The text of a manual · part 16 of 17

Quadrus 2D Code Reader User's Manual, pages 151 to 160

Pages 151 to 160 of 166

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Microscan 6500

Page 151

Multidrop Communications counter request was received, on a subsequent poll it would transmit 02T/00012. (The 02 at the beginning of the string is the reader’s address.)

Select Reset • If the reader receives bad data from the concentrator, it transmits a SEL (its select address) and a NAK to the concentrator. The concentrator transmits the data up to three times. The concentrator will end the sequence with a RES (reset) if no ACK is received.1 Table A-8 Multidrop Address Characters

Poll Character

Select Character

Multidrop Address

Poll Character

Select Character

ASCII

HEX

ASCII

HEX

ASCII

HEX

ASCII

01

^\

1C

^]

1D

26

N

4E

O

HEX 4F

02

^^

1E

^-

1F

27

P

50

Q

51

03

SP

20

!

21

28

R

52

S

53

04

"

22

#

23

29

T

54

U

55

05

$

24

%

25

30

V

56

W

57

06

&

26

'

27

31

X

58

Y

59

07

(

28

)

29

32

Z

5A

[

5B

08

*

2A

+

2B

33

\

5C

]

5D

09

,

2C

-

2D

34

^

5E

_

5F

10

.

2E

/

2F

35

`

60 a

61

11

0

30

1

31

36 b

62 c

63

12

2

32

3

33

37 d

64 e

65

13

4

34

5

35

38 f

66 g

67

14

6

36

7

37

39 h

68 i

69

15

8

38

9

39

40 j

6A k

6B

16

:

3A

;

3B

41 l

6C m

6D

17

<

3C

=

3D

42 n

6E o

6F

18

>

3E

?

3F

43 p

70 q

71

19

@

40

A

41

44 r

72 s

73

20

B

42

C

43

45 t

74 u

75

21

D

44

E

45

46 v

76 w

77

22

F

46

G

47

47 x

78 y

79

23

H

48

I

49

48 z

7A

{

7B

24

J

4A

K

4B

49

|

7C

}

7D

25

L

4C

M

4D

50

~

7E

∆

7F

1. For additional information on Multidrop, see the MS-5000 Multidrop Concentrator User's Manual.

Quadrus 2D Reader User’s Manual

A-19

Appendices

Multidrop Address

Page 152

Appendix J, Glossary of Terms Adaptive. Routine in Quadrus™ code that sets threshold from data acquired from the current read only. (See Fixed.)

Appendices

Bandwidth. Range of frequencies (energy transitions) that are allowed to pass through bandpass filters during signal processing. Baud Rate. The term used to describe the number of discrete signal events per second. In RS-232 and RS-422/485 systems, baud rate is the same as bits per second (bps). Bimodal. Relating to a histogram. Two peaks showing definite separation between light and dark values. Bin. An individual stack of pixels at a given grey scale value on a histogram. Capture. A single frame, shot, or picture. The total CCD image acquired by the Quadrus™ and held in its buffer for analysis and decoding. CCD Array. The grid of CCDs (literally, “charged-coupled devices”) in a linear or 2D reader that senses light. Configuration. The method used to change factory default settings for operational features to match a specific application. Configuration can be done through the ESP™ menus or with serial commands. Connector. Physical device (plug or socket) on unit or cable to provide in/ out connectivity for various circuits and pins. Convolution. Error correction scheme used by ECC 000 - 140. Counter. Memory space provided to keep track of read cycle events. CRC. Cyclical Redundancy Check. A 32 bit string of the length value and binary data file received. Data Matrix. Two-dimensional code type characterized by arrays of square elements and a finder pattern. Decode Rate. The number of good reads per second decoded by the reader. Default. The original factory settings. Defaulting. Act of resetting the reader to the original factory settings. Dynamic Setup. Testing and configuration done with symbols in motion. ECC 000 to 140. Two-dimensional Data Matrix symbols characterized by an odd number of elements, except for some closed applications. ECC 200. Two-dimensional Data Matrix symbol characterized by an even number of elements. Edge. External Triggering mode in which a detected object is recognized by a single edge pulse.

