Page 31
TROUBLESHOOTING GUIDE Symptoms
Possible Cause(s)
Solution
The scanner is configured to support some form of host handshaking but is not receiving the signal.
If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.
The bar code may have been printed incorrectly.
Check if it is a check digit, character or border problem.
The scanner is not configured correctly for the type of bar code.
Check if check digits are set properly.
The minimum symbol length setting does not work with the bar code.
Check if the correct minimum symbol length is set.
During power up the unit beeps three times.
There is a non-volatile RAM failure.
Contact a Metrologic service representative.
During power up the unit razzes continuously.
There has been a diagnostic failure.
Contact a Metrologic service representative.
There is a VLD failure.
Contact a Metrologic service representative.
There is a scanner motor failure.
Contact a Metrologic service representative.
All Interfaces The unit scans a bar code, but locks up after the first scan (the white LED stays on).
Scanner beeps at some bar codes and NOT for others of the same bar code symbology.
During power up the unit razzes once and the blue LED flashes. During power up the unit razzes twice and both LEDs flash.
27
Page 32
TROUBLESHOOTING GUIDE Symptoms
Possible Cause(s)
Solution
RS232 Only The unit powers up OK and scans OK but does not communicate properly to the host.
The com port at the host is not working or is not configured properly. The cable is not connected to the proper com port.
Check to make sure that the baud rate and parity of the scanner and the communication port match and that the program is looking for RS232 data.
The com port is not operating properly.
The host is The scanner and host receiving data may not be configured but the data does for the same interface. not look correct. The intercharacter delay needs to be Characters are added to the being dropped. transmitted output.
Check that the scanner and the host are configured for the same interface. Add some intercharacter delay to the transmitted output by using the MetroSelect Configuration Guide (MLPN 00-02407).
Keyboard Wedge Only The unit scans the bar code but there is no data.
The unit scans but the data is not correct.
The unit may not be configured correctly.
Make sure the scanner is configured for the appropriate mode. Make sure that the proper PC type (ie. AT or PS2) is selected.
The unit may not be configured correctly.
Verify correct country code and data formatting are selected. Adjust the intercharacter delay.
The unit is not transmitting each character.
The unit may not be configured correctly.
Increase the interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try both settings.
Alpha characters The computer is in show as lower caps lock mode. case.
Enable caps lock detect setting of the scanner to detect whether the PC is operating in caps lock.
Everything works except for a couple of characters.
Try operating the scanner in Alt Mode.
28
These characters may not be supported by the current country’s key look up table.
www.metrologic.com
Page 33
DESIGN SPECIFICATIONS IS3480 Operational Light Source: Laser Power:
Visible Laser Diode (VLD) @ 650 nm 1.1 mW
Normal Depth of Field:
25 mm - 280 mm (1"- 11")
Reduced Depth of Field:
25 mm - 150 mm (1"- 6")
0.33 mm (13 mil) bar code
Omni Scan Scan Speed: No. of Scan Lines:
1650 scan lines per second 20
Single-Line Scan Speed: No. of Scan Lines:
80 scan lines per second 1
Raster Scan Speed: No. of Scan Lines
4
Motor Speed:
5000 RPM
Min Bar Width:
0.127 mm (5.0 mil)
Decode Capability:
All standard 1-D bar codes including RSS-14, RSS-Expanded, and RSS-14 Limited
System Interfaces:
RS232, Keyboard Wedge, Stand-Alone Keyboard, Light Pen Emulation, RS485“, Low Speed USB (Keyboard Emulation /Serial Emulation), Laser Emulation, RS232 TTL
Print Contrast: No. Characters Read: Beeper Operation: Indicators (LED):
“
320 scan lines per second
35% minimum reflectance difference Up to 80 data characters Maximum number will vary based on symbology and density. 7 tones or no beep Blue = laser on, ready to scan White = good read, decoding
®
Applicable for IBM Host applications.
Specifications subject to change without notice.
29
Page 34
DESIGN SPECIFICATIONS IS3480 Mechanical Width:
63 mm (2.48")
Depth:
50 mm (1.97")
Height:
68 mm (2.68")
Weight:
6 oz (170 g)
Electrical Voltage Supply:
5VDC ± 0.25V
Operating Power:
1.375 W
Standby Power:
1.0 W
Operating Current:
275 mA typical at 5VDC
Standby Current:
200 mA typical at 5VDC
DC Transformers:
Class II; 5.2VDC @ 1A
For regulatory compliance information, see pages 43 – 45.
Environmental Operating Temperature:
-20°C to 40°C (-4°F to 104°F)
Storage Temperature:
-40°C to 60°C (-40°F to 140°F)
Humidity: Contaminants: Ventilation:
5% to 95% relative humidity, non-condensing Sealed to resist airborne particulate contaminants None required
Specifications subject to change without notice.
30 www.metrologic.com
Page 35
APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER
VERSION IDENTIFIER
IS3480
“
COMMUNICATION PROTOCOL(S)
9
OCIA and RS232 Transmit/Receive
11
RS485“ and Full RS232C
38
RS232 Low Speed USB, Keyboard Emulation or Serial Emulation
41
Full RS232C/Light Pen Emulation
47
Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive
104
RS232 Transistor to Transistor Logic (TTL), Laser Emulation
Applicable for IBM® Host applications.
