Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 11

MS-3 CCD Reader User's Manual, pages 51 to 60

Pages 51 to 60 of 106

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-3

Page 51

Chapter 4 Symbologies

Symbol Length (Codabar) Definition:

Specifies a number of characters that the reader will recognize, including start and stop and check digit characters. The reader ignores any symbol smaller than the specified length. Important Notes: • When setting Symbol Length to any number other than zero, add 2 to account for reserved spaces. For example, if your symbol has 3 characters, set Symbol Length to 5. • If Symbol Length is set to zero (0) and Symbol Length Status is set to Any/Minimum, all symbol lengths are decoded.

Serial Cmd:

<K471, status,unused,start & stop output status,unused,symbol length status, symbol length,check digit status,check digit output status>

Default:

6

Options:

0 to 32 (Zero equals any length.)

Note: Because of symbology limitations, setting Symbol Length to any number less than four will produce undetermined results.

Check Digit Status (Codabar) Usage:

Modulus 16 is used in the photo-finishing market.

Definition:

Allows the user to select the check digit type Codabar will use.

Serial Cmd:

<K471, status,unused,start & stop output status,unused,symbol length status, symbol length,check digit status,check digit output status>

Default:

Disabled

Options:

0 = Disabled

1 = Enable (Modulus 16)

Check Digit Output Status (Codabar) Usage:

For additional security a check digit can be added to the symbol.

Definition:

When enabled, the check digit character is sent along with the symbol data. When disabled, symbol data is sent without the check digit.

Serial Cmd:

<K471, status,unused,start & stop output status,unused,symbol length status, symbol length,check digit type,check digit status,check digit output status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

MS-3 CCD Reader User’s Manual

4-11

Page 52

UPC/EAN

UPC/EAN Usage: Definition:

Used primarily in POS application in the retail industry. UPC (Universal Product Code) is a fixed length numeric, continuous symbology. UPC can have two- or five-digit supplemental symbol data following the normal symbol. The U.P.C., Version A (U.P.C., A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character.

UPC-A Status Serial Cmd: Default:

<K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13,UPC-E as A,EAN-8 as EAN-13> Enabled

Options:

0 = Disabled

1 = Enabled

UPC-E Status Serial Cmd: Default:

<K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13,UPC-E as A,EAN-8 as EAN-13> Enabled

Options:

0 = Disabled

1 = Enabled

EAN-8 Status Serial Cmd: Default:

<K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status,UPC-A as EAN-13,UPC-E as A,EAN-8 as EAN-13> Enabled

Options:

0 = Disabled

1 = Enabled

EAN-13 Status Serial Cmd: Default:

<K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13, UPC-E as A,EAN-8 as EAN-13> Enabled

Options:

0 = Disabled

4-12

1 = Enabled

MS-3 CCD Reader User’s Manual

Page 53

Chapter 4 Symbologies

Supplementals Required (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:

Reads Supplementals typically used in publications and documentation. A supplemental is a 2 or 5 digit symbol appended to the main symbol. When set to Enabled (Required), the reader reads supplemental symbol data that has been appended to the standard UPC or EAN codes. <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13, UPC-E as A,EAN-8 as EAN-13> Disabled (Not Required) 0 = Not required, but output if decoded 1 = Enabled (Required)

Supplemental 2 Status Default: Serial Cmd:

Disabled <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13, UPC-E as A,EAN-8 as EAN-13>

Options:

0 = Disabled

1 = Enabled

Supplemental 5 Status Default: Serial Cmd:

Disabled <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13,UPC-E as A,EAN-8 as EAN-13>

Options:

0 = Disabled

1 = Enabled

MS-3 CCD Reader User’s Manual

4-13

Page 54

UPC/EAN

Output Format UPC-A as EAN-13 Definition Serial Cmd: Default:

UPC-A will be transmitted as EAN-13 <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13,UPC-E as A,EAN-8 as EAN-13> Enabled

Options:

0 = Disabled

1 = Enabled

UPC-E as UPC-A Definition Serial Cmd: Default:

UPC-E will be transmitted as UPC-A <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13 UPC-E as A,EAN-8 as EAN-13> Disabled

Options:

0 = Disabled

1 = Enabled

EAN-8 as EAN-13 Definition Serial Cmd: Default:

EAN-8 will be transmitted as EAN-13 <K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supplementals required,supplemental 2 status,supplemental 5 status, UPC-A as EAN-13,UPC-E as A,EAN-8 as EAN-13> Disabled

Options:

0 = Disabled

4-14

1 = Enabled

MS-3 CCD Reader User’s Manual

Page 55

Chapter 4 Symbologies

Code 93 Usage: Definition:

Used occasionally in clinical industry. Code 93 is a variable length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces.

Code 93 Status Serial Cmd: Default:

<K475, status,unused,minimum length> Disabled

Options:

0 = Disabled

1 = Enabled

Minimum Symbol Length (Code 93) Usage: Definition:

Serial Cmd: Default: Options:

Minimum Symbol Length helps prevent truncations and increases data integrity by ensuring that a minimum symbol length will be accepted. Specifies the minimum number of characters that the reader will recognize (this does not include start and stop and check digit characters). The reader ignores any symbol smaller than the specified length. Important: When setting Symbol Length to any number other than zero, add 1 to account for a reserved space. For example, if your symbol has 3 characters, set Symbol Length to 4. <K475, status,unused,minimum symbol length> 10 0 to 32

MS-3 CCD Reader User’s Manual

4-15

Page 56

Industrial 2 of 5

Industrial 2 of 5 Usage:

Also called “Standard 2 of 5,” it has been used widely in the photofinishing and warehouse sorting industries, as well as sequentially numbering airline tickets. Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation.

