For the Microscan MS-3
Page 11
Chapter 1 Quick Start
Step 2, Install ESP (ESP is short for Easy Setup Program.) With your reader connected to a host computer with Windows operating system, you can use the ESP to configure and control the reader. 1. Insert your Microscan CD into your computer’s CD drive. 2. Launch Setup.exe under ESP and follow the prompts. If downloading from the web: a) Go to http://www.microscan.com/downloadcenter/ b) Enter company information. c) Select ESP and download to your computer hard drive. d) Extract ESP files to a directory of your choice. 3. Note where your ESP.exe file is stored on your hard drive. At the end of the install process, you should see the following icon on your desktop:
4. Click the ESP icon to start the program.
MS-3 CCD Reader User’s Manual
1-3
Page 12
Step 3, Select Reader Model When you start the program, the following menu will appear.
Note: If you need to select another model later, click the Switch Model button. 1. Select MS-3 CCD from the menu and click OK. If you do not want to make this selection every time you load ESP, uncheck Show this window at Startup. 2. Select the default name, for example MS-3 CCD-1, or type in a file name of your choice and click OK. 3. Click Yes when the connect to the reader dialog appears.
1-4
MS-3 CCD Reader User’s Manual
Page 13
Chapter 1 Quick Start
Step 4, Autoconnect 1. In the Connecting to... dialog, if your communications port is not the default COM1, use the pull down arrow to change your communications port.
2. Click the Start button. When connected, the CONNECTED message will appear in a green box in the status bar on the bottom right of the dialog.
3. If connection fails, enable a different Com port, check connections, and try again. Tip: If you do not see either the CONNECTED or DISCONNECTED message at the bottom of your dialog, try expanding the ESP window horizontally. Important: When you connect to the reader, the reader’s settings will be loaded into ESP.
MS-3 CCD Reader User’s Manual
1-5
Page 14
Step 5, Position Symbol and Reader Note: Code 39 is the default code type enabled. If you are uncertain as to your symbology type, enable all codes by selecting the Auto Discriminate macro in Terminal mode. 1. Set up a symbol at the scanning distance you are using in your application. (See Figure A-3, MS-3 CCD Read Ranges, on page A- 3.) 2. Avoid bright light or IR light from other sources, including other readers. 3. Pitch symbol or reader slightly to avoid specular reflection, the return of direct, non-diffused light.1 Pitch axis Skew axis
Reader
Bar code symbol Tilt axis
Figure 1-2 Symbol/Reader Position
Note: If using an I 2/5 symbol, verify that the number of characters in the symbol being scanned matches the symbol length enabled for the I 2/5 symbol type. (Default is 10 and 6.)
1. The MS-3 CCD sensor is located directly above the LED illuminators. For this reason, you should avoid tipping symbols back so that the sensor receives direct specular reflection.
1-6
MS-3 CCD Reader User’s Manual
Page 15
Chapter 1 Quick Start
Step 6, Configure the Reader See the succeeding chapters and Appendices to see specific configuration command explanations for both ESP and serial commands.
By ESP To make change reader settings, or to access the utilities or terminal window, click on the App Mode button.
To return to the Setup Mode, click on the Setup Mode button.
By Serial Commands From your terminal program or the terminal screen in ESP, you can enter serial string commands configuration and utility commands as described herein. See “Serial Configuration Commands” on page A-10 and “Summary of Utilities Commands” on page 5-2. Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?> To see all “K” commands, send <K?>. You have 2 choices for saving ESP settings to the reader: • Send, No Save. This saves ESP settings to current memory. • Send and Save. This activates all changes in current memory and saves to the reader for power-on. (Similar to the <Z> command.)
MS-3 CCD Reader User’s Manual
1-7
Page 16
Receiving From the Send/Recv selector select Receive Reader Settings. This is useful if you want to: • Receive (upload) the reader’s settings and save them as a computer file for later retrieval. • Verify that your ESP settings have been saved or that you have not saved any unwanted changes that you or someone else previously made in ESP.
Defaulting When you select Default Current... or Default all ESP... you are only defaulting the ESP settings. To default the reader, see “Defaulting/Saving/Resetting” on page A15 for a more information.
