Page 81

output mode: 0 = Pulse 1 = Latch Mode 1 (Unlatch Pin) 2 = Latch Mode 2 (Unlatch Opposite Condition) 3 = Latch Mode 3 (Unlatch Re-enter Read Cycle)

trend analysis mode: 0 = Image Degradation 1 = Mismatch 2 = Noread trigger evaluation period: Any number from 0 - 255 Default is 0

# to output on: Any number from 0 - 255 Default is 0

Output On Allows you to determine the conditions under which a output pulse will be output (high or low depending on polarity) to the host connector. Mismatch or Noread. Sends a pulse when the label’s data does not match that of the master label, or the label is not decoded before the end of the read cycle. Good Match. Sends a pulse when the decoded label matches the master label. Noread. Sends a pulse when the label’s data is not decoded before the end of the read cycle.

Trend Analysis. Sends a pulse when a trend analysis condition is met.

Output Mode Pulse. Normal mode of operation. Pulled active when Output On condition is met and held active for the duration of the selected pulse width.

Latch Mode 1. (Unlatch Pin)

Pulled active when Output On condition is met and held active until either Input #1 or Input #2 sends a pulse to end the active state. Note: In order for this mode to work correctly, you must set either Input #1 or Input #2 to the correct polarity and set Input Function for Unlatch Output. Latch Mode 2. (Unlatch Opposite Condition) Pulled active when Output On condition is met and held active until the opposite condition of the selected Output On condition has been met. For example, if Noread is the selected Output On condition, the Programmable Output will be pulled active on a Noread condition and held active until a Good Read occurs. Latch Mode 3. (Unlatch Enter Read Cycle)

Pulled active when the Output On condition is met and held active until the Read Cycle is re-entered. Polarity. Allows you to choose a positive or negative transition for the output pulse.

Quadrus 2D Code Reader User’s Manual

3-17

3–Serial Commands

Mismatch. Sends a pulse when the label’s data does not match that of the master label.

Page 82

Chapter 3 Trend Analysis Mode A pulse will be sent when the value entered for # To Output On has been reached within the trigger window selected in Trigger Evaluation Period. Note: Image Degradation is for future use and is not functional at this time.

Output #2 Format: <Kwoutput on,polarity, pulse width,output mode trend analysis mode,trigger evaluation period, # to output on> Functions the same as Output # 1.

Output #3 Format: <KHoutput on,polarity,pulse width,output mode, trend analysis mode, trig evaluation period,# to output on>

3–Serial Commands

Functions the same as Output # 1.

Quality Output Format: <KO% cell damage,symbol contrast,total decode time,capture time,locate time,decode time,pixels per element,ECC level,contrast method,output separator> % cell damage: 0 = Disabled 1 = Enabled symbol contrast: 0 = Disabled 1 = Enabled total decode time: 0 = Disabled 1 = Enabled capture time: 0 = Disabled 1 = Enabled locate time: 0 = Disabled 1 = Enabled decode time: 0 = Disabled 1 = Enabled pixels per element: 0 = Disabled 1 = Dark elements 2 = Light elements

ECC level:* 0 = Disabled 1 = Enabled symbol contrast method: 0 = Compressed (dynamic read) 1 = Full Size (static read)

3 = Both elements output separator: any ASCII character default is SP (space)

* ECC level is found in the Symbol menu.

3-18

Quadrus 2D Code Reader User’s Manual

Page 83

Serial Verification Note: This group of commands is not available in the ESP™ menus. Format: <KScommand echo status,serial command beep status,control/hex output> command echo status: 0 = Disabled 1 = Enabled serial command beep status: 0 = Disabled 1 = Enabled control/hex output: 0 = Control 1 = Hex

Command Echo Status

Serial Command Beep Status When enabled, the reader beeps once whenever a serial command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the reader beeps five times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the five beep response.

Control Hex Output Determines response to an Echo serial command or status request command. When set to Control, ASCII control character output is enabled. for example a carriage return would be output as ^M. When set to Hex, the output is the actual character, for example, a carriage return would be output as “D”.

Quadrus 2D Code Reader User’s Manual

3-19

3–Serial Commands

When enabled, serial configuration commands is processed and the new string for that command is echoed back to the host. If an invalid command is sent to the host, the reader will echo back the current setting of that command. For example, if the current Noread Message is “NOREAD” and <Kk1, NONSENSE> is entered, the reader will echo back <Kk1, NOREAD>. In this example the attempted entry “NONSENSE” exceeds the maximum allowable seven character. Therefore it is rejected and the current NOREAD message is echoed back and remains the Noread Message. It is important to note that if a command with multiple fields is processed, some of the fields may have been processed properly following an “invalid” command. These changes will be in the string echoed back so that you will know what did or did not change.

Page 84

Chapter 3

Illumination Internal Illumination Format: <KRstatus,LED illumination time> status: 0 = Disabled 1 = Enabled

LED Illumination time: Any number between 0-65535 Default is 25641 (16.66 ms). (in 0.65 µs Increments)

External Illumination

3–Serial Commands

Format: <KYstatus,source,strobe edge,pulse width> status: 0 = Disabled 1 = Enabled source: 0 = Continuous 1 = Strobe strobe edge: 0 = Negative 1 = Positive

Illumination Settings Format: <KZshutter time,contrast,offset,AGC max.> shutter time: contrast: offset: 0 = 1/60 Any number between 0-255 Any number between 0-255 1 = 1/125 Default 200 Default 150 2 = 1/250 3 = 1/500 4 = 1/1000 5 = 1/2000 6 = 1/4000 7 = 1/10,000

AGC maximum: Any number between 0-255 Default 255

Shutter Time. Shutter Time allows you to set shutter time down to 1/10,000 of a second. Note: If you adjust Shutter Time in the ESP™ Illumination menu, you can select even shorter times, down to 1/100,000. This is possible because the ESP™ adjusts LED Illumination Time to effectively achieve exposures consistent with shutter times less than 1/ 1000. Therefore it is recommended that you use Shutter Speed either here or in ESP™ to adjust exposure.

