The text of a manual · part 1 of 6

IS3480 QuantumE Scan Engine Installation and User's Guide, pages 1 to 10

Pages 1 to 10 of 56: IS3480 QuantumE ® Scan Engine; Manual Date Code

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic QuantumE IS3480

Page 1 read from a scan by OCR; it may hold reading errors

®Metrologic:

We really work for you.™

IS3480 QuantumE® Scan Engine

Installation and User’s Guide

Page 2

Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc. or their respective companies.

Page 3

TABLE OF CONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessories................................................................................. 2 Maintenance..................................................................................................... 3 Scanner Components....................................................................................... 4 Cable Removal................................................................................................. 4 Caution and Serial Number Labels................................................................... 5 Mounting Specifications ................................................................................... 5 Installation RS232, RS232 TTL, Light Pen or Laser Emulation .......................................... 6 RS485 or OCIA ................................................................................................ 7 Keyboard Wedge.............................................................................................. 8 Stand-Alone Keyboard ..................................................................................... 9 Low Speed USB (Integrated).......................................................................... 10 Notes for Laser Emulation .............................................................................. 11 Scanner Operation Configurable Primary and Secondary Scan Pattern Modes ........................... 12 Configurable Button Functions ....................................................................... 12 Sweet Spot Mode ........................................................................................... 17 Indicators Audible ....................................................................................................... 18 Visual ......................................................................................................... 19 Failure ........................................................................................................ 20 Depth of Field Specifications Normal Scan Zone ..................................................................................... 21 Reduced Scan Zone................................................................................... 22 iii

Page 4

TABLE OF CONTENTS Depth of Field by Bar Code Element Width Normal Scan Zone ..................................................................................... 23 Reduced Scan Zone................................................................................... 24 IR Activation Range........................................................................................ 25 Troubleshooting Guide ....................................................................................... 26 Design Specifications ......................................................................................... 29 Applications and Protocols ................................................................................. 31 Default Settings - Communication Parameters................................................... 32 Upgrading the Firmware ..................................................................................... 37 Scanner and Cable Terminations ....................................................................... 38 Regulatory Compliance Safety ............................................................................................................. 43 EMC ............................................................................................................... 44 Limited Warranty ................................................................................................ 46 Patents ............................................................................................................... 47 Index .................................................................................................................. 48 Office Locations and Contact Information .......................................................... 50 iv

Page 5

INTRODUCTION ®

QuantumE is a miniature, omni-directional scanning engine with optional singleline scanning capability. The self-contained device is fully enclosed eliminating the need for an external window or custom enclosure. It is designed for use in OEM equipment such as price lookup systems and kiosks. QuantumE s slim design makes it ideal for integration and use with flat-screens. Key Product Features •

Fully Automatic Scanning Operation

•

Custom Configurable Scan Pattern

•

User-Replaceable Single Cable Interface to Host (PowerLink Compatible)

•

Decoding of All Standard 1D, RSS-14, RSS Limited and Expanded Bar Codes

•

Data Editing

•

Seven Beeper Tones

•

Configurable Depth of Field

•

Flash - Upgradeable Firmware

•

CodeGate®

•

Sunrise 2005 Compliant

SCANNER

INTERFACE

IS3480-9

OCIA and RS232 Transmit/Receive

IS3480-11

RS485“ and Full RS232

IS3480-38

RS232 Low Speed USB, Keyboard Emulation or Serial Emulation

IS3480-41

RS232/Light Pen Emulation

IS3480-47

Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive

IS3480-104

RS232 TTL, Laser Emulation

“

Applicable for IBM® Host applications.

1

Page 6

INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No.

Description

IS3480

QuantumE Scanner

00-02026

IS3480 Installation and User’s Guide *

00-02407

MetroSelect® Configuration Guide *

* Guides also available for download at www.metrologic.com.

OPTIONAL ACCESSORIES Part No.

Description

AC to DC Power Transformer - Regulated 5.2VDC @ 1A output. 46-00525

90VAC to 255VAC United States, Canada and Japan

46-00526

90VAC to 255VAC Continental European

46-00527

90VAC to 255VAC United Kingdom

46-00528

90VAC to 255VAC Australia

46-00529

90VAC to 255VAC China

46-00530

90VAC to 255VAC India

59-59000-3 (default)

PowerLink cable with built in power jack straight cord, short strain relief

53-53000-3 (optional)

PowerLink cable with built in power jack coiled cord, long strain relief

**

Contact a Metrologic customer service representative for additional information on the MVC cable series and the host connections available.

MVC**

Metrologic Voltage Converter Cable ±12VDC to +5.2VDC

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s customer service department at 1-800-436-3876.

2 www.metrologic.com

Page 7

INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No.

Description

59-59002x-3

Keyboard Wedge PowerLink cable

59-59020x-3

Stand Alone Keyboard PowerLink cable

59-59235x-N-3

Low Speed USB Non-Locking Communication Cable straight cord, short strain relief

35-35959

Utility Flex Cable

59-59249x-N-3

Communication Cable, Host end Not Terminated straight cord, short strain relief

REPLACEMENT PARTS Part No. 36-01822x-3

Description Rubber Utility Seal

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s customer service department at 1-800-436-3876.

Maintenance Smudges and dirt on the unit's window can interfere with the unit's performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, nonabrasive cleaning cloth then gently wipe the window clean. If the unit's case requires cleaning, use a mild cleaning agent that does not contain strong oxidizing chemicals. Strong cleaning agents may discolor or damage the unit's exterior.

3

Page 8

INTRODUCTION Scanner Components

Figure 1a. Scanner Components

ITEM NO. 1

DESCRIPTION Utility Connector Located Under Rubber Seal The rubber seal protecting the utility connector should only be removed if the utility connector is to be used.

2

10-Pin RJ45, Female Socket

3

Blue, White and Yellow LED Indicators

4

Red Output Window (Laser Aperture)

5

Pin Hole for Cable Release

6

Speaker

7

Three M2.5 x 0.45 Threaded Mounting Points

8

Two M2.5 x 0.45 Threaded Mounting Points

9

Button

Cable Removal 1.

Locate the small ‘pinhole’ on the side of the QuantumE near the cable (item 5 in figure 1a).

2.

Bend an ordinary paperclip into the shape shown.

3.

Insert the paperclip (or other small metallic pin) into the ‘pinhole’.

4.

There will be a faint ‘click’ when the cable lock is released. Pull gently on the strain-relief of the PowerLink cable to remove it from the scanner.

4 www.metrologic.com

Figure 1b.

Page 9

INTRODUCTION Caution and Serial Number Labels

Figure 2. Caution To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source.

Mounting Specifications

Figure 3.

5

Page 10

INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480.

3.

Connect the 9-pin female end of the PowerLink cable to the host device. Note: Skip to step 6 if receiving power from the host device.

4.

Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

5.

Connect AC power to the transformer.

6.

Turn on the host device.

Figure 4.

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

See page 5.

6 www.metrologic.com