Table 2-1 Symbology Identifier Option Values for Data Matrix
Option Value
Option ECC 000-140
1
ECC 200
2
ECC 200, FNC1 in 1st or 5th position
3
ECC 200, FNC1 in 2nd or 6th position
4
ECC 200 supporting ECI protocol
5
ECC 200, FNC1 in 1st or 5th position plus supporting ECI protocol
6
ECC 200, FNC1 in 2nd or 6th position plus supporting ECI protocol
Quadrus 2D Code Reader User’s Manual
2–Menu Config.
0
2-27
Page 52
Chapter 2
In/Out Menu
2–Menu Config.
The Reader In/Out menu allows you to set the conditions under which Quadrus™’s inputs and outputs symbol data, signals, and pulses.
Figure 2-8 Reader In/Out Setup
Symbology output data and noread messages are transmitted on pin 2 under conditions set principally in Bar Code Output. Pulses are transmitted via pins 6 and 8 (Output 1 and Output 2 respectively) and individually configured under conditions set in Output 1 and Output 2.
Default Clicking the DEFAULT button will reset all options on the In/Out menu to factory defaults. You can then click Apply followed (in the pop-up dialog box) by SEND/NO SAVE or SEND/SAVE. Allows you to choose the conditions that will send symbol data (or noread messages) to the host computer via RS-232 on pin 5.
2-28
Quadrus 2D Code Reader User’s Manual
Page 53
Input Configuration Input 1 applies to host pin 12, Input 2 applies to host pin 21.
Default Click the DEFAULT button to display factory default settings for Input 1.
Default:
Positive
Options:
Positive, Negative
2–Menu Config.
Polarity Figure 2-9 Input 1 Dialog Box
Allows you to choose a positive or negative transition.
Input Mode Default:
Disabled
Options:
Disabled, Reset Counts, Unlatch Output, Set Trigger Delay
Disabled No input signals.
Reset Counts Resets all counters.
Unlatch Output Sends a pulse to end active state of Latch Mode 1 set in Output 1, Output 2 or Output 3.
Trigger Delay When Trigger Delay is enabled, both the 1st and 2nd trigger input pulses will be expected at the Trigger Input (pin 10). When Set Trigger Delay is not enabled, trigger input from the 1st trigger will be expected at Input-1 (pin 12). Caution: Input-1 accepts TTL level voltage only.
Output Configuration Output 1 applies to host pin 6. Output 2 applies to host pin 8. Output 3 applies to host pin 15.
Quadrus 2D Code Reader User’s Manual
2-29
Page 54
Chapter 2
2–Menu Config.
Upon selecting this option a dialog box will appear:
Figure 2-10 Output 1
Default Click DEFAULT button to display factory default settings.
Output On Default:
Mismatch or Noread
Options:
Mismatch or Noread, Match, Mismatch, Noread, Trend Analysis
Allows you to set the conditions that will output a pulse. To see the options for enabling Match Code and receiving a master label into memory see “Master Label” on page 4-10. Note: If Output On is set to Mismatch or Noread, or Mismatch, a relay pulse will not output unless Match Code is enabled and a master label is received by reader memory.
Mismatch or Noread Sends a pulse (to the output pin that is enabled) when the symbol's data does not match that of the master label or the label is not decoded before the end of the read cycle. Note: Matchcode must be enabled for a pulse to be sent. (See “Operations Menu” on page 2-14.)
2-30
Quadrus 2D Code Reader User’s Manual
Page 55
Match Sends a pulse (to the output pin that is enabled) when the decoded symbol matches the master label. (If Match Code is disabled, a good read will have the same effect.) Note: Matchcode must be enabled for a pulse to be sent. (See “Operations Menu” on page 2-14.)
Mismatch
Note: Matchcode must be enabled for a pulse to be sent. (See “Operations Menu” on page 2-14.)
Noread Sends a pulse (to the output pin that is enabled) when the symbol’s data is not decoded before the end of the read cycle.
Trend Analysis Outputs a pulse when a trend analysis condition is met. (See“Trend Analysis” on page 2-32.)
Output Mode Default:
Pulse
Options:
Pulse, Latch Mode 1, Latch Mode 2, Latch Mode 3
Allows you to select either pulse or latch output mode.
Pulse Enabling Pulse allows a pulse to be sent when the selected Output On condition is met. Enabling Latch causes the output to toggle high or low (depending on selected polarity) when the selected Output On condition is met.
Latch Mode 1 (unlatch pin) The programmable output is pulled active when the Output On condition has been met and is held active until either Input #1 or Input #2 is toggled to the opposite polarity. Note: In order for this mode to work correctly, you must set either Input #1 or Input #2 to the correct polarity and set Input Function for Unlatch Output.
Latch Mode 2 (unlatch opposite condition) The programmable output is pulled active when the Output On condition has been met and is held active until the opposite of the Output On condition is met. For example, if Noread is the condition set in Output On, Output will be pulled active upon a Noread condition and held active until a Good Read condition occurs.
Quadrus 2D Code Reader User’s Manual
2-31
2–Menu Config.
Sends a pulse (to the output pin that is enabled) when the decoded symbol does not match the master label.
Page 56
Chapter 2 Latch Mode 3 (unlatch Enter Read Cycle) The programmable output is pulled active when the Output On condition has been met and is held active until the Read Cycle is re-entered.