A-20

Quadrus 2D Reader User’s Manual

Page 153

Glossary of Terms Element. Smallest square-shaped component of a 2D symbol in light or dark contrasting shades. End of Read Cycle. The time at which the reader stops expecting label information to decode. This can be caused by a timeout, a trigger event, or a good read. EPROM. Erasable, programmable, read only memory. Error Correction. Scheme to check accuracy of data. Fixed. The dividing line between dark and light pixels is represented in Quadrus™ histograms as a vertical dashed line Exposure Time. The duration of time the Quadrus™ CCD array is available to capture an image. See Illumination Time. Frame. A single capture, shot, or picture. The total CCD image received by the Quadrus™ and held in its buffer for analysis and decoding. Focal Length. The distance measured from the reader to the center of the depth of field, or focal point. FOV. Field of View. The rectangular pattern in which a label can be read by the CCD array. Good Match. The event occurring when a scanned label matches the master label information that is stored in the memory of the reader. Good Read. The event that occurs when a label's data is accurately scanned and decoded. Histogram. A visual representation of the frequency of various intensities of light (grey levels) in an image. Illumination. The light, external or internal, flashed over a symbol sufficient to enable the reader to detect each element within a given symbol. Illumination Time. The duration in which the LED’s are held on during image capture. See Exposure Time. Label Speed. The rate in inches or centimeters per second at which a label moves through the scan beam. LED Illumination. Internal Quadrus™ light source. Level. The period of time between the arrival and departure of an object is referred to as “level,” a reference to the horizontal signal that is displayed on an oscilloscope. Line Scan. Graphical representation of the grey scale levels of a selected slice of the image. Master Label. A label or label data that is stored in the reader’s memory and is compared with subsequently scanned labels. Match Code. The ability to compare data matrix labels being scanned against a master label that is stored in the memory of the reader. Quadrus 2D Reader User’s Manual

A-21

Appendices

Flash Memory. Non-volatile random access memory.

Page 154

Matrix Symbology. Grid of rectangular elements (or modules) in a regular pattern to represent data for retrieval by a vision scanning system. Menu Configuration. The process of changing factory default settings via a sequence of menus displayed on a terminal monitor. Mil. One thousandths of an inch or 0.0254 mm. In bar-coding, a measurement that identifies a data matrix label by the width of its narrowest element. Mismatch. An event that occurs when the scanned data matrix label does not match the master label that is stored in the memory of the reader.

Appendices

Module. Another name for Element. See Element. Noread. A non-read. A condition that occurs when the reader is set up to decode labels, and no labels are scanned during the read cycle. Null. A non-printed character that acts as a space-holder. Number of Scans Calculation. The number of times a data matrix label is scanned by the reader during one pass. Object Detector. A photo electric device used to sense the presence or absence of an object. One Shot. Single frame or capture. Operational Commands. Serial commands from the host to the reader that control current operating parameters, counters, master label operations, and program management that are not stored in non-volatile RAM. Parity. An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. Pitch. Label (or reader) rotation around the center of a line parallel to the label’s line of travel. Point-to-Point. A protocol consisting of a single communications event, typically used to connect a data matrix reader to a terminal or host computer. Port. Logical circuit for data entry and exit. (One or more ports may be included within a single connector.) Protocol. The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Quiet Zones. Specified “clear” (nonprinted) areas between data matrix symbols and other image objects. The quiet zone is greater than one element in width, and should have the opposite reflectance value of the finder pattern. Read Cycle. A programmed period of time or condition during which the reader will accept data matrix label input. Read Range. The distances in which a label can be reliably read, as measured from the front of the reader. See “Depth of Field.” Reed-Solomon Error Correction Code. A linear, error correcting block code used

A-22

Quadrus 2D Reader User’s Manual

Page 155

Glossary of Terms by ECC 200, suited to the correction of character errors which could be, in bar or matrix codes, the obliteration or removal of part of the symbol. ROM. Read Only Memory. Memory that cannot be changed. Reader. A scanning device that is comprised of a scan head and a decoder integrated in one package. Serial Commands. Online data strings (including configuration and operations) from a host or other terminal to the reader, that are always preceded by a < left angle bracket symbol and followed by a > right angle bracket symbol.

Single Shot. Single frame or capture. Skew. Label (or reader) rotation around the center of the skew axis, a line perpendicular to the label’s direction of travel and the center of the reader’s beam. Specular Reflection. The direct, mirror-like reflection of light back to the reader, causing saturation. Static Setup. Menu driven interface to allow testing and adjustment of stationary symbols. Strobe Pulse. An reader output pulse synchronized to allow external strobe illumination. Strobe Rate. Number of strobes per second that the reader projects. Symbology. A set of Data Matrix symbols, such as Data Matrix, that have special rules to define the elements and patterns to represent specific numeric or alphanumeric information. Tilt. Label (or reader) rotation around the centerline of the FOV. For 2D code, this is 360°. Timeout. A user-selected period of time that ends a reader's read cycle.

Quadrus 2D Reader User’s Manual

A-23

Appendices

Serial Configuration (Host Configuration). Serial command specifically for changing configuration and distinguished from operational command by the fact that they modify the non-volatile for power up configuration. Most of these commands begin with the upper case K character immediately following the left angle bracket symbol, as in <Kg3>.

