Page 11

INSTALLATION RS485“ or OCIA 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS3480.

3.

Connect the other end of the MVC cable to the host device.

4.

Turn on the host device.

Figure 5.

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

See page 5.

“

Applicable for IBM® Host applications.

7

Page 12

INSTALLATION Keyboard Wedge 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480.

3.

Disconnect the keyboard from the host device.

4.

Connect the “Y” end of the PowerLink cable to the keyboard and the keyboard port on the host device. If necessary, use the male/female adapter cable supplied with the scanner for proper connections.

5.

Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

6.

Connect AC power to the transformer.

7.

Turn on the host device.

Figure 6.

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED. Powering the IS3480 directly from the host device can sometimes cause interference with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port. For this reason, Metrologic recommends using an external power supply. For additional information, contact a Metrologic customer service representative.

See page 5.

8 www.metrologic.com

Page 13

INSTALLATION Stand-Alone Keyboard 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480.

3.

Connect the other end of the PowerLink cable to the keyboard port on the host device.

4.

Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

5.

Connect AC power to the transformer.

6.

Turn on the host device.

Figure 7.

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED. Powering the IS3480 directly from the host device can sometimes cause interference with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port. For this reason, Metrologic recommends using an external power supply. For additional information contact a Metrologic customer service representative.

See page 5.

9

Page 14

INSTALLATION Low Speed USB (Integrated) 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-pin socket on the IS3480.

3.

Plug the other end of the USB interface cable into the host device’s USB port.

4.

Turn on the host device. As a default, the IS3480-38 leaves the factory with USB Keyboard Emulation Mode enabled. For information on configuring the IS3480-38 for USB Serial Emulation Mode, please refer to Section P: Low Speed USB in the MetroSelect Configuration Guide (MLPN 00-02407).

Figure 8.

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED.

Plugging the scanner into the USB port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

See page 5.

10 www.metrologic.com

Page 15

INSTALLATION Notes for Laser Emulation IS3480-104 Only The IS3480-104 leaves the factory with the Laser Emulation Mode enabled. If the Recall Defaults bar code is scanned while reconfiguring the scanner, the laser emulation mode will no longer be enabled. Scan the following bar code to re-enable the laser emulation interface. This feature is only supported for IS3480-104 models. Enable Laser Emulation Mode

³

9

9

9

9

7

9

11

Page 16

SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the IS3480. •

The primary scan pattern mode is the default scan pattern active when the scanner starts.

•

The secondary scan pattern mode is activated by pressing the button located on the side of the scanner. This mode is also referred to as the button mode. For additional information on QuantumE’s button modes and an example of each, please refer to Configurable Button Functions below. The scanner returns to the primary scan pattern mode after a double click of the button or if the unit has not scanned a bar code for the duration of a pre-configured time limit.

Each pattern mode can be configured to use one of three scan patterns listed below. Please refer to the MetroSelect Configuration Guide for information on changing the default scan pattern settings. • • • all scan lines on (omnidirectional reading) single-line (menu reading) horizontal raster If CodeGate is enabled, it will apply to the secondary pattern mode when scanning. For detailed information on CodeGate and the button refer to the Configurable Button Functions.

Configurable Button Functions The button on the side of the IS3480 can be configured to function in one of four modes. • Button Click Mode, with CodeGate Enabled (Default) •

Button Click Mode, with CodeGate Disabled

•

Button Hold Mode, with CodeGate Enabled

•

Button Hold Mode, with CodeGate Disabled

The following pages include examples of how the button will function when the unit has been configured to operate in each of the four button modes.

12 www.metrologic.com

Page 17

SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured.

1.

The primary scan pattern is active when the scanner starts.

2.

To activate the secondary scan pattern, press and release the button.

3.

To decode and transmit the bar code, press and release the button. The scanner will beep once.

4.

To reactivate the primary scan pattern, double click the button or after 10-seconds of no-scanning the unit will automatically reactivate the primary pattern.

13

Page 18

SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured.

14 www.metrologic.com

1.

The primary scan pattern is active when the scanner starts.

2.

To activate the secondary scan pattern, press and release the button.

3.

The unit will beep once as it decodes and transmits the bar code.

4.

To reactivate the primary scan pattern, double click the button or after 10-seconds of no-scanning the unit will automatically reactivate the primary pattern.

Page 19

SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured.

1.

The primary scan pattern is active when the scanner starts.

2.

To activate the secondary scan pattern, press and hold the button.

3.

To scan the bar code, align the laser line over the bar code while continuing to hold down the button.

4.

To transmit the bar code, release the button. The scanner will beep once.

5.

To scan and transmit additional bar codes, repeat steps 2 through 4.

6.

The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field.

15

Page 20

SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the unit’s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured.

16 www.metrologic.com

1.

The primary scan pattern is active when the scanner starts.

2.

To activate the secondary scan pattern, press and hold the button.

3.

To scan and transmit the bar code, align the laser line over the bar code while continuing to hold down the button. The scanner will beep once to indicate the bar code has been scanned and transmitted.

4.

The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field.