Page 11

Certification Labels This certification label is located on the back of the Quadrus™ • Designed for FCC, TüV, CE, CDRH, UL/cUL • ISO 9001/Cert. No. US96/0465.

1201 SW 7th St. Renton,W A 98055 THIS EQUIPM ENT HAS BEEN TESTED W ITH CLASS A COM PUTING DEVICES AND HAS BEEN FOUND TO COM PLY W ITH PART 15 OF FCC RULES,SEE INSTRUCTION M ANUAL.OPERATION IN A RESIDENTIAL AREA M AY CAUSE UNACCEPTABLE INTERFERENCE TO RADIO AND TV RECEPTION REQUIRING THE OPERATOR TO TAKE W HATEVER STEPS ARE NECESSARY TO CORRECT THE INTERFERENCE.

COVERED BY ONE OR M ORE OF THE FOLLOW ING PATENTS AND PATENTS PENDING. 5,291,009 5,354,977 5,532,467

J2

LISTED UL 1950 4K68

PO W ER

DECODE 10-28V 5W

11--120030

J3

J4

Back of Quadrus™ xi

Page 12

xii

Page 13

Quick Start

1

Chapter Contents Step 1 - Attach Cabling ........................................................................ 1-2 Step 2 - Mount Quadrus™ ................................................................... 1-3 Step 3 - Install ESP™ on Host Computer ............................................ 1-4 Step 4 - Open ESP™ ........................................................................... 1-5 Step 5 - Establish Communications ..................................................... 1-6 Step 6 - Locate Symbol........................................................................ 1-7 Step 7 - Center Symbol in the Field of View ........................................ 1-8 Step 8 - Static Label Setup .................................................................. 1-9 Step 9 - Moving Label Setup.............................................................. 1-10 Step 10 - Saving Settings .................................................................. 1-11

This chapter will get you started quickly with your setup and give you references for further information.

Quadrus 2D Code Reader User’s Manual

1-1

1–Quick Start

Chapter

Page 14

1–Quick Start

Chapter 1

Step 1 Attach Cabling a) Attach host cable to the Quadrus 25-pin host connector. Note: See Appendix A, “Quadrus™ Specifications” for pinout and connector types. Caution: Do not use a host cable with more wires connected than required for the application. The host connector of the reader has many outputs that could cause damage or interfere with normal operation if connected and improperly used. b) Attach power cable to power connector. If using Microscan power supply, use PN 97-100004-07 (120V) or PN 97-100004-08 (240V). c) If used, attach trigger device to trigger connector. (Microscan offers object detector, PN 99-440001-08 and PN 99-440002-01).

25-pin host connector

Power connector

Trigger connector

Figure 1-1 Quadrus™ Connectors on Back of Quadrus™

1-2

Quadrus 2D Code Reader User’s Manual

Page 15

Mount Quadrus™ 1–Quick Start

Step 2 Mount Quadrus™ Position Quadrus™ at the correct distance from your symbol.

5" (12.7 cm) 4" (10.16 cm) 2" (5.08 cm)

UHD

High Density

Low Density

Figure 1-2 Distance from Symbols

If using an ultra high density (UHD) model, the reader should be placed 2 inches (5.08 cm) from the symbol. If using the high density, the reader should be 4 inches (10.16 cm) from the symbol. If using the low density, the reader should be 5 inches (12.7 cm) from the symbol. For best results, pitch or skew reader 10° to 20° relative to symbol. Note: See “Quadrus™ Specifications” on page A-2 for Quadrus™ mounting dimensions.

