Page 41

Trigger Filter Default:

0

Options:

0 to 65,535 (0 to 3 seconds) (in 46 µs increments)

Allows you to set the duration of the trigger debounce time.

Trigger Variance Fixed

Options:

Fixed, Auto

Applies only if Two Triggers is selected. Choose Fixed to apply the same Trigger Delay Time to each read cycle or when setting up Two Triggers for the first time. Choose Auto for Two Triggers setup to have Quadrus™ compare subsequent edge triggers and automatically adjust Delay Time.

Trigger Level Default:

Positive

Options:

Positive, Negative

Allows you to determine whether a positive or negative transition will initiate the read cycle. Note: External Trigger (page 2-16), External Edge (page 2-16), or Serial Data & Edge (page 2-16) must be enabled for Trigger Level to take effect. Note: If using the Microscan object detector, enable Positive.

Trigger Source Default:

One Trigger

Options:

One Trigger, Two Triggers

Allows you to select one or two trigger sources. If you select Two Trigger, you can either tie both trigger inputs together into single trigger inputs (as an open collector) or wire them into separate inputs (see table A-3 on page A-3 for wiring details and notes). Note: At this time, pin 12 accepts only TTL input. When set to Two Trigger mode the Quadrus™ behaves as follows: 1. Upon receiving the first trigger edge, Quadrus™ will start a timer. 2. Upon receiving the second trigger edge, Quadrus™ will stop the timer. 1. For example, assigning an upper case C would nullify the <C> (Enter Decode Rate Test) command. For a list of operational commands used by the Quadrus™, see Chapter 4, “Operational Commands.” Quadrus 2D Code Reader User’s Manual

2-17

2–Menu Config.

Default:

Page 42

Chapter 2 3. Quadrus™ determines the ratio between the current two-trigger delta time and the previous two-trigger delta time. Note: If Trigger Variance mode is set to Auto, then Quadrus™ will decrease or increase the current Trigger Delay Time by the ratio calculated in step 3; if Trigger Variance is set to Fixed, then Trigger Delay Time will not change. You use Fixed to manually set a Trigger Delay Time for the initial setup. After that, you switch to Auto and Quadrus™ computes the speed automatically in real time.

2–Menu Config.

Trigger Delay Default:

Time

Options:

Time, Pulse

Allows you select and define the conditions (time or pulses) that must transpire before a read cycle can begin. Both these methods allow you to adjust the position of the symbol and the delay time for Quadrus™ to capture the image without moving the trigger device. However, it is significant to note that of the two, only Trigger Delay Time will function with Two Triggers enabled in Trigger Source.

Trigger Delay (µSec) 0 Default: Options:

Any number between 0 and 65,535 (0 to 3 seconds), in 46 µs Increments.

At the occurrence of an Edge Trigger the Quadrus™ will wait the designated time to capture an image.

# Pulses Default:

0

Options:

0 to 255

With Pulse enabled, the Quadrus™ will wait the designated Number of Pulses before the read cycle is activated.

Multi-Capture Mode Note: Multi-capture mode has no corresponding serial configuration command. Serial commands for multi-capture mode are found in “<t...> Multiple Trigger Delays” in Chapter 4, “.”

Default:

Disabled

Options:

Disabled, Enabled

If enabled, multiple captures can proceed from a single trigger. For each additional capture, a corresponding delay is set up using the <t...> operational command explained in “<t...> Multiple Trigger Delays” on page 4-8.

2-18

Quadrus 2D Code Reader User’s Manual

Page 43

For example, if your application requires that two symbols be read from a single trigger, you need to ensure the following: 1. Multiple Trigger Events from 1 Trigger is enabled. 2. The first trigger event is set up using the trigger delay field <KG>. 3. The second shot is set up using the <t...> operational command. 4. The # Trigger Events After 1st Trigger field is set to 1. Any number between 0 - 65,535 in 46 µs increments Default:

1

Options:

Any number from 1 to 10.

2–Menu Config.

# of Captures after Trigger

Number of captures that can occur after a trigger if Multi-Capture is enabled.

Delay Time 1 Default:

0

Options:

Any number between 0 and 65,535, in 46 µs Increments.

At the occurrence of an Edge trigger the Quadrus™ will wait the designated Trigger Delay Time before the read cycle is activated.

Read Cycle Allows you select the conditions for ending the read cycle and the timeout duration, if a timeout is selected.

End of Read Cycle Default:

Timeout

Options:

Timeout, New Trigger, Timeout & New Trigger

Timeout Can end the read cycle after a specified period of time. If no symbol has been read, a timeout causes a noread message (if enabled) to be transmitted. When External Edge, Serial Data, or Serial Data & Edge is enabled, a timeout ends the read cycle. With External Level enabled, the read cycle does not end until the falling edge (the second trigger) occurs. The next read cycle does not begin until the next rising edge trigger. With Continuous Read 1 Output enabled, a timeout initiates a new read cycle and allows the same symbol to be read again.

