Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 5

MS9590 VoyagerGS Single-Line Hand Held Laser Scanner Installation and User's Guide, pages 28 to 36

Pages 28 to 36 of 44

The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MS9590

Page 28

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. Symptoms

Possible Causes

Solution

All Interfaces

The unit has no LEDs, beep, or laser.

At power up, the unit beeps 3 times.

No power is being supplied to the unit.

Check the transformer, the outlet and power strip. Make sure the cable is plugged into the unit.

No power is being supplied to the unit from host.

Some host systems cannot supply enough current to power Voyager. A power supply may be needed.

The host and scanner are not set to the same communication protocol.

Set the host and scanner to the same communication protocol.

There is a nonvolatile RAM failure.

Contact a Metrologic service representative.

At power up, the unit emits a razz tone and the blue LED flashes.

The unit has experienced a VLD failure.

At power up, the unit emits a razz tone and both LEDs flash.

The unit has experienced a flipper/motor failure.

The unit scans, communicates, and beeps twice.

The same symbol timeout is set too short.

Adjust the same symbol timeout for a longer time.

The unit powers up, but does not beep.

The beeper may be disabled or no tone has been selected.

Enable beeper and select a tone.

The unit powers up, but does not scan and/or beep.

The unit is trying to scan a particular symbology that is not enabled.

UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected.

24

Contact a Metrologic service representative.

Page 29

TROUBLESHOOTING GUIDE Symptoms

Possible Causes

The unit powers up, but does not scan and/or beep.

The bar code being scanned does not satisfy the configured criteria for character length lock or minimum length.

Verify that the bar code being scanned falls into the configured criteria.

The unit scans a bar code, but locks up after the first scan and the white LED stays on.

The unit is configured to support some form of host handshaking but is not receiving the signal.

If the unit is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.

The unit scans, but the data transmitted to the host is incorrect.

The unit’s data format does not match the host system’s requirements.

Verify that the unit’s data format matches that required by the host. Make sure that the unit is connected to the proper host port.

The print quality of the bar code is suspect.

Check the print mode. The type of printer could be the problem. Change the print settings.

The aspect ratio of the bar code is out of tolerance.

i.e. Change to econo mode or high speed.

The unit beeps at some bar codes but NOT for others of the same bar code symbology.

The unit scans the bar code but there is no data.

The bar code may have been printed incorrectly. The unit is not configured correctly for the type of bar code being scanned.

Solution

The scanner defaults to a minimum of 3 character bar code.

Check if it is a check digit/character/or border problem.

The minimum symbol length setting does not work with the bar code.

Check if the correct minimum symbol length is set.

The unit’s configuration is not correct.

Make sure the scanner is configured for the appropriate mode.

25

Page 30

TROUBLESHOOTING GUIDE Symptoms

Possible Causes

Solution

The unit scans but the data is not correct.

The unit’s configuration is not correct.

Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct country code and data format is selected. Adjust the intercharacter delay symptom.

The unit is transmitting each character twice.

The unit’s configuration is not correct.

Increase the interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.

Alpha characters show as lower case.

The computer is in Caps Lock mode.

Enable the Caps Lock detect feature of the scanner to detect whether the PC is operating in Caps Lock.

Everything works except for a couple of characters.

These characters may not be supported by that country’s key look up table.

Try operating the scanner in Alt mode.

The com port at the host is not working or not configured properly.

Check to make sure that the baud rate and parity of the scanner and the communication port match and that the program is looking for “RS232” data.

The cable is not connected to the proper com port.

Check to make sure that the unit is connected to the correct com port on the host device.

The host is receiving data but the data does not look correct.

The scanner and host may not be configured for the same interface parameters.

Check that the scanner and the host are configured for the same interface parameters.

Characters are being dropped.

Inter-character delay needs to be added to the transmitted output.

Add some inter-character delay to the transmitted output by using the MetroSelect Single-Line Configuration Guide.

The unit powersup OK and scans OK but does not communicate properly to the host.

26

Page 31

DESIGN SPECIFICATIONS MS9590 Series Specifications OPERATIONAL Light Source:

Visible Laser Diode 650 nm ± 10 nm

Laser Power:

0.809 mW (peak)

Pulse Duration: Depth of Scan Field:

560 µsec 0 mm - 305 mm ( 0" – 12" ) with a 0.330 mm (13 mil) bar code 50 mm (1.97") @ face

Width of Scan Field:

300 mm (11.81") @ 305 mm (12")

Scan Speed:

100 scan lines per second

Scan Pattern:

Single Scan Line

Minimum Bar Width: Infrared Activation:

0.330 mm (13 mil) bar code

0.127 mm (5.0 mil) Long Range

0 mm – 279 mm ± 50 mm ( 0" - 11" ± 1.97")

Short Range 0 mm – 140 mm ± 25 mm ( 0" - 5.5" ± 0.98")

Decode Capability:

Autodiscriminates all standard 1D bar codes for others call a Metrologic service representative

System Interfaces:

RS232, Keyboard Wedge, Stand-Alone Keyboard, RS485, USB

Print Contrast:

35% minimum reflectance difference

Number Characters Read:

Up to 80 data characters. The maximum number will vary based on symbology & density.