1-8
MS-3 CCD Reader User’s Manual
Page 17
Communications
Chapter
2 Chapter Contents Communications by ESP .........................................................................2-2 Communications By Serial Command .....................................................2-2 Preamble .................................................................................................2-6 Postamble ................................................................................................2-7 With Microscan’s ESP (Easy Setup Program), configuration changes can be made in the ESP menus, then sent and saved to your reader. The user can also send serial commands to the reader via the ESP’s Terminal window. This section includes connecting parameters and options for communicating by the auxiliary port and various interfaces. Note: When assigning characters in user-defined fields, the characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands. Note: Default settings for establishing communications are: Baud = 9600 Parity = Even Stop Bits = One Data Bits = Seven Flow Control = None Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?> To see all “K” commands, send <K?>.
MS-3 CCD Reader User’s Manual
2-1
Page 18
Communications by ESP
Communications by ESP
Click this button to bring up the Communications menu. To change a setting, double-click the setting and use your curser to scroll through the options.
Communications By Serial Command Command Title Host Port Parameters Host Protocol Preamble Postamble
Format <K100,baud,parity,stop bits,data bits> <K140,protocol> <K141,preambole status,preamble> <K142,postamble status,postamble>
Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?> To see all “K” commands, send <K?>.
2-2
MS-3 CCD Reader User’s Manual
Page 19
Chapter 2 Communications
Host Port Connections Baud Rate (host port) Usage:
Can be used to transfer data faster or to match host port settings.
Definition:
The rate at which the reader and host transfer data back and forth.
Serial Cmd:
<K100, baud rate,parity,stop bits,data bits>
Default:
9600
Options:
1 = 1200 4 = 9600
2 = 2400 5 = 19.2 K
3 = 4800 6 = 38.4 K
Note: When running at baud rates less than 19.2 K, some loss of symbol data may occur if the reader approaches its maximum decode rate.
Parity (host port) Usage:
Only changed if necessary to match host setting.
Definition:
An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.
Serial Cmd:
<K100, baud rate,parity,stop bits,data bits>
Default:
Even
Options:
0 = None
1 = Even
2 = Odd
Stop Bits (host port) Usage:
Only changed if necessary to match host setting.
Definition:
One or two bits added to the end of each character to indicate the end of the character.
Serial Cmd:
<K100, baud rate,parity,stop bits,data bits>
Default:
One
Options:
0 = One
1 = Two
Data Bits (host port) Usage:
Only changed if necessary to match host setting.
Definition:
Number of bits in each character.
Serial Cmd:
<K100, baud rate,parity,stop bits,data bits>
Default:
Seven
Options:
0 = Seven
1 = Eight
MS-3 CCD Reader User’s Manual
2-3
Page 20
Host Port Protocol
Host Port Protocol Usage:
In general, the point-to-point protocols will work well in most applications. They require no address and must use RS-232 or RS-422 communications standards.
Definition:
Protocols define the sequence and format in which information is transferred between the reader and the host, or in the case of Multidrop, between readers and a concentrator.
Serial Cmd:
<K140,protocol>
Default:
Point-to-Point
Options:
0 = Point-to-Point 1 = Point-to-Point with RTS/CTS 2 = Point-to-Point with XON/XOFF 3 = Point-to-Point with RTS/CTS & XON/XOFF
4 = Polling Mode D 5 = Multidrop 6 = User Defined 7 = User Defined Multidrop
If selecting one of the options from 0 to 4 (Point-to-Point, Point-toPoint with RTS/CTS, Point-to-Point with XON/XOFF, Point-toPoint with RTS/CTS and XON/XOFF, or Polling Mode D), use the <K140,protocol> format. Option 5 through 7 are special cases and discussed later in this section.
Point-to-Point (standard) Usage:
Used only with RS232 or RS422.
Definition:
Standard Point-to-Point requires no address and sends data to the host whenever it is available, without any request or handshake from the host.
Serial Cmd:
<K140, 0>
2-4
MS-3 CCD Reader User’s Manual