The text of a manual · part 4 of 17
Quadrus 2D Code Reader User's Manual, pages 31 to 40
Pages 31 to 40 of 166
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan 6500
Page 31
Full Duplex Mode In full duplex mode, all aux port data and bar code data is sent directly to the host. Bar code data is not transmitted to the aux port device.
Data initiated from the Aux Port. •Aux port data is passed directly through to the host whenever it is received by the reader, unless the reader is in a polled mode, in which case the data will be ignored.
Aux. Port
Host
Quadrus™
• Aux Port data to the host will not have a preamble or a postamble.
Data initiated from the Reader . •Scan data is not sent to the aux port. Aux. Port
Host
Quadrus™
Data initiated from the Host.. •In unpolled mode, all host data is echoed to the aux port. Aux. Port
Host
Quadrus™
Daisy Chain Mode In a daisy chain application, a primary reader is linked directly to the host and succeeding readers are linked in tandem. Data from succeeding readers is transmitted directly to the host as if it were coming from the primary reader.
Succeeding Reader(s)
Host
The conditions for a daisy chain application are: 1. The primary reader’s trigger and the succeeding readers’ Primary Reader triggers must be set to External or Serial. If all are set to Serial, the host can send serial triggers to all readers in the chain. 2. Each succeeding reader in the daisy chain must have its host connections connected to the aux. port of its preceding reader and enabled for serial or external trigger.
Quadrus 2D Code Reader User’s Manual
2-7
2–Menu Config.
• Aux Port data is not echoed.
Page 32
Chapter 2 3. Each succeeding reader in the daisy chain should be set to send its data no less than 20 ms before its preceding reader. For example, if the primary reader is set to timeout in 100 ms, the first succeeding reader can be set to 80 ms, the next to 60 ms, etc. 4. Postamble must be set to CR (^M) and enabled. 5. Succeeding readers must have noread messages disabled. 6. Multilabel separator characters and the number of labels must match in all readers in the daisy chain.
2–Menu Config.
Daisy Chain Status. Default: Disabled Options:
Disabled, enabled
Daisy Chain ID. Default: 1 and / Options:
One or two ASCII characters
Daisy Chain Description. Just before sending a noread message, the primary reader checks its auxiliary port for data. It waits a maximum of 20 ms. If no character is received in 20 ms, it sends a noread message to the host. After each character received, it waits up to 20 ms for the next character or a CR. If a complete message is received, it is sent to the host instead of the noread message. Daisy-chained readers can send a series of symbols by enabling Multilabel and a common multilabel separator. If a reader does not receive the expected number of labels, noread messages are appended to the data string to make up the difference between the number of labels enabled in Multilabel (Number of Labels) and the number of labels read. For example, a primary and two succeeding readers have Number of Labels set to 3 and Multilabel Separator defined as %. If the primary and the first succeeding reader do not find labels, but the next reader registers a good read, the transmitted results would be: label data % noread % noread.
Command Process If enabled, allows you to enter ESP™ or direct serial string commands via the Quadrus™ aux port. It is important to note that while Quadrus™ can determine which port - host or aux - to output data in response to serial commands, it has no way of knowing which port to output externally triggered read cycle data. Therefore when Command Process mode is selected, Quadrus™ will output externally triggered read cycle data in one of two ways: 1. If the last command came from the aux port, then externally triggered read cycle data will be output to both the host and the aux ports. 2. If the last command came from the host port, then externally triggered read cycle data will only be output to the host port.
2-8
Quadrus 2D Code Reader User’s Manual
Page 33
Protocol Menu Selected Protocol Default:
Point-to-Point
Options:
Point-to-Point, Point-to-Point with XON/XOFF
Figure 2-3 Protocol
Default Clicking the DEFAULT button will reset all options on the Protocol menu to factory defaults. You can then click Apply followed (in the pop-up dialog box) by SEND/NO SAVE or SEND/SAVE.
Quadrus 2D Code Reader User’s Manual
2-9
2–Menu Config.
Protocols define the sequence and format in which information is transferred between devices.
Page 34
Chapter 2 Selected Protocol Default:
Point-to-Point
Options:
Point-to-Point, Point-to-Point with RTS/CTS, Point-to-Point with XON/XOFF, Point-to-Point with RTS/CTS & XON/XOFF, Polling Mode D, Multidrop, User Defined, User Defined Multidrop
2–Menu Config.
Protocols define the sequence and format in which information is transferred between devices.
Point-to-Point Has no address and sends data to the host (RS-232) whenever it is available and without any request or handshake from the host.
Point-to-Point with RTS/CTS (Request-to-Send/Clear-to-Send) Used only with RS-232. This is a simple handshaking protocol that allows a device to initiate data transfers to the host with an RTS (request-to-send) transmission. The host, when ready, responds with a CTS (clear-to-send) and the data is transmitted. CTS and RTS signals are transmitted over two dedicated wires (see table A-1 on page A-3).
