laser Scanner
Optics
Laser Emission
Semiconductor, visible laser diode (650 nM nominal); CDRH Class II Scanning Parameters
Options: Single line, fixed raster Scan rate: Adjustable from 300 to 1000 scans/second; default = 500 Scan width angle: >70° Pitch: ±50°; Skew: ±40°; Symbol contrast: 25% min. @ 650 nM
10°
Side .36" (9.1 mm)
.24" (6.1 mm) .63" (16.0 mm)
.90" (22.9 mm)
2X M3x0.5 5mm MIN DEPTH 2.05" (52.1 mm) 2.40" (61.0 mm)
Connector
3 ft. (914 mm) cable terminated with 15-pin D-sub socket connector
2.25" (57.2mm)
1.25" (31.8mm)
Electrical
5 VDC ± 5%, 200 mV p-p max. ripple, 260 mA @ 5 VDC (typ.) Discrete I/O
Trigger Input: 3 to 24V rated (1 mA @ 5 VDC) New Master: 3 to 24V rated (1 mA @ 5 VDC) Outputs (1, 2, 3): 5 V TTL compatible, can sink 10 mA and source 2 mA.
A-2
MS-3 Laser Scanner User’s Manual
2X M3x0.5 5mm MIN DEPTH .45" (11.4mm)
.85" (21.6mm)
Back
Figure A-1 MS-3 Integral Right Angle Laser Scanner
Page 195
MS-3 Laser E.book Page 3 Monday, August 30, 2004 11:09 AM
Chapter Appendices Symbologies
Standard: Code 39, Code 128, I-2/5, Codabar, Code 93, UPC/EAN, Pharmacode Special option: PDF417 FIS Options
Single Line, Raster Low Density, High Density, PDF417 Indicators
Beeper: Good read, Match/Mismatch, Noread, On/Off LEDs: 1 status, 1 power, 5 read performance (representing the percentage of decodes). LED Power Ready/80% GD/RD/100%
State Green On Amber On Amber On
Safety Certifications
FCC, UL/cUL, CE, BSMI ISO 9001:2000 Cert. No. 03-1212 Product specifications are given for typical performance at 23°C (74°F) using grade A symbols. Some performance characteristics may vary at high temperatures or other environmental extremes. © 2006 Microscan Systems, Inc. Specifications subject to change.
Status Scanner has power Scanner in read cycle Good read
Read Ranges
Table A-1 MS-3 Laser High Density Ranges
High Density cm 5 in.
2
0 1
5 1
0
Narrowbar-width
5
2 10
.010" .254 mm
0033" (.076 mm) .005" (.127 mm) .0075" (.191 mm) .010" (.254 mm)
4 3
.0075" .191 mm
2
5
1 .0033" .084 mm
.005" .127 mm cm in. Range
High Density 2.3" to 2.6" (58 to 66 mm) 2" to 3.1" (51 to 79 mm) 1.7" to 3.7" (43 to 94 mm) 1.5 " to 4" (38 to 102 mm)
Low Density cm
10 5 in.
5
0 0
5
10 5 25
10
Narrow-barwidth
20 .020" .508 mm
.010" .254 mm
.015" 15 .381 mm .0075" .191 mm
Table A-2 MS-3 Laser Low Density Ranges
5 10
5
.0075" (.191 mm) .010" (.254 mm) .015" (.381 mm) .020" (.508 mm)
Low Density 3" to 6" (76 to 152 mm) 2 " to 7" (51 to 178 mm) 2" to 8" (51 to 203 mm) 2" to 10" (51 to 254 mm)
cm in. Range
MS-3 Laser Scanner User’s Manual
A-3
Page 196
MS-3 Laser E.book Page 4 Monday, August 30, 2004 11:09 AM
Electrical Specifications
Appendix B, Electrical Specifications Maximum Operating Power: 2 Watts Power Input: 5 VDC ± 5%, 200 mV p-p max. ripple, 260mA @ 5 VDC (typ.) Trigger, New Master Inputs: 3 to 24 V rated, 1 mA @ 5 VDC Outputs (1, 2, 3): 5 V TTL compatible, can sink 10 mA and source 2 mA
Scanner Pin Assignments Table A-3 MS-3 Laser Connector, 15-pin Socket Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Host RS232
Host & Aux Host RS232 RS422/485 Power +5 VDC TxD TxD TxD (–) RxD RxD RxD (–) Power/Signal ground NC RTS Aux TxD TxD (+) Output 1 TTLa Default configuration (NPN) Trigger (NPN) CTS Aux RxD RxD (+) Output 3 TTLa New master pin (NPN) Chassis ground Output 2 TTLa NC a. Can sink 10 mA and source 2 mA.
