Page 19

SCANNER OPERATION Default Modes of Operation There are two default modes of operation available with the MS9590. 1.

In-Stand, Automatic Activation Mode • The laser is activated upon object detection in the IR activation area. • Bar code data is automatically decoded and transmitted.

2.

Out-of-Stand, Manual Activation Mode • The trigger (CodeGate) activates the laser. • Bar code data is scanned and transmitted while the trigger is held down.

Scanning with the Manual Activation Mode 1.

Aim the scanner at the bar code.

2.

Pull and hold down the trigger to turn on the laser, scan, and transmit the bar code.

3.

The scanner will beep and flash the white LED once to indicate a successful scan and transmission.

Figure 14.

Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. The output window should be routinely cleaned with glass cleaner sprayed onto a lint free, non-abrasive cloth.

15

Page 20

INDICATORS Audible During operation, the MS9590 provides audible feedback that indicates the status of the scanner and latest scan. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the beeper tone, refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help files. One Beep When the scanner first receives power, the blue LED will turn on, the white LED will flash, and the scanner will beep once. The scanner is ready to scan. When the scanner successfully reads a bar code, the white LED will flash and the scanner will beep once. Three Beeps During Operation When entering the configuration mode, the white LED will flash while the scanner simultaneously beeps three times. When exiting the configuration mode, the scanner will beep three times and the white LED will stop blinking. Three beeps can also indicate a communication timeout during normal scanning mode if the scanner is configured to give this indication. During Start-up This is a failure indicator. Refer to “Failure Modes” on page 18. Three Beeps When using the single-code-configuration method, the scanner will sound a 3-combination tone (a single beep then a short pause followed by, a high tone, and a low tone). This beep sequence signals that the single configuration bar code has successfully configured the scanner. Razzberry Tone This tone indicates a type of failure. Refer to “Failure Modes" on page 18. When in configuration mode, a short razzberry tone will sound if an invalid bar code is scanned.

16

Page 21

INDICATORS Visual The MS9590 has three LED indicators (blue, white, and yellow) located on the head of the scanner. When the scanner is in operation, the flashing, or stationary activity of the LEDs indicates the status of the scanner and the current scan. Figure 15. LED Configuration

All LEDs are Off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. The scanner is in idle mode and CodeGate is enabled. Steady Yellow Indicates CodeGate mode is disabled. Steady Blue When the laser is active, the blue LED is illuminated. The blue LED will remain illuminated until the laser is deactivated (default mode only). Steady Blue and Single White Flash When the scanner successfully reads a bar code, the white LED will flash and the scanner will beep once. After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner's white LED will remain on until the data can be transmitted. Alternating Flashing of Blue and White During Operation This indicates the scanner is in configuration mode.

17

Page 22

INDICATORS Failure Modes One Razzberry Tone – On Power Up This indicates the scanner has experienced a flipper/motor failure. Return the scanner for repair to an authorized service center. Three Beeps – On Power Up If the scanner beeps 3 times on power up, verify the host and scanner are set to the same communication protocol. If the host and the scanner's communication protocol match, then, the non-volatile memory (NovRAM) that holds the scanner's configuration may have failed. Try to reconfigure the scanner. If the scanner does not respond after reconfiguring, return the scanner for repair to an authorized service center.

18

Page 23

CONFIGURATION MODES The MS9590 has three modes of configuration. •

Bar Codes The MS9590 can be configured by scanning the bar codes located in the MetroSelect® Single-Line Configuration Guide (MLPN 00-02544). This manual can be downloaded FREE at www.metrologic.com.

•

MetroSet®2 This user-friendly Windows-based configuration software allows you to simply ‘point-and-click’ at the desired scanner options. This software can be downloaded FREE at www.metrologic.com or set-up disks can be ordered by calling 1-800-ID-METRO.

•

Serial Configuration This mode of configuration is ideal for OEM applications. This mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single-Line Configuration Guide (MLPN 00-02544).

19

Page 24

UPGRADING THE FLASH ROM FIRMWARE The MS9590 VoyagerCG is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative‹ and Metrologic's MetroSet2 software‹‹. A personal computer running Windows 95 or greater with an available RS232 serial or USB port is also required to complete the upgrade. PowerLink Cable #54-54014 is required when using RS232 for the upgrade process. This cable can be ordered from Metrologic at 1-800-ID-METRO. Do not use the standard cable supplied with keyboard wedge or RS485 scanner interface kits. If using USB for the upgrade process, the standard USB Type A cable provided with the scanner can be used.

To upgrade the firmware in the MS9590: 1.

Plug the scanner into a serial communication port on the host system.

2.

Start the MetroSet2 software.

3.

Click on the plus sign (+) next to POS Scanners to expand the supported scanner list.

4.

Choose the MS9590 VoyagerGS from the list.

5.

Click on the Configure VoyagerGS/9590 Scanner button.

6.

Choose Flash Utility from the options list located on the left side of the screen.

7.

Click on the Open File button in the Flash Utility window.

8.

Locate and open the flash upgrade file supplied by Metrologic.

9.

Select the COM port that the scanner is connected to on the host system.

10. Verify the settings listed in the Flash Utility window. 11. Click on the Flash Scanner button to begin the flash upgrade. 12. A message will appear on the screen when the upgrade is complete.

‹

‹‹

20

Metrologic's customer service department can be reached at 1-800-ID-METRO or 1-800-436-3876. MetroSet2 is available for download, at no additional cost, from http://www.metrologic.com/corporate/download.

Page 25

DEPTH OF FIELD

MINIMUM BAR CODE ELEMENT WIDTH A

B

C

D

E

F

G mm

.127

.15

.19

.26

.33

.48

.66 mils

5.0

5.7

7.5

10.4

13

19

26

Figure 16. Depth of Field vs. Bar Code Element Width

Specifications are subject to change without notice.

21

Page 26

IR ACTIVATION RANGE The MS9590 has an optional built in object detection sensor that instantly turns on the scanner's laser when an object is presented within the scanner's IR activation area. Refer to the MetroSelect Single-Line Configuration Guide for information on configurable IR activation range options.

Figure 17. Short and Long IR Activation Areas

Specifications are subject to change without notice.

22

Page 27

APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and the default communication protocol for the scanner. Scanner

Version Identifier

Communication Protocol(s)

14

RS232 - TXD, RXD, RTS, CTS, DTR, DSR

38

USB (Bi-Directional Serial Emulation Mode or Keyboard Emulation Mode), and RS232 Transmit/Receive

47

Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive

106

RS485, USB (Bi-Directional Serial Emulation Mode, Keyboard Emulation Mode or IBM OEM) and RS232 Transmit/Receive

MS9590

The MS9590 Keyboard Wedge Series (-47) is designed for keyboard emulation only. Many RS232 configurable functions available in other Metrologic scanners are also available as keyboard wedge functions. The following items are the most important selectable options specific to the keyboard wedge interface: Keyboard Type • •

® **AT (includes IBM PS2 models 50, 55, 60, 80) IBM PS2 (includes models 30, 70, 8556)

Keyboard Country Type • • • • •

**

**USA Belgian French German Hungarian

• • • • •

Italian Japanese Russian Cyrillic Slovenian Spanish

• • • •

Swiss Swedish/Finnish Turkish United Kingdom

Indicates a default setting. Refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for information on how to change the default settings.

23