Page 156

Appendices A-24

Quadrus 2D Reader User’s Manual

Page 157

Index Symbols # of Captures after Trigger 2-19, 3-10 # Pulses 2-18 % Cell Damage 2-33 % cell damage 3-18

A About the Quadrus vii About This Manual vii Action 6-7 Adaptive 2-38 Adaptor Plate A-13 AGC maximum 3-20 Analysis 6-6 Application Code 4-17 Approvals viii As Soon As Possible 2-24 ASCII Table A-14 Aux Port 2-4, 3-6

Background Color 2-26 Background Offset 2-38, 5-7 Bar Code Output 2-24 Base Plate A-13 Baud Rate (aux port) 2-4 Baud Rate (host port) 2-4 Beeper 3-14 Beeper Status 2-24 Binary Code 4-20 Boot Code 4-18

Index

B

CDRH viii, ix CE Compliance viii CE Konformitätszeichen ix Cell Damage 2-33 Certification Labels xi Checksum 4-13 Command Echo Status 3-19 Command Process (aux port) 2-8 Communication Protocols A-2 Communications 1-6 Communications Menu 2-3 Communications Port 3-6 Compliance Certifications A-2 Concatenating Serial Commands 3-4 Concentrator A-19 Configuration Serial Commands, summary 3-2 Connectors 1-2 Continuous 2-37 Continuous Read 2-15 Continuous Read 1 2-15 Contrast 2-38, 5-6 Contrast Method 2-34 Control Hex Output 3-19 Controller A-19 Coordinate Data 4-21 Counters 4-6 CRC 4-18 Creating a New Configuration File A-6 cUL viii, ix Custom Menu 2-39

D

C Cabling 1-2 Cabling (ground loops) A-5, A-22 Calibrate Symbol 1-7 CALIBRATION 5-2 Capture 6-4 Capture Image and Decode 4-21 Capture Time 2-33 capture time 3-18 Caution Summary viii

Daisy Chain Mode (aux port) 2-7 Data (aux port) 2-4 Data Base Size 2-22 Data Bits (host port) 2-4 Data Matrix 3-15 Decode 6-5 Decode Current Image 4-21 Decode Data 4-21 Decode Status 4-21 Decode Time 2-33

Quadrus 2D Code Reader User’s Manual

I-1

Page 158

Index

Index decode time 3-18 Decodes/Second 4-5 Defaulting A-7 Delay Time 1 2-19 Delete Master Label Data 4-11, 4-12 Disable Match Code 4-11 Distance from Symbol 1-3 Download 4-17 Dynamic Setup 1-10, 5-13

H

E

Identifiers 2-26 ILLUMINATE 1-9 Illuminate 5-3 Illumination 2-36, 3-20 Illumination Menu 2-36 Illumination Settings 2-38, 3-20 Image Capture 4-22 Image File 4-18 Image Flow 6-4 Image Settings 3-21 Image Source 6-3 Imaging 4-21 In/Out 3-16 In/Out Menu 2-28 Input # 1 3-16 Input #2 3-16 Input Mode 2-29 Intercharacter Delay 2-13, 3-9 Interface 4-14 Internal 2-37 Internal Illumination 3-20

ECC 200 Symbology A-15 ECC Level 2-26 ECC level 3-18 Edge 2-16 Edge Single Shot 3-10 Electrical A-2 Electrical Specifications A-3 Elements A-16 End of Read Cycle 2-19, 2-24 ESP 1-4, 1-5, 2-2 EVALUATION 6-2 External 2-37 External Edge 2-16 External Illumination 3-20 External Level 2-16 External Source 2-37

F Factory Defaults 4-16 Factory Settings 4-16 FCC viii, ix Field of View 1-8 Fixed 2-38 fixed threshold value 3-21 flag early out 3-21 Full Duplex Mode (aux port) 2-7

G Glossary A-23 Good Match 3-17 Ground and Shield Considerations A-22 Grounding A-5

I-2

Half Duplex Mode (aux port) 2-6 high density 1-3 High Density Symbol Sizes A-9 Histogram 4-22, 5-3, A-17 Host Port 2-3, 3-6 Host Serial Port Configuration 1-6

I

K Keystroke Entries vii

L laser beam x Laser Etch 5-10 Latch Mode 3-17 Latch Mode 1 2-31 Latch Mode 2 2-31, 3-17 Latch Mode 3 2-32, 3-17 Length Indicator 4-17

Quadrus 2D Code Reader User’s Manua l

Page 159

Length of Decoded Data 4-21 Level 2-16 Light Collection A-2 Light Source A-2 Line Scan 6-6 Load 6-5 Locate Label 5-2 Locate Symbol 1-7 Locate Time 2-33 locate time 3-18 LOCATOR 5-2 Longitudinal Redundancy Check 2-13, 3-9 low density 1-3 Low Density Symbol Sizes A-8 LRC 3-9

