Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 17

Quadrus 2D Code Reader User's Manual, pages 21 to 30

Pages 21 to 30 of 166

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Microscan 6500

Page 21

Static Label Setup 1–Quick Start

Step 8 Static Label Setup a) Click THE ILLUMINATE tab to analyze and change illumination settings.

Illuminate

Figure 1-8 Illumination b) Click the Send button. If a decodable label is in your field of view, you will see a compressed image of the symbol, as shown in figure 1-8. c) To see a histogram of the object represented by the polygon, place your cursor tip over the polygon and double click. The goal here is to make the necessary adjustments to the illumination parameters to enable decoding and improve read quality. You can do this by analyzing quality output, histograms, and line scans. See “Illuminate” on page 5-3 for detailed instructions on setting up and fine-tuning your reader.

Quadrus 2D Code Reader User’s Manual

1-9

Page 22

1–Quick Start

Chapter 1

Step 9 Moving Label Setup When you click Dynamic, you see the Dynamic parameters (figure 1-9) which allow you to set up for multiple symbols and adjust the time delay between the appearance of a moving object (as sensed by an external object detector) and the arrival of its associated symbol or symbols in the center of the reader’s view.

Dynamic

Figure 1-9 Dynamic Setup

You can also go back to static setup and adjust shutter time, etc. in the Illumination dialog box and retest in “Dynamic.” For complete info on setting up Quadrus™ for a dynamic (moving labels) application, see “Dynamic Setup” on page 5-13.

1-10

Quadrus 2D Code Reader User’s Manual

Page 23

Saving Settings 1–Quick Start

Step 10 Saving Settings Using the Send/Recv dialog box, you can send your current settings to the reader’s memory by clicking SEND/NO SAVE. You can also save your current settings to the reader for power-up by clicking SEND/SAVE. Once you’ve arrived at satisfactory settings for a particular symbol or operation, you may want to save these settings to a file on your host computer by using the File\Save As function and creating a file name that relates to your symbol or application. This allows you to continue on and make additional changes to your scanner without losing the originals. See also “Interface” on page 4-14 for other save/ reset/recall operations.

Figure 1-10 Send/Receive Dialog

Note: Allow at least 3 seconds after saving before sending a command or starting another operation.

Quadrus 2D Code Reader User’s Manual

1-11

Page 24

1–Quick Start

Chapter 1

1-12

Quadrus 2D Code Reader User’s Manual

Page 25

Chapter

2

Menu Configuration 2–Menu Config.

Chapter Contents Using ESP™ to Configure the Quadrus™ ........................................... 2-2 Communications Menu ........................................................................ 2-3 Protocol Menu...................................................................................... 2-9 Operations Menu ............................................................................... 2-14 Symbol Menu ..................................................................................... 2-25 In/Out Menu ....................................................................................... 2-28 Illumination Menu ............................................................................... 2-36 Custom Menu..................................................................................... 2-39

This chapter tells how to configure the Quadrus™ using the ESP™ program on a Windows based (Windows 3.1 or Windows 95) computer. Note: Related serial commands that can be entered by commands from a host or an auxiliary computer are listed in Chapter 3, “Serial Commands.” After changes are made in the configuration menus, they can be sent in total to the Quadrus™ and the current settings will be posted in a status window. It is important to note that configuration settings can be saved directly to the Quadrus™ or as files to your computer that can individually be recalled at a later date and saved to the Quadrus™. Note: See Step 3, “Install ESP™ on Host Computer,” on page 1-4 and Chapter 4, “Utilities,” for testing and operational uses of the ESP™ program.

Quadrus 2D Code Reader User’s Manual

2-1

Page 26

Chapter 2

Using ESP™ to Configure the Quadrus™ Figure 2-1, “Configuration Setup File,” shows the window you will see when you launch the Quadrus™ ESP™.

2–Menu Config.