The IS3480 scanner with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. Many RS232 configurable functions (e.g. formatting) available in other Metrologic scanners are also available as keyboard wedge functions. The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • •
** AT (includes IBM® PS2 models 50, 55, 60, 80) IBM PS2 (includes models 30, 70, 8556)
Keyboard Country Type • • • • •
USA ** Belgium French German Hungarian
• • • • •
**
Default setting. For a complete list of default settings, see Default Settings Communication Parameters starting on page 32 of this guide. Refer to the MetroSelect® Configuration Guide (MLPN 00-02407) or MetroSet2’s help files for information on how to change the default settings.
Italian Japanese Russian Cyrillic Slovenian Spanish
• • • •
Swiss Swedish/Finnish Turkish United Kingdom
31
Page 36
DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Not every interface supports every parameter. If the interface supports a parameter listed in the charts on the following pages, a check mark ( ) will appear. RS232* PARAMETER
DEFAULT OCIA USB
UPC/EAN
*
Code 128
*
Code 93
*
Codabar
*
Interleaved 2 of 5 (ITF)
*
MOD 10 Check on ITF Code 11
*
Code 39 Full ASCII Code 39 MOD 43 Check on Code 39 MSI-Plessey MSI-Plessey 10/10 Check Digit MSI-Plessey MOD 10 Check Digit Paraf Support ITF Symbol Lengths
Variable
Minimum Symbol Length Symbol Length Lock
4 None
RSS14 Enable RSS14 ID “]e0”
*
RSS14 App ID “01”
*
RSS14 Check Digit
*
RSS Expanded Enable “
®
Applicable for IBM Host applications.
32 www.metrologic.com
OR
RS232 TTL
LIGHT RS485“ KBW PEN
LASER EMULATION
Page 37
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER
DEFAULT OCIA USB
OR
RS232 TTL
LIGHT RS485“ KBW PEN
LASER EMULATION
*
Expanded ID “]e0” RSS Limited Enable RSS Limited ID “]e0”
*
RSS Limited App ID “01”
*
RSS Limited Check Digit
*
Bars High as Code 39
*
Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS
*
DTS/NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone
Normal
Beep/Transmit Sequence
Before Transmit
Communication Timeout
None
Razzberry Tone on Timeout Three Beeps on Timeout No Beeps on Timeout
*
Enter Power Save Mode
10 mins.
Same Symbol Rescan Timeout: 500 msecs Programmable in 50 msec steps (MAX 6.35 seconds)
*
Intercharacter Delay Programmable in 1 msec steps (MAX 255 msecs)
1 msecs 10 msecs in KBW
Number of Scan Buffers
1
“
®
Applicable for IBM Host applications.
33
Page 38
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER
DEFAULT OCIA USB
Transmit UPC-A Check Digit
*
Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 Transmit UPC-A Number System
*
Transmit UPC-A Manufacturer ID#
*
Transmit UPC-A Item ID#
*
Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop/Start Characters Transmit Mod 10/ITF Transmit MSI-Plessey Check Characters Parity
Space
Baud Rate
9600
8 Data Bits 7 Data Bits
*
Stop Bits
2
Transmit Sanyo ID Characters “
®
Applicable for IBM Host applications.
34 www.metrologic.com
OR
RS232 TTL
LIGHT RS485“ KBW PEN
LASER EMULATION
Page 39
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* LIGHT RS485“ KBW PEN
LASER EMULATION
Two Digit Supplements as code 39 as code 39
Five Digit Supplements as code 39 as code 39
Bookland as code 39 as code 39
PARAMETER
DEFAULT OCIA USB
OR
RS232 TTL
Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Transmit AIM ID Characters STX Prefix ETX Suffix Carriage Return
*
Line Feed - disabled by default in KBW
*
Tab Prefix Tab Suffix “DE” Disable Command “FL” Laser Enable Command DTR Handshaking Support RTS/CTS Handshaking
*
Character RTS/CTS Message RTS/CTS XON/XOFF Handshaking ACK/NAK
977 (2 digit) Supplemental Requirement “
®
Applicable for IBM Host applications.
35
Page 40
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER
DEFAULT OCIA USB
Supplements are not Required
*
Two Digit Redundancy
*
OR
RS232 TTL
LIGHT LASER RS485“ KBW PEN EMULATION
Five Digit Redundancy 100 msec to Find Supplement Programmable in 100msec steps (MAX 800 msec)
* as code 39
Coupon Code 128 Programmable Code Lengths
7 avail.
Programmable Prefix Characters
10 avail.
Programmable Suffix Characters
10 avail.
Prefixes for individual Code Types Editing Inter Scan-Code Delay Programmable (100 µsec steps)
800 µsec
Function/Control Key Support Minimum Element Width Programmable in 5.6 µsec steps Normal Depth of Field
1 msec
*
Reduced Depth of Field Sweet Spot Mode “
®
Applicable for IBM Host applications.
36 www.metrologic.com as code 39