Pulse Width (in 10 ms incs) Default:
5 (.05 seconds)
2–Menu Config.
Options: 0 to 255 (divide the number entered by 100 for time in seconds) Allows you to set the duration of the good match/noread output signals at the output pin that is enabled. When the edit box is selected, you can use the arrow keys to increase or decrease the settings, or you can just enter the value.
Polarity Default:
Negative
Options:
Negative, Positive
Allows you to choose a positive or negative transition.
Trend Analysis Trend Analysis Mode Outputs a pulse when a trend analysis condition is met. Default:
Noread
Options:
Image Degradation, Mismatch, Noread
Allows you to select the type of analysis that the reader will monitor. Note: Image Degradation is for future use and is not functional at this time.
Trigger Evaluation Sample Default:
10
Options:
0 to 255
Allows you to set the number of triggers.
Number to Output On Default:
5
Options:
0 to 255
Allows you to set the number of times a condition that you define in Trend Analysis Mode occurs in the Trigger Evaluation Sample to cause an output.
2-32
Quadrus 2D Code Reader User’s Manual
Page 57
Quality Output When you check Quality Output parameters, Quadrus™ calculates each and appends these values to each label output. For example, if you enable all the outputs, they will be returned in the order shown in table 2-2. See “Sample Symbol # 1, Thermal” on page 5-9 for a functional description and examples with different labels. Table 2-2 Full Quality Outputs % Cell Damage
Symbol Contrast
Total Decode Time
Capture Time
Locate Time
Decode Time
Pixels per Element
Both Elements enabled
0123456789abcdefghijklmnopqrstuvwxyz 0 128 256 36 210 10 13 17 light pixels dark pixels
You can choose to output symbol quality values by checking any of the following check boxes:
% Cell Damage. Number of cells (also called elements) damaged per total number of cells x 100. The ideal reading is 0 (zero).
Symbol Contrast. The difference between the arithmetic means of the darkest 10% and lightest 10% of the image pixels which fall within the area of the symbol, extending outward to the limits of any required quiet zones. A value of 80 is considered optimum, with 70 as a minimum for an A-grade threshold.
Total Decode Time. Displays the sum of Capture Time, Locate Time, and Decode Time. A target total is anything under 200 ms that guarantees you are getting at least 5 scans per second (1000 ms/200 ms).
Capture Time. Displays the time elapsed between the CCD trigger and all the CCD data has been DMA’d to external memory. Note: Capture time is dependent on the shutter time.
Locate Time. For the first label in the field of view, the time from the start of image processing until the label has been located and is ready to be decoded. For each additional label in the field of view, the time from the exit of the decode function of the previous label until the current label has been located and is ready to be decoded.
Decode Time. Time required to decode label.
Quadrus 2D Code Reader User’s Manual
2-33
2–Menu Config.
Label data
Page 58
Chapter 2 Pixels Per Element. Default:
Disabled
Options:
Disabled, Dark Elements, Light Elements, Both Elements
You can output pixels per dark element, pixels per light element, or both. This calculation records the number of pixels for each element, either dark or light, in the clocking pattern for both x and y directions.
2–Menu Config.
Enabling Both Elements is very useful since you can quickly compare the balance between dark and light pixels.
Contrast Method. Default:
Compressed
Options:
Compressed, Full Size
Method used to calculate the symbol contrast of the image, either compressed or fullsized.
Output Separator. Allows you to select an ASCII character as a separator between the label data and the appended Quality information.
Recommended Quality Output Setup 1. In the In/Out menu, check % Cell Damage, Symbol Contrast, and Total Decode Time. 2. Set Pixels per Element to Both Elements, as shown in figure 2-11.
Figure 2-11 Quality Output Options
3. In the Trigger menu under Utilities, click the Serial Trigger Character SETUP Button and click Send.
2-34
Quadrus 2D Code Reader User’s Manual
Page 59
Output Filter Default:
Disabled
Options:
Disabled, Enabled
If only part of the information in a label is to be transmitted to the host, Output Filter can be used. It allows a preset number of characters to be transmitted starting at a set position in the label. In the multilabel mode, partial output is performed on each separate label. “1234567890” is transmitted as “34567” “1234” is transmitted as “34”
“1234,abcde” is transmitted as “34,ab”
“12” is transmitted as “”
Start Default is 1. Range is 1 to 300
Length Default is 63. Range is 1 to 300
Quadrus 2D Code Reader User’s Manual
2-35
2–Menu Config.
For example, if the start position is set to 3 and the length to 5, the following occurs:
Page 60
Chapter 2
Illumination Menu
2–Menu Config.
Upon selecting this menu a dialog box will appear which will contain the following:
Figure 2-12 Illumination Menu
Note: See “Illumination Adjustment Flow” on page 5-8.
Default Clicking the DEFAULT button will reset all options on the Illumination menu to factory defaults. You can then click Apply followed (in the pop-up dialog box) by SEND/NO SAVE or SEND/SAVE.
Illumination You can enable or disable the Internal Illumination. You can also adjust the duration of time the LEDs will be on. However, the Quadrus™ ESP™ will do this automatically when you set shutter time in ESP™ Illumination menu. Therefore you should make your exposure time adjustments in Shutter Time before attempting to change LED Illumination Time. However, if you do need to fine-tune your exposure time, you can make adjustments in LED Illumination Time (by serial command only), but should observe the following:
2-36
Quadrus 2D Code Reader User’s Manual