Page 21
SCANNER OPERATION Sweet Spot Mode The sweet spot mode is used to determine where the maximum read rate area or “sweet spot” is located for a specific bar code type. When activated this mode provides visual and audible feedback indicating how the scanner is scanning. Number of Illuminated LEDs 4
Beeper Pitch high
% of Maximum Read Rate 81 - 100%
3
61 - 80%
2
41 - 60%
1
21 - 40%
0 low
0 - 20%
For further information on the sweet spot mode and instructions on how to enable it, refer the MetroSelect Configuration Guide (00-02407).
17
Page 22
SCANNER OPERATION Audible Indicators When the IS3480 is in operation, it can provide audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). For instruction on how to change the tone of the beeper, refer to the MetroSelect Configuration Guide (00-02407). One Beep When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep once (the white LED will remain on for the duration of the beep). The scanner is now ready to scan. When the scanner successfully reads a bar code, the white LED will flash and the scanner beeps once (if configured to do so). If the scanner does not beep once and the white light does not flash, then the bar code has not been successfully read. Razzberry Tone This is a failure indicator. Refer to Failure Mode Indicators on page 20. Three Beeps - during operation When placing the scanner in configuration mode, the white LED will flash while the scanner simultaneously beeps three times. The white and blue LEDs will continue to flash until the unit exits configuration mode. Upon exiting configuration mode, the scanner will beep three times and the white LED will stop flashing. When configured, three beeps can also indicate a communications timeout during normal scanning mode. When using one-code-programming, the scanner will beep three times: the current selected tone, followed by a short pause, a high tone and a low tone. This tells the user that the single configuration bar code has successfully configured the scanner. Three Beeps - on power up This is a failure indicator. Refer to Failure Mode Indicators on page 20.
18 www.metrologic.com
Page 23
SCANNER OPERATION Visual Indicators There are four LEDs located on the top of the IS3480. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner. No LEDs The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. They are also not illuminated when all lasers are turned off for any reason. Steady Blue When the laser is active, the blue LED is illuminated. The blue LED will remain illuminated until the laser is deactivated. Steady Blue and Single White Flash When the scanner successfully reads a bar code, the white LED will flash and the scanner will beep once. If the white LED does not flash or the scanner does not beep once, then the bar code has not been successfully read. Steady White and Blue After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s white LED will remain on until the data can be transmitted. Alternating Blue and White Flashes This indicates the scanner is in program mode. A razzberry tone indicates that an invalid bar code has been scanned in this mode. Steady White, Blue Off This indicates the scanner may be waiting for communication from the host.
19
Page 24
SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure. Return the unit to an authorized service center for repair.
Flashing Blue and White and Two Razzberry Tones This indicates that the scanner has experienced a motor failure. Return the unit to an authorized service center for repair.
Continuous Razzberry Tone with Both LEDs Off If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an electronic failure. Return the unit to an authorized service center for repair.
Three Beeps - On Power Up If the scanner beeps three times on power up then, the nonvolatile memory that holds the scanner configuration has failed. Return the unit to an authorized service center for repair.
20 www.metrologic.com
Page 25
SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code.
Figure 9. Normal Depth of Field
* All specifications are subject to change without notice.
21
Page 26
SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code.
Figure 10. Reduced Depth of Field
* All specifications are subject to change without notice.
22 www.metrologic.com
Page 27
SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone
MINIMUM BAR CODE ELEMENT WIDTH A
B
C
D
E
F mm
.13
.15
.19
.25
.33
.66 mils
5.2
5.7
7.5
10
13
26
Figure 11. Normal Scan Zone by Bar Code Element Width
* All specifications are subject to change without notice. 23
Page 28
SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone
MINIMUM BAR CODE ELEMENT WIDTH A
B
C
D
E
F mm
.13
.15
.19
.25
.33
.66 mils
5.2
5.7
7.5
10
13
26
Figure 12. Reduced Scan Zone by Bar Code Element Width
* All specifications are subject to change without notice.
24 www.metrologic.com
Page 29
SCANNER OPERATION IR Activation Range* QuantumE’s default power save mode† is Laser OFF. This power save mode turns the laser off after a configured period of non-use. Any movement detected by the IR in the activation area will cause the scanner to exit power save mode. The laser will automatically turn back on preparing the scanner for bar code recognition, decoding and transmission.
Figure 13. IR Activation Range
* All specifications are subject to change without notice. †
Refer to the MetroSelect Configuration Guide (00-02407) for additional information on configurable power save modes.
25
Page 30
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 46.
Symptoms
Possible Cause(s)
Solution
All Interfaces The unit has no LEDs, beeper or motor spin.
No power is being supplied to the scanner.
Check the transformer, outlet and power strip. Make sure the cable is plugged into the scanner.
The unit has no LEDs and/or beeper.
No power is being supplied to the scanner from host.
Some host systems cannot supply enough current to power the IS3480. Use the power supply included with the scanner.
There are multiple scans upon presentation of code.
The same symbol timeout is set too short.
Adjust the same symbol timeout for a longer time increment.
The beeper is disabled.
Enable the beeper.
No tone is selected.
Select a tone.
The unit is trying to scan a particular symbology that is not enabled.
UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected
The unit powers up but does not beep.
The unit powers up but does not scan and/or beep.
The unit scans but the data transmitted to the host is incorrect. 26
The scanner has been programmed for a character length lock, or a minimum length and bar code being scanned does not satisfy the configured criteria. The scanner’s data format does not match the host system requirements.
www.metrologic.com
Verify that the bar code that is being scanned falls into the criteria. Typical of Non-UPC/EAN codes. The scanner defaults to a minimum of 4 character bar code. Verify that the scanner’s data format matches the format required by the host. Make sure that the scanner is connected to the proper host port.