Point-to-Point with XON/XOFF (Transmitter On/Off) Used only with RS-232. This selection enables the host to send a single byte transmission command of start (XON) or stop (XOFF). If an XOFF has been received from the host, data will not be sent to the host until the host sends an XON. During the XOFF phase, the host is free to carry on other chores and accept data from other devices.
Point-to-Point with RTS/CTS & XON/XOFF Used only with RS-232. It is a combination of Point-to-Point with RTS/CTS and Pointto-Point with XON/XOFF.
Polling Mode D Like Point-to-Point, Polling Mode D requires a separate connection to the host; but unlike Point-to-Point, it requires an address and must wait for a poll from the host before sending data. When in Polling Mode D, an address of 1 is automatically displayed on the configuration screen. However, during transmission, a 1C hex poll address (FS) and a 1D hex select address (GS) are substituted for the 1.
Multidrop Note: Readers intended to link up to a Microscan MS-5000 multidrop concentrator must be configured in standard Multidrop protocol. Note: To avoid slow or degraded performance when the Quadrus™ is networked with Microscan’s MS-5000 multidrop concentrator, the MS-5000 must have Turnaround Timeout set to 35 ms and should have Baud Rate set to 38.4 and Number of Devices
2-10
Quadrus 2D Code Reader User’s Manual
Page 35
set to no more than the actual number of connected devices. See MS-5000 Multidrop concentrator User’s Manual. Similar to Polling Mode D except that a unique poll address and select address are required for each multidrop device, and only one host port connection is needed for up to 50 devices. (For Multidrop poll and select characters, see Table A-8, “Multidrop Address Characters,” on page A-19.)
User Defined Note: A specific ASCII character must not be assigned more than once. Used only with RS-232. User Defined is necessary when a new protocol must be defined to match a specific host protocol. ASCII characters can be assigned as an address and as protocol commands (RES, REQ, EOT, STX, ETX, ACK, NAK, From Host). In order to enable a handshaking protocol, you must manually assign values where necessary. When User Defined is selected, the displayed protocol commands match those of the previously selected protocol. User Defined is considered to be in a polled mode only if an address has been assigned. The address can be any ASCII character from the ASCII table in Appendix F on page A-12. If null is selected as the address, the reader will not function in a polling sequence. From Host, if enabled, allows the handshaking protocol to be initiated from the host, if unpolled. Default:
Disabled
Options:
Disabled, Enabled
Messages sent to the host from the Quadrus™ will always include the reader’s defined protocol. The status of From Host determines if messages sent to the Quadrus™ from the host must also include the defined protocol. If From Host is disabled, the defined protocol is not included. If From Host is enabled, the defined protocol must be included. (See “Selected Protocol” on page 3-7 for further information.)
User Defined Multidrop Used when connecting to a concentrator or other device that does not match standard Multidrop protocol. Any single character (even-numbered, 02 hex to 7E hex) in the ASCII table can be assigned as the address character. The character chosen is used as the poll character and the subsequent ASCII character becomes the select character. For example, if a ^B (02 hex) is selected as the address, ^C (03 hex) becomes the select address that the host will use in sending host select commands. (See Table A-7, “ASCII Table with Control Characters,” on page A-12.)
Quadrus 2D Code Reader User’s Manual
2-11
2–Menu Config.
Requires a concentrator or controller using RS-485 communications. When Multidrop is selected, the protocol characters for RES, REQ, etc. are assigned automatically. (See “Appendix I, Multidrop Communications” on page A-17 for poll and select sequences.)
Page 36
Chapter 2 Note: Definitions of commands in User Defined and User Defined Multidrop must be duplicated in host applications to enable poll and select sequences to execute correctly during transmission. Note: Typically, parameters in User Defined Multidrop are defined by first enabling Multidrop, then enabling User Defined Multidrop. This pre-loads Multidrop characters into the parameters. You then change individual characters to match the host or other requirements.
2–Menu Config.
Output Data Format Preamble (enable/disable) Default:
Disabled
Options:
Disabled, Enabled (within any protocol)
Allows you to enable or disable the preamble character(s).
Preamble (definition) Default:
CR (carriage return).
Options:
Up to four ASCII characters except NUL, <, or >.1
If enabled, allows you to define up to four characters that can be added in front of the symbol data. For example, a carriage return.
Postamble (enable/disable) Default:
Enabled
Options:
Enabled, Disabled (within any protocol)
Allows you to enable or disable the Postamble character(s).
Postamble (definition) Default:
CR LF (carriage return/line feed).
Options:
Up to four ASCII characters except NUL, <, or >.1
Allows you to define up to four characters that can be added after the symbol data. When enabled, the default CR LF causes each symbol to be displayed on its own line.
Response Timeout (character) Default: 4 (40 ms) Options:
0 to 255 (in 10 ms increments)
Allows you to set the time the reader will wait between characters before timing out if ACK, NAK, and ETX are enabled, and a host response is expected.