3-20

Quadrus 2D Code Reader User’s Manual

Page 85

Image Settings Format: <Kxthreshold type,quiet zone color,number of symbols to find,fixed threshold value,flag early out> threshold type: 0 = Adaptive 1 = Fixed quiet zone color: 0 = Black 1 = White number of symbols to find: Any number from 1-6 Default is 1 fixed threshold value: Any number from 0 to 255 Default is 125 flag early out: 0 = Disabled 1 = Enabled

3–Serial Commands

Quadrus 2D Code Reader User’s Manual

3-21

Page 86 read from a scan by OCR; it may hold reading errors

Chapter 3

7 3 < o £ £ 3 Oo ic) po B ry

3-22 Quadrus 2D Code Reader User’s Manual

Page 87

Chapter

Utilities

4

Chapter Contents

Operational commands for the Quadrus™ reader can be entered as serial command strings or, in most cases, as menu selections via the Quadrus™ ESP™. This chapter includes both operational serial command strings and corresponding ESP™ commands.

Quadrus 2D Code Reader User’s Manual

4-1

4–Utilities

Read Rate............................................................................................ 4-5 Counters .............................................................................................. 4-6 Trigger.................................................................................................. 4-8 Master Label ...................................................................................... 4-10 Checksum/Part Number..................................................................... 4-13 Interface ............................................................................................. 4-14 Send................................................................................................... 4-17 Self Test............................................................................................. 4-19 Reader Status .................................................................................... 4-20 Imaging .............................................................................................. 4-21 Histogram........................................................................................... 4-22

Page 88

Chapter 4 Summary of Serial Operational Commands Table 4-1 Summary of Serial Operational Commands

Command Type

Read Rate

Counters

Trigger

4–Utilities

Master Label

Checksum

4-2

ESP™ Cmd?

Serial Command

Name

Yes

<C>

Enter Decodes/Second Read Rate Test

Yes

<Cp>

Enter Percent Read Rate Test

Yes

<J>

Exit Read Rate Test

Yes

<O>

Noread Counter Reset

Yes

<N>

Noread Counter Request

Yes

<T>

Trigger Counter Request

Yes

<U>

Trigger Counter Reset

Yes

<V>

Match Code/Good Read Counter Request

Yes

<W>

Match Code/Good Read Counter Reset

Yes

<X>

Mismatch Counter Request

Yes

<Y>

Mismatch Counter Reset

No

<t...,...>

Trigger Delay Number,Value

No

<t#?>

Request Trigger Delay Value

No

<E>

Enable Match Code

No

<F>

Disable Match Code

Yes

<)XXXX)>

Send Master Label

Yes

<)>

Request Master Label Data

Yes

<))>

Delete Master Label Data

Yes

<G>

Store Next Label Scanned as Master Label

No

<G...>

Store Next Label Scanned as Master Label #___ Send Master Label # and Data

No

<M...,...>

Yes

<!>

Display Checksum of application software

Yes

<#>

Display Software Part Number

Quadrus 2D Code Reader User’s Manual

Page 89

Table 4-1 Summary of Serial Operational Commands

Command Type

Interface (Outputs and Resets)

Download

Receive

Status

Imaging

Histogram Matrix

Serial Command

Yes

<L1>

Output # 1 Pulse

Yes

<L2>

Output # 2 Pulse

Yes

<L3>

Output # 3 Pulse

Yes

<A>

Reset

Yes

<Ad>

Restore Default Operating Parameters

No

<An>

Read Saved Operating Parameters

Name

No

<Af>

Read Saved Factory Settings

Yes

<Z>

Save for Power-on

No

<Zd>

Restore Default Operating Parameters & Save for Power-on

No

<Zp>

Save Factory Settings

Yes

<Zf>

Restore Factory Defaults & Save for Powerup

Yes

<d1>

Send Application Code

Yes

<d3>

Send Image File

No

<u1>

Receive Active Image (659 x 494 pixels)

No

<u2>

Receive Compressed Image (82 x 61 pixels)

No

<u3>

Receive Entire CCD Image (780 x 517 pixels)

No

<?>

Request Reader Error Status

No

<?1>

Request Software Status

No

<$>

Self Test & Output Results

No

<c>

Image Capture

No

<D1>

Capture and Decode Image

No

<D2>

Decode Current Image

No

<h1>

Histogram Request

No

<h2>

Histogram Statistics Request

No

<e>

Number of Pixels per Element

4–Utilities

Self Test

ESP™ Cmd?

Most of the commands listed above can be also be accessed from the Utilities menu.

Quadrus 2D Code Reader User’s Manual

4-3

Page 90

Chapter 4 For your convenience, at the bottom of each utility menu, you will see a Options button which when clicked allow you to address specific scanners on a multidrop network.

4–Utilities

Figure 4-1 Options

4-4

Quadrus 2D Code Reader User’s Manual