Quadrus 2D Code Reader User’s Manual

2-19

Page 44

Chapter 2 New Trigger Ends the read cycle at the occurrence of a new trigger event, and if no symbol has been read, causes a noread message, if enabled, to be transmitted at the occurrence of the new trigger event. With either External Edge, Serial Data, or Serial Data & Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. With External Level enabled, a falling edge trigger ends a read cycle. However, the next read cycle does not begin until the occurrence of the next rising edge trigger.

2–Menu Config.

Timeout & New Trigger Ends the read cycle after a specified period of time or at the occurrence of new trigger event, and if no symbol has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout, or an edge or serial trigger whichever comes first, ends the read cycle. An edge or serial trigger also initiates a new read cycle. With External Level enabled, the read cycle does not end until the occurrence of a falling edge, and the next read cycle does not begin until the next rising edge trigger.

Timeout (mS) Default: 1000 (one second) Options: 0 to 65,535 Allows you to set the length of time the read cycle will remain active before timing out.

Maximum Decode Time (mS) Default: 1000 (one second) Options: 0 to 65,535 Allows you to set the length of time the reader will spend, after a label has been located, attempting to decode a label before timing out and seeking another symbol. You can enable additional time if necessary to allow the Quadrus™ to use a special algorithm that will adjust decode parameters and continue to try to decode the label.

Noread Default:

Enabled

Options:

Enabled, Disabled

You can clear this box if you want to disable the noread message.

Noread Message Default:

NOREAD

Options:

Up to seven ASCII characters (except NUL)

2-20

Quadrus 2D Code Reader User’s Manual

Page 45

Allows you to define any combination of ASCII characters (except NUL) up to seven characters as the noread message. When enabled, the noread message will be transmitted to the host at a timeout or the end of a read cycle if the symbol has not been decoded.

Match Code Default:

Disabled

Options:

Disabled, Enabled, Sequential, Wild Card

Note: Enabling Continuous Read 1 will default Number of Labels (page 2-24) back to one (if set for 2) and only the first symbol in a supplemental symbol will be read. Allows you to enter a master label into the Quadrus™ memory to be compared with subsequently scanned symbols. (See “Master Label” on page 4-10.) The results of this comparison determine the reader’s data and output pulses.

Figure 2-6 Match Code Setup

The following conditions apply: • A triggered mode must be enabled for Match Code Type to take effect. • Multi-labels will not work when Match Code Type is enabled. (Enabling Match Code will cause Number of Labels to default back to one.) • If you wish to send a pulse on a Good Read, Match Code Type must be disabled.

Quadrus 2D Code Reader User’s Manual

2-21

2–Menu Config.

Note: A triggered mode (page 2-15 to page 2-16) must be enabled for Match Code to take effect.

Page 46

Chapter 2 Match Code Type Disabled. No effect on operations. Enabled. Instructs the reader to compare symbols or portions of symbols with the

2–Menu Config.

master label.

Sequential Matching. Instructs the reader to compare symbols or portions of symbols for sequential numbers in ascending or descending order. Sequencing occurs after each match. It is important to note that all sequential match code operations are performed on Master Label #1 in the Master Label Data Base. Wild Card. Allows you to enter user-defined wild card characters in the master label. For example, with wild card defined as a default asterisk, entering URGENT** as your master label will result in matches for URGENT, URGENT1, and URGENT12 but not for URGENT123. As in the above example, when wild cards are appended to the end of the master label, symbols of variable lengths can result in matches. However, wild cards in the beginning or center of a symbol (e.g., UR**NT) do not allow for variable symbol lengths.

Data Base Size Default:

10

Options:

1 to 10

You can setup from 1 to 10 the master labels. It is important to note that changing the number of master labels in the data base changes the maximum length for each master label due to a fixed data base size for the aggregate. The aggregate Master Label Data Base is 2048 bytes in size, so if The # of Master Labels is set to 1 (see <KM> command in “Multilabel” on page 2-24) then the max value for Match Start Position and Match Length is 2048. If the # of Master Labels is set to 2, the maximum data base size would be 1024, and so on until at ten symbols, the maximum per label is 204 (see “Master Label Data Base” on page 4-12). Note: Since the size of the master label data base varies according to the number of Master Labels enabled, the Match Start Position and Match Length maximum values will vary as well. Caution: You must be careful when changing the Number of Master Labels (1 to 10), because if you enter a value for Number of Master Labels that is different than the current value and any of the master labels exceed the new size limitation, all Master Labels will be deleted except Master Label #1, unless its size exceeds the new maximum.