Pull down menus Toolbar An “Untitled...” file loads with the original factory default settings Access configuration menu changes here. Terminal emulation window displays echoed commands and data Click here to calibrate your label setup File status: Also titled “Current Menu/Reader Settings” following a save or receive You can also access the configuration menus by selecting any item here. Allows you to perform tests and access operational information. Allows you to send/receive between the Quadrus™ and the host

Click here to evaluate images

Figure 2-1 Configuration Setup File

To access the configuration menus, press the MENU button. If using a mouse, single click on menu items and enter text as appropriate. If using the keyboard, use the Alt key, underlined letters, and the tab key to move to the desired field. You can then use arrow keys or the space bar to scroll through the selections and the Enter key to accept changes.

2-2

Quadrus 2D Code Reader User’s Manual

Page 27

Communications Menu The Communications menu allows you to set the communication protocols of the Quadrus™. (See figure 2-2.).

2–Menu Config.

Figure 2-2 Communications Menu Structure

When you make and save menu communications changes to the Quadrus™, those changes will automatically be matched in the Serial Port configuration.

Default Clicking the DEFAULT button will reset all options on the Communications menu to factory defaults. You can then click Apply followed (in the pop-up dialog box) by SEND/NO SAVE or SEND/SAVE.

Host Port Parity Default:

None

Options:

None, Even, Odd

Allows you to select an error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. Quadrus 2D Code Reader User’s Manual

2-3

Page 28

Chapter 2 Data Bits Default:

Eight

Options:

Seven, Eight

Allows you to establish the total number of bits in each character.

2–Menu Config.

Stop Bits Default:

One

Options:

One, Two

Allows you to select the last one or two bits in each character to indicate the end of the character.

Baud Rate Default:

38.4K

Options:

1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K

Allows you to set the number of bits transmitted per second.

Aux Port Parity Same as Host Port

Data Bits Same as Host Port

Stop Bits Same as Host Port

Baud Rate Default:

38.4K

Options:

1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K

Allows you to set the number of bits transmitted per second.

Aux Port Mode Default:

Disabled

Options:

Disabled, Transparent, Half Duplex, Full Duplex, Daisy Chain, Cmd Process

Allows you to set communications parameters between the reader and an auxiliary port. An auxiliary port can be used to configure the menus, send data to the host, and display data transmissions originating from the host or reader. The Aux Port baud rate should never exceed Host Port baud rate or auxiliary port data could be lost.

2-4

Quadrus 2D Code Reader User’s Manual

Page 29

Transparent Used to batch data from the aux port to the host. The reader buffers data from the aux port and displays the keyed data on the aux port. The reader transmits aux port data to the host when a symbol is scanned or a carriage return is entered from the aux port.

Data Initiated from the Aux Port. •Aux Port data is passed

• Aux Port data to the host is always sent with a preamble and a postamble.

Aux. Port

Host

• If the reader is in a polled mode to the host, aux port data will still pass through.

Quadrus™

Data initiated from the Reader. •Transmission to the aux port occurs immediately upon a good read. • Scan data to the aux port does not include a preamble or a postamble. • Communications with the aux port is always in Point-toPoint protocol, even if the host is in a polled protocol mode.

Aux. Port

Host

Quadrus™

Data initiated from the Host. •In unpolled mode, all host data is echoed to the aux port. Aux. Port

Host

Quadrus™

Quadrus 2D Code Reader User’s Manual

2-5

2–Menu Config.

through to the host whenever a return key is pressed at the aux port or whenever bar code data is sent. If sent with bar code data, it is processed on a first-in/first-out basis

Page 30

Chapter 2 Half Duplex Mode In half duplex mode all aux port data and bar code data is sent directly to the host. Bar code data is transmitted to the aux port device at the same time the data is sent to the host.

Data initiated from the Aux Port. •Aux Port data to the host is ignored if the reader is in a polled mode.

2–Menu Config.

• Aux Port data or scanned data is sent to the host whenever it is received. • Aux Port data is not echoed.

Aux. Port

Host

• Aux Port data to the host is always sent without a preamble or a postamble. Quadrus™

Data initiated from the Reader. •Scan data is transmitted to the aux port at the same time it is transmitted to the host. Data transmission conforms with all parameters specified in the configuration menu (e.g., Preamble, Postamble, End of Read Cycle).

Aux. Port

Host

Quadrus™

Data is initiated from the Host. •In unpolled mode, all host data is echoed to the aux port. Aux. Port

Host

Quadrus™

2-6

Quadrus 2D Code Reader User’s Manual