Beeper Operation:

7 tones or no beep

Visual Indicators: Default Settings

Blue LED laser on, ready to scan

White LED good read

Yellow LED

ON, CodeGate is Disabled OFF, CodeGate is Enabled

Specifications are subject to change without notice.

27

Page 32

DESIGN SPECIFICATIONS MS9590 Series Specifications MECHANICAL Height H1:

160 mm (6.30")

2

H:

41 mm (1.60")

1

65 mm (2.56")

W2:

25.4 mm (1.00")

Depth:

100 mm (3.93")

Weight:

150g

Width W :

ELECTRICAL Input Voltage: Power:

Current: DC Transformers:

5VDC ± 0.25V Operating = 650 mW typical Standby = 375 mW typical Operating = 130 mA @ 5VDC typical Standby = 75 mA @ 5VDC typical Class 2; 5.2V @ 1A

For regulatory compliance information see pages 33 – 35.

ENVIRONMENTAL Temperature: Humidity: Light Levels: Shock: Contaminants:

Operating = 0°C to 40°C (32°F to 104°F) Storage = -40°C to 60°C (-40°F to 140°F) 5% to 95% relative humidity, non-condensing Up to 4842 Lux (450 footcandles) Designed to withstand 1.5 m (5 ft.) drops Sealed to resist airborne particulate contaminants

Specifications are subject to change without notice.

28

Page 33

SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS9590 scanner interfaces terminate to a 10-pin modular jack. The serial number label indicates the interface enabled when the scanner is shipped from the factory. MS9590-14 RS232

Pin 1 2 3 4 5 6 7 8 9 10

Function Ground Transmit RS232 Output Receive RS232 Input RTS RS232 Output CTS RS232 Input DTR RS232 Input Reserved DSR TTL Output +5VDC Shield Ground

Figure 18.

MS9590-47

MS9590-38,

Keyboard Wedge and Stand-Alone Keyboard

USB

Pin

Function

Pin

Function

1 2 3 4 5 6 7 8 9 10

Ground Transmit RS232 TTL Output Receive RS232 TTL Input PC Data TTL PC Clock TTL KB Clock TTL Reserved KB Data TTL PC +5VDC Shield Ground

1 2 3 4 5 6 7 8 9 10

Ground Transmit RS232 TTL Output Receive RS232 TTL Input Reserved Reserved D+ PC +5V Detect Input DPC +5V Power Shield Ground

MS9590-106 RS485, USB

Pin

Function

1 2 3 4 5 6 7 8 9 10

Ground Transmit RS232 TTL Output Receive RS232 TTL Input IBM + IBM D+ PC +5V Detect Input DPC +5V Power Shield Ground

29

Page 34

SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) RS232 PowerLink Cable 53-53000x-3 Pin

Function

1

Shield Ground

2

RS232 Transmit Output

3

RS232 Receive Input

4

DTR Input/Light Pen Source

5

Signal Ground

6

Light Pen Data (DSR Out for -14 interfaces)

7

CTS Input

9-Pin Female, D-Type

8

RTS Output

9

+5VDC

USB Cables 53-53813x-N-3, 53-53809x-N-3 Pin

Function

1

PC +5V/V_USB

2

D-

3

D+

4

Ground

Locking Type A

Non-Locking Type A

Shield Shield Stand-Alone Keyboard Cable 53-53820x-N-3 Pin 1 2 3 4 5 6

30

Function PC Data No Connect Power Ground +5VDC PC Power to KB PC Clock No Connect

6-Pin Male Mini-DIN Connector

Page 35

SCANNER AND CABLE TERMINATIONS Cable Connector Configuration (Host End) Keyboard Wedge Cable 53-53802x-3 Pin 1 2 3 4 5 Pin 1 2 3 4 5 6

Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect

5-Pin DIN, Female

6-Pin DIN, Male

Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. Keyboard Wedge Adapter Cable Pin 1 2 3 4 5 Pin 1 2 3 4 5 6

Function PC Clock PC Data No Connect Power Ground +5 Volts DC Function Keyboard Data No Connect Power Ground +5 Volts DC Keyboard Clock No Connect

5-Pin DIN, Male

6-pin Mini DIN, Female

31

Page 36

LIMITED WARRANTY The MS9590 VoyagerGS™ series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility and at its Suzhou, China facility. The MS9590 series scanners have a five (5) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS9590 series scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of product or refund of product price at the sole discretion of Metrologic. Faulty equipment must be returned to one of the following Metrologic repair facilities: Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China. To do this, contact the appropriate Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgment of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN.

CORPORATE HEADQUARTERS, NORTH AMERICA

METROLOGIC EUROPEAN REPAIR CENTER (MERC)

Metrologic Instruments, Inc. 90 Coles Rd. Blackwood, NJ 08012-4683 Customer Service Department Tel: 1-800-ID-METRO Fax: 856-228-6673 Email: info@metrologic.com

Metrologic Eria Ibérica, SL C/Alfonso Gomez, 38-40, 1D 28037 Madrid Tel: +34 913 751 249 Fax: +34 913 270 437

MTLG AUTO ID INSTRUMENTS (SHANGHAI) CO., LTD Suzhou Sales Office BLK A, Room# 03/03-04 No.5 Xinghan Street, Xinsu Industrial Square China-Singapore Suahou Industrial Park, Suzhou, PRC Tel: 86-512-67622550 Fax: 86-512-67622560 Email: info@cn.metrologic.com

32