Definition:

A non-interleaved, low-density, continuous, self-checking numeric symbology that does not require a checksum. The encoding method is essentially the same as Interleaved 2 of 5 except that with Industrial spaces are fixed width and used only to separate the bars. Interleaved 2 of 5 allows information to be encoded in both the bars and spaces. (A check digit is highly recommended.) Important: You must set Symbol Length in order to decode Industrial 2/5 symbols.

Industrial 2 of 5 Status Serial Cmd:

<K488, status,check digit status,check digit output status,format,symbol length #1,symbol length #2>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Check Digit Status (Industrial 2 of 5) Usage:

It is typically not used but can be enabled for additional security in applications where the host requires redundant check digit verification.

Definition:

An error correcting routine in which the check digit character is added.

Serial Cmd:

<K488, status,check digit status,check digit output status,format, symbol length #1,symbol length #2>

Default:

Disabled

Check Digit Output Status (Industrial 2 of 5) Definition:

When enabled, a check digit character is sent along with the bar symbol data for added data security.

Serial Cmd:

<K488, status,check digit status,check digit output status,format, symbol length #1,symbol length #2>

Default:

Disabled

Options:

0 = Disabled

4-16

1 = Enabled

MS-3 CCD Reader User’s Manual

Page 57

Chapter 4 Symbologies

Format (Industrial 2 of 5) Definition:

Sets the number of start and stop characters

Serial Cmd:

<K488, status,check digit status,check digit output status,format, symbol length #1,symbol length #2>

Default:

3 start/3 stop

Options:

0 = 3 start/3 stop

1 = 2 start/2 stop

Symbol Length #1 (Industrial 2 of 5) Usage:

With Industrial 2/5, two symbol lengths can be defined. When using only one symbol length in an application, setting Symbol Length #2 to 0 (zero) to ensure data integrity is recommended.

Definition:

Specifies a number of characters that the reader will recognize, including a check digit character. Allows user to define the symbol length as any length, a minimum length, or a fixed length.

Serial Cmd:

<K488, status,check digit status,check digit output status,format,symbol length #1,symbol length #2>

Serial Cmd:

<K472, status,check digit status,check digit output status,format, symbol length #1,symbol length #2>

Default:

10

Options:

0 to 32 Rules: • Both Symbol Length #1 and Symbol Length #2 must be saved at the same time for the command to take effect. • To set for any length, Length #1 and Length #2 must both equal zero. • To set for minimum length, both Symbol Length #1 and Symbol Length #2 must be equal to each other and be any number other than zero. • To set fixed lengths, Length #1 and Length #2 must not be equal to each other and either one greater than zero.

MS-3 CCD Reader User’s Manual

4-17

Page 58

Symbol Length #2 (Industrial 2 of 5)

Symbol Length #2 (Industrial 2 of 5) Usage:

If using a second symbol, a zero or any symbol length from 0 to 32 may be specified. If not using a second symbol, set Symbol Length #2 to 0 to ensure data integrity.

Definition:

Specifies a number of characters that the reader will recognize, including a check digit character. Allows user to define a second symbol length for Industrial 2/5.

Serial Cmd:

<K488, status,check digit status,check digit output status,format,symbol length #1,symbol length #2>

Default:

6

Options:

0 to 32 See “Symbol Length #1 (Industrial 2 of 5)”for rules for saving.

4-18

MS-3 CCD Reader User’s Manual

Page 59

Chapter 4 Symbologies

MSI Code Usage: Definition:

Used in retail and inventory markets. A variation of Plessey, MSI is a numeric, continuous code, with each character consisting of four bits in a binary format.

MSI Status Serial Cmd: Default:

<K486, status,check digit mode,check digit output status,unused,minimum symbol length> Disabled

Options:

0 = Disabled

1 = Enabled

Check Digit Mode (MSI Code) Serial Cmd: Default:

<K486, status,check digit mode,check digit output status,unused,minimum symbol length> Mod10

Check Digit Output Status (MSI Code) Serial Cmd: Default:

<K486, status,check digit mode,check digit output status,unused,minimum symbol length> Enabled

Options:

0 = Disabled

1 = Enabled

Minimum Symbol Length (MSI Code) Definition: Serial Cmd: Default: Options:

Specifies a number of characters that the reader will recognize, including a check digit character. <K486, status,check digit mode,check digit output status,unused,minimum symbol length> 6 0 to 32 Zero equals any length. 1 through 32 sets a minimum length.

MS-3 CCD Reader User’s Manual

4-19

Page 60

Plessey Code

Plessey Code Usage: Definition:

First developed in March 1971, it has been used extensively in libraries, retail, production, and stock control. Plessey Code consists of pairs of wide/narrow bars that represent 1s and 0s which, taken in units of 12, define hexidecimal characters.

Plessey Status Serial Cmd: Default:

<K487, status,check digit output status,unused,minimum symbol length> Disabled

Options:

0 = Disabled

1 = Enabled

Check Digit Output Status (Plessey Code) Serial Cmd: Default:

<K487, status,check digit output status,unused,minimum symbol length> Disabled

Options:

0 = Disabled

1 = Enabled

Minimum Symbol Length (Plessey Code) Definition:

Default:

Specifies a number of characters that the reader will recognize, including a check digit character. <K487, status,check digit output status,unused,minimum symbol length> 0

Options:

0 to 32

Serial Cmd:

4-20

MS-3 CCD Reader User’s Manual