Match Start Position Match Start Position must be set to 1 or greater to enable this feature. Defines the first character in the symbol (from left to right) that will be compared with those of the master label when Match Code Type is set to Enabled or Sequential. For example, if you set Match Start Position to 3, the first 2 characters read in the symbol will be

2-22

Quadrus 2D Code Reader User’s Manual

Page 47

ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length.

Match Length Defines the length of the character string that will be compared with that of the master label when Match Code Type is set to Enabled or Sequential and Match Start position is set to 1 or greater. For example, if Match Length is set to 6 in a 10 character symbol, and Match Start Position is set for 2, only the 2nd through 7th characters (from left to right) will be compared. Default:

Disabled

Options:

Disabled, Enabled

Enabling New Master Pin will allow you to momentarily connect the New Master Pin to ground (must be held low for a minimum of 10 ms) in order to clear any existing master label information from Master Label #1 buffer in the master label data base, and to record the next good read as the new master label information for Master Label #1. Note: This pin will not work for any of the other master labels in the data base.

Sequence on Noread When disabled, the reader does not sequence (increment or decrement) on a noread. When enabled, the reader sequences on every noread.

Sequence on every Mismatch When disabled, and if a mismatch is out of sequence by no more than 1, then the sequence resumes and searches indefinitely. When enabled, the reader sequences on every mismatch.

Master Label Edit Allows you to enter in master label data for up to 10 labels. Enter data under Master Label 1, scroll down to Master Label 2 and enter data for that label, and so on.

Reader Output When to Output (symbology data) Default:

As Soon As Possible

Options:

As Soon As Possible, End of Read Cycle

Allows you to choose when the symbol’s data is sent to the host computer.

Quadrus 2D Code Reader User’s Manual

2-23

2–Menu Config.

New Master Pin

Page 48

Chapter 2 As Soon As Possible Causes symbol data (good reads) to be transmitted immediately upon a good decode.

End of Read Cycle Causes symbol data output to be delayed until the end of the read cycle.

2–Menu Config.

Bar Code Output Default:

Good Read

Options:

Good Read, Disabled, Match, Mismatch

Note: If Bar Code Output is set to Match or Mismatch, symbol data will not output unless Match Code is enabled and a master label is received into memory.

Beeper Status Default:

On Good

Options:

On Good, On Noread, Disabled

A beep is emitted either after each good read or noread.

Multilabel Allows you to define the number of different symbols that the reader will read during a single trigger event (including multiple symbols decoded within a frame).

Separator Default:

, (comma)

Options:

Any ASCII character except NUL, <, or >.

Allows you to define the ASCII character that will separate symbol data when it is sent to the host.

Number of Labels Default:

1

Options:

1 to 6

Note: If Number of Labels is set to 2 while Match Code or Continuous Read 1 is enabled, Number of Labels will default back to one. Allows you to choose the number of different symbols that will be read in a single trigger event. The labels can be a mix of any enabled bar code symbologies and more than one label can be decoded per frame.

2-24

Quadrus 2D Code Reader User’s Manual

Page 49

Symbol Menu The Symbol menu allows you to setup specific parameters of each symbology. (See figure 2-7.)

2–Menu Config.

Figure 2-7 Symbol Setup

Default Clicking the DEFAULT button will reset all options on the Symbol menu to factory defaults. You can then click Apply followed (in the pop-up dialog box) by SEND/NO SAVE or SEND/SAVE.

Quadrus 2D Code Reader User’s Manual

2-25

Page 50

Chapter 2 Background Color Default:

White

Options:

White, Black

Background color is important. Use the finder pattern as your reference. If the finder pattern is white (or light), the background color should be black (or dark). The terms Black and White are relative and you should think in terms of lighter or darker.

2–Menu Config.

Symbol Type Default:

ECC 200

Options:

ECC 000, ECC 050, ECC 080, ECC 100, ECC 140, ECC 200

See “Data Matrix Symbology” on page A-13 for descriptions.

Identifiers You can instruct the reader to output the ECC Level (symbol type) and/or the symbology identifier along with the label data.

ECC Level (symbol type) Default:

Disabled

Options:

Disabled, Enabled

Allows you to enable the reader to output the symbol type (ECC 200, ECC 000, etc.).

Symbology Identifiers Default:

Disabled

Options:

Disabled, Enabled

If Symbology Identifier is enabled, it adds a prefix to the decoded data. The symbology identifier for Data Matrix is: ]dm where: ] is the symbology identifier flag (ASCII value 93). d is the code character for the Data Matrix symbology. m is a modifier character with one of the values defined in table 2-1.

2-26