A-4
MS-3 Laser Scanner User’s Manual
In/ Out In Out In
5
10
Out
15
11 6
1
Out
In In In Out In Out
Caution: • Be sure all cables are connected BEFORE applying power. • Always power down BEFORE
Page 197
MS-3 Laser E.book Page 5 Monday, August 30, 2004 11:09 AM
Chapter Appendices
Direct Input/Output Scanner Diagrams Trigger Input Example Trigger, New Master Inputs: 3 to 24 V rated, 1 mA @ 5 VDC Scanner
Source V
+5VDC
3-24V
Pin 9 (trigger) Source Signal
Output Examples Outputs (1, 2, 3): 5 V TTL compatible, can sink 10 mA and source 2 mA Target
Scanner
+VDC +5VDC RELAY
Pins 7,11,14 (outputs)
Target (PLC, PC, Light Stack, etc.)
Scanner
+VDC
+5VDC Pins 7,11,14 (outputs)
Signal
MS-3 Laser Scanner User’s Manual
A-5
Page 198
MS-3 Laser E.book Page 6 Monday, August 30, 2004 11:09 AM
Electrical Specifications
Optoisolator Trigger Inputs for IC-331 Trigger inputs can be fully isolated pulses as NPN circuits. Minimum
Maximum
VIN-HIGH/IIN-HIGH 4.5 V/ 3.0 mA
V/ 23 mA
VIN-LOW/IIN-LOW
0 V/0 mA
2 .0 V/1 mA
Pulse Widthmin
48 µS
Input (+) I load Input (–)
Input Examples Fully Optoisolated
+V
Isolated Scanner V CC
NPN Source (trigger only)
Isolated Scanner
PNP Source
V CC
+V Input (+)
Signal Input (+)
Input (–)
Input (–)
Signal
Not Optoisolated Non-isolated Scanner
PNP Source +V
V CC
V CC
Power (+) Input (+)
Signal
NPN Source (trigger only)
Non-isolated Scanner Power (+)
+V
Input (+) Input (–)
Input (–) Power ground Power ground
A-6
MS-3 Laser Scanner User’s Manual
Signal
Page 199
MS-3 Laser E.book Page 7 Monday, August 30, 2004 11:09 AM
Chapter Appendices
Appendix C, Connectivity Standalone Setup with IC-332 and IB-131
1
2 3
4 5
6
Network
Scanner
Host
In this configuration the IC-332 transforms incoming 10 to 28 VDC to 5VDC for the MS-3 scanner’s use. • (1) MS-3 laser scanner. • (2) IC-332 interface converter, FIS-0001-0035G. • (3) IB-131 Interface box, 99-000018-01. • (4) Host computer. • (5) Null modem configuration cable, 61-300026-03, DB-25 plug to DB-9 socket, 6 ft. • (6) Power supply 97-100004-15 (90-264 VAC, 24VDC).
7
Figure A-2 MS-3/IB-131 Typical Setup
• (7) Optional object detector P/N 99-000017-01 is shown here.
IC-332 Interface Converter 5
1
6 (plug)
15
“SCANNER” connector to MS-3 (with fixed nuts). See Figure A-3, IC-332 SCANNER Pinouts
3.08" (78.2 mm)
1
5
10 (plug) 15
“EXTERNAL” Connector to IB-131 (with thumbscrews). See Figure A-4, IC-332 EXTERNAL Pinouts (to IB131)
MS-3 Laser Scanner User’s Manual
A-7
Page 200
MS-3 Laser E.book Page 8 Monday, August 30, 2004 11:09 AM
Connectivity Figure A-3 IC-332 SCANNER Pinouts Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Figure A-4 IC-332 EXTERNAL Pinouts (to IB-131)
Host 232
In/Out
Power + 5 VDC TXD RXD Power/Signal Ground NC RTS Output 1 TTL Default Configuration Trigger CTS Output 3 TTL New Master (NPN) Chassis Ground Output 2 TTL NC
Out In Out
In In Out Out Out In Out In
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Host 232
In/Out
Power + 10 to 28 VDC TXD RXD Power/Signal Ground Trigger (–) RTS Output 1 (+) Default Configuration Trigger (+) CTS Output 3 (+) New Master (+) Chassis Ground Output 2 (+) Output 1, 2, 3 (–)
In Out In
In Out Out In In In In Out Out
IB-131 Interface The IB-131 interface simplifies connecting to the scanner by providing separate ports for the host, power supply, trigger and network. The network port is used for multidrop or daisy chain configurations. See the following pages for configuration diagrams and a
A-8
MS-3 Laser Scanner User’s Manual