Quadrus 2D Code Reader User’s Manual

1-3

Page 16

1–Quick Start

Chapter 1

Step 3 Install ESP™ on Host Computer Note: ESP™ (Easy Setup Program) runs on Microsoft Windows 3.1 and Windows 95™ operating systems. It is assumed that you are familiar with your operating system and the procedures for installing Windows-based programs. To install ESP™: a) Make a backup copy of the ESP™ disk(s). b) Double-click the setup icon and follow the on-screen directions:

c) Select a directory and/or a sub-directory for your ESP™ as requested:

d) Upon completion, you will have a shortcut icon that looks like this:

1-4

Quadrus 2D Code Reader User’s Manual

Page 17

Open ESP™ 1–Quick Start

Step 4 Open ESP™ a) Double-click the ESP™ icon.

b) You will see a screen similar to figure 1-3

Pull-down menus Toolbar

Settings window

Figure 1-3 Main ESP™ Menu

Quadrus 2D Code Reader User’s Manual

1-5

Page 18

1–Quick Start

Chapter 1

Step 5 Establish Communications a) To set up your host communications, first select your Serial Port from the pull down Serial Port Configuration menu (figure 1-4). Note: Laptops are typically set to Com 1; desktops are typically set to Com 2. b) From the toolbar, click on the Auto Baud button, which looks like this: Quadrus will cycle through the various baud, parity, data bit, and stop bit combinations until it finds the one that allows it to connect with your computer. Once connected, you will see a green button at the bottom of your screen like this: Figure 1-4 Host Serial Port Configuration

You can also select Serial Port (figure 1-4) and make setting directly.1 c) To transfer your current ESP settings to the reader, click SEND/RECV button on the main menu and click SEND/NO SAVE or SEND/SAVE to save for power up. d) If you want to load the settings from the reader to the host computer, click RECEIVE FROM READER. You will see the horizontal bar at the bottom of the box fill up with blue (figure 1-5).2 If you fail to establish communications, a communication parameter may be set incorrectly, you have a mismatched ESP/application programs, or you may have a loose or bad host Figure 1-5 Reader Configuration Transfer cable connection.

1. The defaults are 38.4K Baud Rate, None for Parity, 8 Data Bits, and 1 Stop Bits. 2. The blue bar is a timer and does not necessarily indicate a successful transfer of settings from the reader to the host.

1-6

Quadrus 2D Code Reader User’s Manual

Page 19

Locate Symbol 1–Quick Start

Step 6 Locate Symbol a) With a label in front of the Quadrus at the proper distance, click the CALIBRATION button. b) Click the LOCATOR tab. Unless you enabled Single Shot for Serial Trigger (in the Operations menu), Calibration will put the Quadrus™ in a Continuous mode (overriding any other trigger settings), and cause it to search for images and symbols. When Quadrus™ finds an object that satisfies its criteria for a symbol, Quadrus™ displays it in the locator box as a polygon outline. The outline will be red if Quadrus™ detects an extraneous object or fails to decode a symbol. It will be green if a symbol is successfully decoded.

Read rate bar

Locator

Figure 1-6 Calibration/Locate

Quadrus 2D Code Reader User’s Manual

1-7

Page 20

1–Quick Start

Chapter 1

Step 7 Center Symbol in the Field of View When an object is detected in the field of view (FOV), it is represented by a red or green outline in the Locate Label dialog box window. If the outline is Red, the object could be a symbol that has not yet been decoded. If green, the object is a symbol that has successfully been decoded. a) While watching the response of the outline(s) inside the Locate Label dialog box window, reposition the label or Quadrus™ (without changing the recommended distance between them) until you’ve centered the label in the window. b) You will minimize specular reflection and improve your read rate if you are careful to set the Quadrus™ at least 15° angle relative to a line perpendicular with the label. c) To confirm that Quadrus™ is looking at your symbol, check Overlay option to see a compressed image. Note: In Overlay mode, there is approximately 1 second delay between image captures. Note: The read rate percentage, from 0 to 100, is indicated by the read rate bar below the message window (figure 1-6).

At20.2least 15° °

Note: For in depth discussion of illumination parameters, see "Illuminate” on page 5-3.

Label Figure 1-7 Label/Quadrus™ Position

1-8

Quadrus 2D Code Reader User’s Manual