Page 21
Chapter 2 Communications
Point-to-Point with RTS/CTS Usage:
A reader initiates a data transfer with an RTS (request-to-send) transmission. The host, when ready, responds with a CTS (clear-to-send) and the data is transmitted. CTS and RTS signals are transmitted over two dedicated wires as defined in the RS-232 standard. Used only with RS232.
Definition:
Point-to-Point with RTS/CTS (request-to-send/clear-to-send) is a simple hardware handshaking protocol that allows a reader to initiate data transfers to the host.
Serial Cmd:
<K140,1>
Note: When <K140,1> is sent, RTS/CTS takes effect without a save command. Note: The host must allow every chance possible for the reader to output. If CTS is not active for a long period of time, loss of data will occur. Note: The reader cannot respond to multiple commands whenever CTS is inactive. Multiple commands will be buffered, but if a command generates a response to the host, successive commands will not be processed until the response is output. This affects both K commands and operational commands, including the reset commands <A> <Z>, and <Zrd>.
MS-3 CCD Reader User’s Manual
2-5
Page 22
Preamble
Preamble Preamble Status Usage:
Useful for identifying and controlling incoming data. For example, defining the preamble as a carriage return and a line feed causes each decoded message to be displayed of on its own line.
Definition:
Defines a one to four character data string that can be added to the front of the decoded data.
Serial Cmd:
<K141, preamble status,preamble character(s)>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled (within any protocol)
Note: When setting to Enabled, the preamble string must also be sent in the same command.
Preamble Characters Serial Cmd:
<K141, preamble status,preamble characters>
Default:
^M corresponds to: carriage return/null/null/null.
Options:
Up to four user-defined ASCII characters, including control characters.
To enter control characters within a serial command, hold down the control key while typing the desired character. Example: <K141,1,CNTL-m> to enter ^M.
2-6
MS-3 CCD Reader User’s Manual
Page 23
Chapter 2 Communications
Postamble Postamble Status Usage:
Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed of on its own line.
Definition:
Defines a one to four character data string that can be added to the end of the decoded data.
Serial Cmd:
<K142, status,postamble character(s)>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled (within any protocol)
Note: When setting to Enabled, the postamble string must also be sent in the same command.
Postamble Characters Serial Cmd:
<K142, status,postamble characters>
Default:
^M^J. Corresponds to carriage return/line feed/null/null, as displayed in the menu.
Options:
Up to four user-defined ASCII characters, including control characters.
To enter control characters within a serial command, hold down the control key while typing the desired character. Example: <K142,CNTL-m CNTL-j> to enter ^M^J.
MS-3 CCD Reader User’s Manual
2-7
Page 24
Postamble
2-8
MS-3 CCD Reader User’s Manual
Page 25
Chapter
Read Cycle
3 Chapter Contents Read Cycle by ESP .................................................................................3-2 Read Cycle by Serial Command..............................................................3-2 Read Cycle Differences in the MS-3 CCD ...............................................3-3 Number of Symbols .................................................................................3-4 Time Between Identical Decodes ............................................................3-5 No Decode Timeout ...............................................................................3-11 Decodes Before Output .........................................................................3-12 Noread Message ...................................................................................3-13 Reader Setup.........................................................................................3-14
After you’ve established communications and completed basic read rate testing, you will need to address the spatial and timing parameters associated with your application. In a typical operation a bar coded item moves along a line past a reader. A trigger or timer activates a read cycle during which the reader actively searches for symbols. You will need to decide how to initiate the read cycle and how and when to end it. Note: When assigning characters in user-defined fields, the characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands. Note on Serial Commands: To preserve continuity with other Microscan products, some serial configuration commands may include 0s (zeros) or 1s as placeholders. In order for a these commands to be implemented, the parameter values or a comma must be included.
MS-3 CCD Reader User’s Manual
3-1
Page 26
Read Cycle by ESP
Read Cycle by ESP
Click this Button to bring up the Read Cycle menu
To open nested options, single-click the +.
To change a setting, double-click the setting and use your curser to scroll through the options.
