Page 41

Chapter

Symbologies

4 Chapter Contents Symbologies by ESP ...............................................................................4-2 Symbologies by Serial Command............................................................4-3 Code 39 ...................................................................................................4-4 Code 128/EAN .........................................................................................4-6 Interleaved 2 of 5 .....................................................................................4-7 Codabar .................................................................................................4-10 UPC/EAN ...............................................................................................4-12 Code 93 .................................................................................................4-15 Industrial 2 of 5 ......................................................................................4-16 Symbol Length #2 (Industrial 2 of 5) ......................................................4-18 MSI Code ...............................................................................................4-19 Plessey Code.........................................................................................4-20 RSS Expanded ......................................................................................4-21 RSS Limited ...........................................................................................4-22 RSS-14 ..................................................................................................4-23 Symbology ID ........................................................................................4-24

This section describes the various symbol types that can be read and decoded by the reader. Code 39 is enabled by default. See http://www.aimglobal.org/standards/aimpubs.asp for additional information about symbologies. Note: When assigning characters in user-defined fields, the characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

MS-3 CCD Reader User’s Manual

4-1

Page 42

Symbologies by ESP

Symbologies by ESP

Click this Button to bring up the Symbologies menu

To open nested options, single-click the +. To change a setting, double-click the setting and use your curser to scroll through the options.

4-2

MS-3 CCD Reader User’s Manual

Page 43

Chapter 4 Symbologies

Symbologies by Serial Command Command Title Code 39 Code 128/EAN Interleaved 2 of 5 Codabar UPC/EAN Code 93 Industrial 2 of 5 MSI Code Plessey RSS Expanded RSS Limited RSS-14 Symbology ID

Format <K470, status,check digit status,check digit output status,unused,unused,minimum symbol length,full ASCII set> <K474, status,unused,minimum symbol length,1,1,unused,application record separator character> <K472,status,check digit status,check digit output status,symbol length #1,symbol length #2> <K471,status,unused,start & stop output status,unused,symbol length status,symbol length,check digit type,check digit status,check digit output status> <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplemental status,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13, UPC-E as A,EAN-8 as EAN-13> <K475,status,unused,minimum length> <K488, status,check digit status,check digit output status,format,symbol length #1,symbol length #2> <K486,status,check digit mode,check digit output status,unused,minimum symbol length> <K487, status,check digit output status,unused,minimum symbol length> <K484, status> <K483,status> <K482, status> <K450,0,symbology identifier status>

MS-3 CCD Reader User’s Manual

4-3

Page 44

Code 39

Code 39 Usage:

Code 39 is considered the standard for non-retail bar code applications.

Definition:

An alphanumeric symbol with unique start/stop symbol patterns, composed of 9 black and white elements per character, of which 3 are wide.

Code 39 Status Serial Cmd:

<K470, status,check digit status,check digit output status,unused,unused,minimum symbol length,full ASCII set>

Default:

Enabled Note: This is the only symbol type enabled by default.

Options:

0 = Disabled

1 = Enabled

Check Digit Status (Code 39) Serial Cmd:

<K470,code 39 status,check digit status,check digit output status,unused,unused,minimum symbol length,full ASCII set>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Check Digit Output (Code 39) Usage:

Check Digit Output Status, added to the symbol, provides additional security.

Definition:

When enabled, the check digit character is read and sent along with the symbol data. When disabled, symbol data is sent without the check digit. Note: When in Single symbol mode and Check Digit Output Status and an External or Serial trigger option enabled, an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle.

Serial Cmd:

<K470, status,check digit status,check digit output status,unused,unused,minimum symbol length,full ASCII set>

Default:

Disabled

Options:

0 = Disabled

4-4

1 = Enabled

MS-3 CCD Reader User’s Manual

Page 45

Chapter 4 Symbologies

Minimum Symbol Length (Code 39) Usage:

Minimum symbol Length helps prevent truncations and increases data integrity by ensuring that a minimum symbol length will be accepted.

Definition:

Specifies a number of characters that the reader will recognize, including start and stop and check digit characters. The reader ignores any symbol smaller than the specified length.

Serial Cmd:

<K470, status,check digit status,check digit output status,unused,unused,minimum symbol length,full ASCII set>

Default:

0

Options:

0 to 32

Important: When setting Symbol Length to any number other than 0, add 1 to account for a check digit. For example, if your symbol has 3 characters, set Symbol Length to 4.

Full ASCII Set (Code 39) Usage:

Default:

Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) User must know in advance whether or not to use Full ASCII Set option. Since Full ASCII Set requires two symbol words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign and percent symbol. When Full ASCII Set is enabled, the reader can read the full ASCII character set, from 0 to 255. <K470,status,check digit status,check digit output status,unused,unused,minimum symbol length,full ASCII set> Disabled

Options:

0 = Disabled

Definition:

Serial Cmd:

1 = Enabled

MS-3 CCD Reader User’s Manual

4-5

Page 46

Code 128/EAN

Code 128/EAN Usage:

Code 128/EAN is useful in applications with tight spots and high security needs.

Definition:

A very dense alphanumeric symbology. It encodes all 128 ASCII characters; it is continuous, has variable length, and uses multiple element widths measured edge to edge.

Code 128/EAN Status Serial Cmd:

<K474, status,unused,minimum symbol length,1,1,unused,application record separator character>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Note: Status includes both Code 128 and EAN. Note: Fixed Symbol Length Status must be enabled for Symbol Length to take effect.

