Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 17

Quadrus 2D Code Reader User's Manual, pages 141 to 150

Pages 141 to 150 of 166

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Microscan 6500

Page 141

Maximum Symbol Sizes UHD Symbol Sizes U H D D ensity F ield of V iew = 0 .6 5" x 0 .47 "

Field of View X

Y

0.65"

0.47"

Diagonal (inc h es)

Diagonal (inches) plu s 25%

Appendices

Figure A-6 Quadrus™ UHD Symbol Size Limitations

Table A-6 Maximum Symbol Size by Element (UHD, Ultra High Density) Element 5 mil Square Symbols Rectangular Symbols

Row x Col. in elements

20 mil

25 mil

52 x 52 26 x 26 24 x 24 18 x 18 16 x 16 12 x 12

8 mil

10 mil

13 mil

15 mil

10 x10

Diagonal symbol size .460" .368" .424" .414" .424" .424" .442" plus 25% 1.14 cm 0.93 cm 1.08 cm 1.05 cm 1.08 cm 1.08 cm 1.12 cm Row x Col. in elements

16 x 48 36 x 48 12 x 26

8 x 12

8 x 12

8 x 12

Diagonal symbol size .316" .394" .358" .234" .270" .361" plus 25% .803 cm 1.00 cm .909 cm .594 cm .686 cm 917 cm

Quadrus 2D Reader User’s Manual

A-9

Page 142

Appendix E, Optional Equipment Universal Stand The Microscan Universal Stand is available in 4-inch, 6-inch, and 10-inch flex models. • 4-inch, knob adjustable handle98-200008 • 6-inch, knob adjustable head and foot98-200007

Appendices

• 10-inch flax neck, adjustable head98-200006 • 7-1/4-inch extension kit 98-200024

4 inch Universal Stand Mates to adaptor plate Ball joint

6 inch Universal Stand

10 inch Flex Neck Universal Stand

Adjust knob 4" 10.16 cm

.25" .635 cm

6" 15.24 cm

10 " 25.40 cm

.25 " .635 cm 2" 5.080 cm

.190" DIA. .483 cm DIA. 4 PL

6-inch Extension Bar Kit

2.5" 6.350 cm

Bottom

3-inch Extension Joint Kit 6" 15.24 cm 3" 7.62 cm

1.250" 3.175 cm

. 50" D IA. 1 270c m DIA. 3P l . .20" DIA. .508 cm DIA. 3 PL 1.250" 3.175 cm

1.125" 1.125" 2.858 cm C 2.858 cm L

Figure A-7 Universal Stand

A-10

Quadrus 2D Reader User’s Manual

Page 143

Optional Equipment Adaptor Plate C L

4X .190 THRU 92 .350

2X R1.143

.250

2X R.652

4X 8-32UNC-2B THRU

3.265

3.137 3.829

Appendices

2.686 2.532

1.032 .300 .350 .261

R.03 .850 1.049

Microscan PN 98-200018

C L 1.700

Figure A-8 Adaptor Plate -- Quadrus™ to Universal Stand

Base Plate B as e P la te B ase P la te H o le P atte rn

(R edu ce d scale) 7" (17.8 cm )

1.0" 2.54 cm

3.5" (8.9 cm )

9" 22.9 cm

2.0" 5.08 cm

CL

1.125" 2.86 cm

2.025" 5.14 cm

1.59" 4.04 cm

6.97" 17.7 cm .75" 1.90 cm

.344" .874 cm

.725" 1.84 cm

Microscan PN 98-200017-01

C L Figure A-9 Base Plate

Quadrus 2D Reader User’s Manual

A-11

Page 144

Appendix F, ASCII Table

Appendices

Table A-7 ASCII Table with Control Characters

A-12

Dec

Hex

Mne

Ctrl

Dec

Hex

Ch

Dec

Hex

Ch

Dec

Hex

Ch

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

^@ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_

32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

SP ! " # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

96

60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ D

Quadrus 2D Reader User’s Manual

97 98

99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

Page 145

Data Matrix Symbology

Appendix G, Data Matrix Symbology1 Individual element (or module) A white corner on a white background symbol indicates an even number of elements per side, a black corner indicates an odd number.

Appendices

Even number of elements per side indicates an ECC 200; an odd number indicates 000 to 140 (in most cases) Alternating finder pattern on two sides used to define cell structure Solid finder pattern on two sides define physical size, orientation and symbol distortion

Figure A-10 Data Matrix ECC 200 Symbol

Symbol Features

ECC 000 - 140

ECC 200

Number of rows and columns (including finder pattern)

Odd (except for some closed applications)

Even

Element in upper right hand corner

Dark (for light background labels)

Light (for light background labels)

Error correction routine

Convolution

Reed-Solomon

Symbol sizes (not including quiet zones)

17 to 21 sizes (squares only)

24 squares 6 rectangular

Append in structured format

No

Yes, up to 16 symbols

Subdivide code word stream into blocks for error detection

No

Yes, for symbols with more than 255 code words

Extended channel interpretation for other character sets

No

Yes, optional

Data encoded in:

Base 11, 27, 41, 37, ASCII, 8-bit Byte

ASCII, C40, text, X12, EDIFACT, and Base 256

1. For complete specification, see International Symbology Specification-Data Matrix, by AIM International; http:\\www.aimi.org

Quadrus 2D Reader User’s Manual

A-13

Page 146

Pixels and Elements

Pixels

Appendices

Element

Symbol Figure A-11 Pixel/Element Relationship

Figure A-11 shows the relationship between pixels and an ECC 200 symbol. Each reader density model (UHD, High Density, and Low Density) has a minimum pixel to element ratio For successful decoding, which depends on illumination, orientation, and quality of printing.