Read Cycle by Serial Command Command Title Number of Symbols Time Between Identical Decodes Trigger Mode Serial Trigger Character Start Character Stop Character No Decode Timeout Decodes Before Timeout Noread Message Automatic Gain Control Lighting Intensity Filter Mode
3-2
Format <K222,number of symbols> <K503,TBID> <K200,trigger mode> <K201,serial trigger character> <K229,start trigger character> <K230,stop trigger character> <K220,no decode timeout> <K221,number before output> <K714,status,noread message> <K522,shutter speed,minimum speed,maximum speed> <K523,percent lighting> <K524,filter mode,filter list>
MS-3 CCD Reader User’s Manual
Page 27
Chapter 3 Read Cycle
Read Cycle Differences in the MS-3 CCD Important: With the MS-3 CCD, symbol data is output as soon as it is decoded. There is no “end of read cycle” option. Because of this limitation, multisymbol operations can only be emulated by controlling the read cycle duration and the time allowed between identical consecutive decodes. In read cycle timing, the MS-3 CCD differs from standard Microscan readers in the following ways: 1. In Single symbol mode, a read cycle ends only on a decode, falling trigger or a timeout. 2. In Multiple symbol mode, the read cycle begins upon a triggered event, but starts over after any symbol has been decoded. 3. There is no “new trigger” feature. 4. There is no timeout for level trigger read cycle mode. In general, read cycle timeout and end of read cycle outputs are determined by “Trigger Mode”, “No Decode Timeout”, and “Time Between Identical Decodes”.
MS-3 CCD Reader User’s Manual
3-3
Page 28
Number of Symbols
Number of Symbols Note: Multiple symbol scanning is different in the MS-3 CCD from other Microscan products in that the multisymbol operation is emulated by setting timeout conditions and timing between identical decodes. Usage:
Commonly used where a shipping symbol contains individual symbols for part number, quantity, etc.
Definition:
Determines whether a single symbol or multiple symbols can be read and decoded in a single read cycle.
Conditions:
The following conditions apply: 1. When Number of Symbols is set to Single, the read cycle ends when one symbol is decoded and output. 2. When Number of Symbols is set to Multiple, all decoded symbol data (for both the same and different symbols) are output while the read cycle is active and/or no timeout has occurred. 3. If set to Multiple and TBIDa is less than the decode time (typically about 4 mS), the same symbol can be output multiple times.
Serial Cmd:
<K222, number of symbols>
Default:
Single
Options:
0 = Multiple
1 = Single a. Time Between Identical Decodes
3-4
MS-3 CCD Reader User’s Manual
Page 29
Chapter 3 Read Cycle
Time Between Identical Decodes Usage:
Can be used to prevents repetition of decode outputs. Also useful for emulating multisymbol operations. When used in conjunction with Number of Symbols set to Multiple, Timing Between Identical Decodes can be set so that more than one symbol can be read within a read cycle.
Definition:
Sets the length of time that the reader will wait before allowing a symbol that has been output from outputting again.
Serial Cmd:
<K503,TBID>
Default:
0
Options:
0 to 2550 mS.
MS-3 CCD Reader User’s Manual
3-5
Page 30
Time Between Identical Decodes
Trigger Trigger Mode Definition:
The type of trigger event that will initiate the read cycle.
Serial Cmd:
<K200,trigger mode>
Default:
Continuous
Options:
0 = Continuous Read See “Continuous Read 1 Emulation” on page 3-6. 2 = External Level 3 = External Edge 4 = Serial Data 5 = Serial Data & External Edge 6 = Custom (custom configured via symbol setup)
Continuous Read Usage:
Continuous Read is useful in testing symbol readability or reader functions. It is not recommended for normal operations.
Definition:
In Continuous Read, trigger input options are disabled, the reader is always in the read cycle, and it will attempt to decode and output every scan crossing a symbol.
Serial Cmd:
<K200, 0>
Continuous Read 1 Emulation Usage:
Continuous Read 1 Emulation can be useful in applications where it is not feasible to use a trigger and all succeeding symbols contain different information. It is also effective in applications where the objects are hand-presented.
Definition:
In Continuous Read 1 Emulation the reader triggers whenever it decodes a new symbol.
Operation:
Continuous Read 1 is emulated by enabling TBID to any value other than zero and works best if the TBID timeout is longer than the decode time.
Hint:
Set TBID (“Time Between Identical Decodes” on page 3-5) to maximum to ensure enough time for decode to take place.
Caution: In automated environments, Continuous Read 1 Emulation is not recommended because there is no one to verify that a symbol was missed.
3-6
MS-3 CCD Reader User’s Manual