Minimum Symbol Length (Code 128/EAN) Note: Minimum Symbol Length is enabled by setting the default to any value other than zero. Usage:

Minimum Symbol Length helps prevent truncations and increases data integrity by ensuring that only minimum length symbols will be accepted.

Definition:

Specifies a number of characters that the reader will recognize, including start and stop and check digit characters. The reader ignores any symbol smaller than the specified length.

Serial Cmd:

<K474, status,unused,minimum symbol length,1,1,unused,application record separator character>

Default:

0 (0 = any length)

Options:

0 to 32

Application Record Separator Character (Code 128/EAN) Note: Application Record Separator Character Status is enabled by setting the parameter to any value other than a null. Definition: Serial Cmd: Default: Options:

4-6

Allows the user to define an ASCII character as an application record separator. <K474, status,unused,minimum symbol length,1,1,unused,application record separator character> Null (0x00) (disabled, no separator output) User Defined ASCII character

MS-3 CCD Reader User’s Manual

Page 47

Chapter 4 Symbologies

Interleaved 2 of 5 Usage:

It is has been popular because it is the most dense symbol for printing numeric characters less than 10 characters in length; however Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation.

Definition:

A dense, continuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check digit is highly recommended.) Important: You must set Symbol Length in order to decode I 2/5 symbols.

Interleaved 2 of 5 Status Serial Cmd:

<K472, status,check digit status,check digit output status,symbol length #1,symbol length #2>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Check Digit Status (Interleaved 2 of 5) Usage:

It is typically not used but can be enabled for additional security in applications where the host requires redundant check digit verification.

Definition:

An error correcting routine in which the check digit character is added.

Serial Cmd:

<K472, status,check digit status,check digit output status,symbol length #1,symbol length #2>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Check Digit Output Status (Interleaved 2 of 5) Definition:

When enabled, a check digit character is sent along with the bar symbol data for added data security.

Serial Cmd:

<K472, status,check digit status,check digit output status,symbol length #1,symbol length #2>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

MS-3 CCD Reader User’s Manual

4-7

Page 48

Interleaved 2 of 5

Symbol Length #1 (Interleaved 2 of 5) Usage:

With Industrial 2/5, two symbol lengths can be defined. When using only one symbol length in an application, setting Symbol Length #2 to 0 (zero) to ensure data integrity is recommended.

Definition:

Specifies a number of characters that the reader will recognize, including start and stop and check digit characters. The reader ignores any symbol smaller than the specified length. Because Industrial 2/5 is a continuous symbol, it is prone to substitution errors. Hence, a symbol length must be defined and a bar symbol must contain an even number of digits. Note: If Range Mode is set to Enable, the settings for Symbol Length #1 and Symbol Length #2 will define the range of symbol lengths that can be decoded.

Serial Cmd:

<K472, status,check digit status,check digit output status,symbol length #1,symbol length #2>

Default:

6

Options:

0 to 32 Rules: Both Symbol Length #1 and Symbol Length #2 must be sent at the same time for the command to take effect. To set for any length, Length #1 and Length #2 must both equal zero. To set for minimum length, both Length #1 and Length #2 must be equal to each other and be any number other than zero. To set for a fixed length, Length #1 and Length #2 must not be equal to each other and must both be greater than zero.

4-8

MS-3 CCD Reader User’s Manual

Page 49

Chapter 4 Symbologies

Symbol Length #2 (Interleaved 2 of 5) Usage:

If using a second symbol, a zero or any even symbol length in the option range may be specified. If not using a second symbol, set Symbol Length #2 to 0 to ensure data integrity.

Definition:

Specifies a number of characters that the reader will recognize, including start and stop and check digit characters. The reader ignores any symbol smaller than the specified length. Note: If Range Mode is set to Enable, the settings for Symbol Length #1 and Symbol Length #2 will define the range of symbol lengths that can be decoded.

Serial Cmd:

<K472, status,check digit status,check digit output status,symbol length #1,symbol length #2>

Default:

10

Options:

0 to 32 Rules: See “Symbol Length #1 (Interleaved 2 of 5)” for rules for saving.

Important: When setting Symbol Length to any number other than 0, add 1 to account for a reserved space. For example, if your symbol has 3 characters, set Symbol Length to 4.

MS-3 CCD Reader User’s Manual

4-9

Page 50

Codabar

Codabar Usage:

Used in photo-finishing and library applications. Formerly used in some medical applications but not typically used in newer applications.

Definition:

Codabar is a 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths.

Codabar Status Serial Cmd:

<K471, status,unused,start & stop match output status,unused,symbol length status,symbol length,check digit status,check digit output status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Start & Stop Output Status (Codabar) Usage:

Used to verify matching.

Definition:

Causes the start and stop characters to be transmitted with symbol data.

Serial Cmd:

<K471, status,unused,start & stop output status,unused,symbol length status,symbol length,check digit status,check digit output status>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

Symbol Length Status (Codabar) Usage:

Restricting symbol lengths can help prevent truncations and increase data integrity by ensuring that only one or a defined range of symbol lengths will be accepted.

Definition:

When set to Fixed, the reader will check the symbol length against the Symbol Length field. When set to Any/Minimum, any length is considered a valid symbol. The following rules apply:

Serial Cmd:

<K471, status,unused,start & stop output status,unused,symbol length status,symbol length,check digit status,check digit output status>

Default:

Any/Minimum

Options:

0 = Any/Minimum

4-10

MS-3 CCD Reader User’s Manual

1 = Fixed