1. In the case where only one character is entered, a NUL character is selected to serve as a place holder; however, no output will result.
2-12
Quadrus 2D Code Reader User’s Manual
Page 37
Intercharacter Delay Default:
0
Options:
0 to 255 in 10 ms increments. Zero (0) causes no delay between characters.
Allows you to set the time interval in milliseconds between individual characters transmitted from the Quadrus™ to the host computer. A high setting will significantly slow down communications. For example, a 200 setting will result in a 2 second delay between each character that is transmitted.
Default:
Disabled
Options:
Disabled, Enabled
An error-checking routine that verifies the accuracy of transmissions. It is the exclusive OR of all characters in the transmitted message. The result is appended to the end of the transmitted message.
Quadrus 2D Code Reader User’s Manual
2-13
2–Menu Config.
Longitudinal Redundancy Check (LRC)
Page 38
Chapter 2
Operations Menu
2–Menu Config.
The Operations menu allows you to set the operations parameters for the Quadrus™. (See figure 2-4.)
Figure 2-4 Operations Menu
Default Clicking the DEFAULT button will reset all options on the Operations menu to factory defaults. You can then click Apply followed (in the pop-up dialog box) by SEND/NO SAVE or SEND/SAVE. Note: Selecting the Default button will only restore those settings of the current menu.
Trigger Click Trigger Setup button to set Trigger Mode, Trigger Level, Trigger Variance, Trigger Source, and Trigger Delay.
2-14
Quadrus 2D Code Reader User’s Manual
Page 39
Trigger Mode Default:
External Edge
Options:
External Edge, Continuous Read, Continuous Read 1, External Level, External Edge, Serial Data, Serial Data & Edge
Allows you to establish the type of trigger event that will initiate and end the read cycle. (See “End of Read Cycle” on page 2-19.)
2–Menu Config.
Figure 2-5 Triggering Setup
Continuous Read Note: Continuous Read is typically used for testing only. Trigger input options are disabled and the Quadrus™ is always in the read cycle. Symbol data is decoded, and symbol information is transmitted repeatedly, as long as the symbol is in the read range of the Quadrus™. When To Output options have no affect on Continuous Read. Continuous Read is useful in testing read performance. Note: If Match Code is enabled, the Quadrus™ defaults to Continuous Read 1.
Continuous Read 1 When enabled, symbol data is immediately transmitted once every time new symbol data is placed in front of the Quadrus™. With End Of Read Cycle set to Timeout and the symbol not changed, the Quadrus™ repeats the output at the end of each timeout period. For example, if Timeout is set to one second, the Quadrus™ outputs the symbol data immediately, and then repeats the output at intervals of one second, for as long as the symbol continues to be scanned. With End Of Read Cycle set to New Trigger, the Quadrus™ outputs the current symbol data immediately, but outputs it only once. A new symbol appearing at any time in the scan range will produce a new read output as long as the new symbol is not identical to the previous symbol. Quadrus 2D Code Reader User’s Manual
2-15
Page 40
Chapter 2 Note: Enabling Continuous Read 1 will default Number of Labels (page 2-24) back to one (if set for 2) and only the first symbol in a supplemental label will be read.
External Level
2–Menu Config.
Allows a read cycle to be initiated by a trigger signal from an object detector when an object appears within the detector’s range. The read cycle endures until the object moves out of the detector’s range unless a good read or timeout occurs (if Timeout is enabled for End of Read Cycle).
External Edge As with Level, Edge allows a read cycle to be initiated by a trigger signal, but unlike level mode, the read cycle ends with a good read output, a timeout, or a new trigger. If Edge Single Shot is enabled then the read cycle will also end on a noread regardless of the timeout setting.
Serial Data Quadrus™ accepts an ASCII character from the host or controlling device as a trigger to start a read cycle.
Serial Data & External Edge The Quadrus™ accepts either an external trigger or a serial ASCII command to start and end a read cycle.
Single Shot Default:
Enabled
Options:
Enabled, Disabled
When enabled, an edge or serial trigger will begin the read cycle which ends after one captured image, without reference to good decodes or timeout. It is useful in trend analysis and can check daisy chain output in a noread condition. It also treats data from auxiliary port as if it were decoded from the current frame of data.
Serial Trigger Character Default:
GS (^] corresponds to <GS> displayed in menu)
Options:
Any single ASCII character except NUL, an existing host command character, or an on-line protocol character.
Note: Serial Data (page 2-16) or Serial Data & Edge (page 2-16) must be enabled for Serial Trigger Character to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Allows you to define a single ASCII character as the host serial trigger character that initiates the read cycle.1 The serial trigger is considered an on-line host command and requires the same command format as all host serial commands (that is, to be entered within the < > brackets).
2-16
Quadrus 2D Code Reader User’s Manual