Symbol Sizes Since symbols are positioned an exact distance from the front of the Quadrus™, it is possible to calculate the limits to the size of symbols for each density model. Tables A-4, A-5, and A-6 show precise sizes per element size for EEC 200 symbols. These are calculated for the worse case scenario; each symbol is rotated diagonal to the shorter Y (height) dimension of the reader’s field of view and 25 percent additional space is added on to this to allow for quiet zones.

A-14

Quadrus 2D Reader User’s Manual

Page 147

Histograms

Appendix H, Histograms To generate a histogram, place the tip of your cursor on the red or green border line of the object, and double click. The resulting histogram can be seen in figure A-12.

Histogram

Figure A-12 Histogram 1

The vertical dashed red line is the threshold that separates pixels interpreted as black from those designated as white, those to the left being black and those to the right being white. Good Image contrast usually has a bimodal histogram with its low and high peaks as far apart as possible.

To see statistical information of the histogram click the Statistics button (figure A-13).

Quadrus 2D Reader User’s Manual

A-15

Appendices

A histogram is a graphical presentation of the numeric count of the occurrence of each intensity (grey level) in an image. The horizontal axis is the values of grey levels and the vertical axis is the number of pixels for each grey level.

Page 148

4. To move the peaks further apart, increase the contrast. For example, changing Contrast to 190 produces a wider histogram as seen in figure A-14.

Appendices

Since Auto Threshold Adjust is enabled, Threshold has changed from 100 to 126. This keeps the red line centered between the peaks.

Figure A-13 Statistics for Histogram 1

As shown in figure A-14, the histogram peaks have moved apart. 5. Now, if you reduce the offset and further increase the Contrast, you will get an even better histogram. 6. Test by clicking the Image and Statistics buttons.

Figure A-14 Histogram 2

A-16

Quadrus 2D Reader User’s Manual

Page 149

Multidrop Communications

Appendix I, Multidrop Communications This appendix describes the rules for setting up a concentrator or controller to communicate with a Quadrus™ in standard Multidrop protocol, as presented in “Protocol Menu,” on page 2-9.

Multidrop Addresses • No two readers in the Multidrop Network can have the same address.

Host

Concentrator or Controller

• Each reader in the network must have an address (from 01 to 50) assigned in its configuration program.

Polled Protocol Multidrop ONLY RS-485 Interface (LAN)

Reader 01

Each address has its own separate poll and select address (from 1C to 7F hex as shown in table A-8 on page A-19). For example, during a polling sequence, Reader 03 expects a 20 hex (“SP” ASCII poll character) from the concentrator. And during a select command, it looks for a select value 21 hex (“!” ASCII select character).

Appendices

Figure A-15 shows a typical Multidrop network in which 1 to 50 readers can communicate with a host via an intermediary device, a concentrator or a controller.

Reader 02 Reader 03 Figure A-15 Typical Multidrop Network

Polling Sequence Data that is transmitted to the host (bar code data, noread messages, counters, etc.) via concentrators is solicited by poll requests from the host. End of Sequence

Start of Sequence

Concentrator Scanner 02

RES 1E REQ

ACK 1E STX DATA ETX LRC

RES

Figure A-16 Polling Sequence

The polling sequence example in figure A-16 begins with a RES (reset) from the concentrator followed by poll address 1E (ASCII hex value for Reader 02) and a REQ (request). The reader responds by first transmitting its own address, 1E, followed by a STX (start of text) character, and then the data. Next it transmits an ETX (end of Quadrus 2D Reader User’s Manual

A-17

Page 150

text) character and an LRC (longitudinal redundancy check) character. If the concentrator (or controller) receives the data from the reader and is able to validate it with an LRC calculation, it responds with an ACK (acknowledgment). If the reader in turn sends the ACK, the reader ends this successful exchange with a RES (reset).

Polling Reset

Appendices

• If the reader has no information, it responds to a poll request by transmitting a RES (reset). • If the reader receives a NAK instead of the ACK after transmitting its data string, it will transmit the data string again up to three times. If the reader still does not receive an ACK, it will transmit a RES (reset) and discard the data in its buffers. • If the READER transmits data to the concentrator and the concentrator responds with an ACK or NAK, but the reader doesn’t receive the concentrator’s response, the reader will timeout and transmit a REQ to the concentrator and request another response. If after three retries (the number of times it transmits a REQ to the concentrator) the reader receives no response, it ends the transmission with a RES (reset).

Select Sequence Unlike poll requests, select commands always originate from the host and consist of serial configuration or operation commands to devices that are configured in Multidrop. The reader complies with the command when it is polled during the cycle. Figure A-17 is an example of a select sequence. Start of Sequence

Concentrator RES 1F REQ Scanner 02

End of Sequence

STX <T>ETX LRC 1F ACK

RES 1F ACK

Figure A-17 Select Sequence

A RES (reset) is the first command in the select sequence. The 1F hex is the select address associated with Reader 02 address (see table A-8 on page A-19). It is followed by a REQ (request). The reader responds with its own select address, 1F hex, and an ACK (acknowledge). The concentrator then transmits an STX (start of text), the data (in this case a <T>), an ETX (end of text), and an LRC character. The reader replies by transmitting its own address, followed by an ACK, acknowledging receipt of the command. Upon receipt of an ACK, the concentrator concludes the successful exchange with a RES. In the example above, the reader only acknowledges a trigger counter request from the concentrator. It does not respond to the trigger counter request until a subsequent poll. For example, if the reader’s trigger count was 12 at the time the trigger

A-18

Quadrus 2D Reader User’s Manual