Multilabel 3-12 Multilabel Separator 2-24 Multiple Trigger Delays 4-8

M

O

Master Label 4-10 Master Label Data Base 4-12 Master Label Edit 2-23 Match 2-31 Match Code 2-21, 3-13, 4-10 Match Code Type (master label) 2-22 Match Code/Good Read Counter 4-7 Match Length 2-23 Match Start Position 2-22 Matrix 4-22 Maximum Decode Time 2-20 Maximum Symbol Sizes A-8 Mechanical Specifications A-2 Mirror 5-2 Mismatch 2-31, 3-17 Mismatch Counter 4-7 Mismatch or Noread 2-30, 3-17 Mode (aux port) 2-4 Mount Quadrus 1-3 Moving Label 1-10 Multi-Capture 3-10 Multi-Capture Mode 2-18 Multidrop 2-10, 3-7 Multidrop Communications A-19

Object detector 1-2 Offset 2-38, 5-7 offset 3-20 Operational Serial Commands, summary 4-2 Operations 3-10 Operations Menu 2-14 Optional Equipment A-12 Output # 1 3-16 Output # 1 Pulse 4-16 Output # 2 Pulse 4-16 Output # 3 Pulse 4-16 Output #2 3-18 Output #3 3-18 Output Data Format 2-12 Output Filter 2-35, 3-16 Output Mode 2-31, 3-17 Output On 2-30, 3-17 Output Separator 2-34 output separator 3-18 Outputs 2-29, 4-16 Overlay 1-8, 5-2

N Narrow Margins 3-15 New Master Pin 2-23, 3-13 New Trigger 2-20 Noread 2-20, 2-31, 3-17 Noread Counter 4-6 Noread Message 2-20, 3-12 Number of Labels 2-24 Number of Objects 4-21 number of symbols 3-21 Number to Output On 2-32

Parity (aux port) 2-4

Quadrus 2D Code Reader User’s Manual

I-3

Index

P

Page 160

Index

Index Parity (host port) 2-3 Part Number 4-13 Percent Read Rate Test 4-5 Pixels A-16 Pixels Per Element 2-34 pixels per element 3-18 Point-to-Point 2-10, 3-7 Point-to-Point with RTS/CTS 2-10 Point-to-Point with RTS/CTS & XON/XOFF 2-10, 3-7 Point-to-Point with XON/XOFF 2-10, 3-7 Polarity (input) 2-29 Polarity (output) 2-32 Polarity, output 3-17 Polling Mode D 2-10, 3-7 Polling Sequences A-19 Postamble 2-12, 3-9 Power Connector A-3 Power connector 1-2 Preamble 2-12, 3-8 Protocol 2-10, 3-7 Protocol Commands 3-8 Protocol Menu 2-9 Pull-down menus 1-5 Pulse 2-31, 3-17 Pulse Width 2-32

Q Quality Output 2-34, 3-18, 5-10 quiet zone color 3-21

R Read Cycle 2-19, 3-12 Read Rate 4-5 Read Saved Factory Settings 4-15 Read Saved Operating Parameters 4-15 Reader Output 2-23, 3-14 Reader Status 4-20 RECEIVE FROM READER 1-6 Receiving Settings A-6 Request Master Label Data 4-12 Request Master Label Information 4-11

I-4

Reset 4-14 Reset Functions 4-14 Reset/Save (Save for power on) 4-15 Response Timeout 2-12, 3-9 Restore Default Operating Parameters 4-15 Restore Default Operating Parameters/Save for Power-on 4-16 Restore Factory Defaults & Save for Power-on 4-16 RS-422 3-6

S Safety A-2 Save Factory Settings 4-16 Saving Settings 1-11, A-6 Saving Settings to the Quadrus A-6 Select Sequence A-20 Self Test 4-19 Send Master Label Information 4-11, 4-12 SEND/NO SAVE 1-6, 1-11 SEND/RECV 1-6 SEND/SAVE 1-6, 1-11 Separator 2-24 Sequence on every Mismatch 2-23 Sequence on Noread 2-23 Sequential 2-22 Serial Command Beep Status 3-19 Serial Commands, Configuration 3-2 Serial Commands, Operational 4-2 Serial Configuration 3-4 Serial Data 2-16 Serial Data & Edge 2-16 Serial Port 1-6 Serial Trigger Character 2-16 Serial Verification 3-19 Shielding A-5 Shutter Speed 5-14 Shutter Time 2-38, 3-20, 5-6 Sicherheitshinweis ix Single Shot 1-7, 2-16 Software Reset 4-14 Specifications A-2

Quadrus 2D Code Reader User’s Manua l