MS9590 VoyagerGS Single-Line Hand Held Laser Scanner Installation and User's Guide, pages 10 to 18

Pages 10 to 18 of 44

The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MS9590

Page 10

INTRODUCTION Labels Every MS9590 has a serial number label located on the underside of the scanner head and molded text on the scanner handle. The label and molded text provide important information such as the unit’s date of manufacture, serial number, CE and caution information. See Figure 4 for examples of these items and their location on the scanner.

Figure 4 . Molded Text and Serial Number Label

Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA-C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source.

6

Page 11

SCANNER INSTALLATION RS232 (-14) 1.

Turn off the host device.

2.

Plug the 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS9590. There will be an audible click when the connector lock engages.

3.

Connect the 9-pin D-type connector of the PowerLink cable to the proper COM port on the host device.

If the scanner is receiving power from the host system, skip to step #6. 4.

Plug the power supply into the power jack on the PowerLink cable. Check the AC in input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

5.

Connect AC power to the transformer.

6.

Turn on the host device.

Figure 5.

The scanner is shipped from the factory configured to set of default conditions. Plugging the scanner into a port on the host system does not guarantee that the scanned information will be communicated properly to the host device. The scanner and host device must use the same communication protocol. Please refer to the MetroSelect SingleLine Configuration Guide or the help files provided with MetroSet2 for instructions on changing the scanner’s factory default configuration.

See caution on page 6.

7

Page 12

SCANNER INSTALLATION RS485 (-106) 1.

Turn off the host device.

2.

Plug the 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS9590. There will be an audible click when the connector lock engages.

3.

Connect the other end* of the MVC cable to the host device.

4.

Turn on the host device.

5.

The blue LED on the scanner will turn on, the white LED will flash, and the scanner will beep once.

6.

Scan the bar code below to activate the RS485 interface.

³

9

9

9

9

9

5

Figure 6.

USB is the default communication protocol for an MS9590-106. If the recall defaults bar code is scanned after the unit has been configured for RS485, the scanner will revert to the USB default communication protocol. The bar code above will need to be rescanned to return the unit to the RS485 communication protocol. The scanner is shipped from the factory configured to set of default conditions. Plugging the scanner into a port on the host system does not guarantee that the scanned information will be communicated properly to the host device. The scanner and host device must use the same communication protocol. Please refer to the MetroSelect SingleLine Configuration Guide or the help files provided with MetroSet2 for instructions on changing the scanner’s factory default configuration.

See caution on page 6. * The type of host connection available on an MVC cable is application dependent. Contact a customer service representative at 1-800-ID-METRO for additional information on the MVC converter cable series. 8

Page 13

SCANNER INSTALLATION Keyboard Wedge (-47) 1.

Turn off the host device.

2.

Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the MS9590. There will be an audible click when the connector lock engages.

3.

Disconnect the host device's keyboard.

4.

Connect the "Y" ends of the cable to the keyboard and keyboard port on the host device. If necessary, use the male/female adapter cable supplied with the scanner cable to make the proper connections.

If the scanner is receiving power from the host system, skip to step #7. 5.

Plug the power supply into the power jack on the PowerLink cable. Check the AC in input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

6.

Connect AC power to the transformer.

7.

Turn on the host device.

Figure 7.

The scanner is shipped from the factory configured to set of default conditions. Plugging the scanner into a port on the host system does not guarantee that the scanned information will be communicated properly to the host device. The scanner and host device must use the same communication protocol. Please refer to the MetroSelect Single-Line Configuration Guide or the help files provided with MetroSet2 for instructions on changing the scanner’s factory default configuration. Powering the MS9590-47 directly from the host device may cause interference with the operation of the scanner or the host device. Not all host devices supply the same current through the keyboard port. Contact a Metrologic, customer service representative for information on available external power supplies.

See caution on page 6.

9

Page 14

SCANNER INSTALLATION Stand-Alone Keyboard (-47) 1.

Turn off the host system.

2.

Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the MS9590. There will be an audible click when the connector lock engages.

3.

Plug the other end of the cable into the host's keyboard port

If the scanner is receiving power from the host system, skip to step #6. 4.

Plug the power supply into the power jack on the PowerLink cable. Check the AC in input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

5.

Connect AC power to the transformer.

6.

Turn on the host device.

Figure 8.

The scanner is shipped from the factory configured to set of default conditions. Plugging the scanner into a port on the host system does not guarantee that the scanned information will be communicated properly to the host device. The scanner and host device must use the same communication protocol. Please refer to the MetroSelect Single-Line Configuration Guide or the help files provided with MetroSet2 for instructions on changing the scanner’s factory default configuration. Powering the MS9590-47 directly from the host device may cause interference with the operation of the scanner or the host device. Not all host devices supply the same current through the keyboard port. Contact a Metrologic, customer service representative for information on available external power supplies.

See caution on page 6.

10

Page 15

SCANNER INSTALLATION USB (-38 and -106)‹ 1.

Turn off the host system.

2.

Plug the 10-pin RJ45 end of the USB cable into the 10-pin socket on the MS9590. There will be an audible click when the connector lock engages.

3.

Plug the USB Type A end of the cable into the host's USB port.

4.

Turn on the host device.

Figure 9.

USB is the default communication protocol for the MS9590-106. Both the MS9590-38 and the MS9590-106 have USB Keyboard Emulation Mode enabled by default when shipped from the factory. Both the MS9590-38 and the MS9590-106 are configurable for Bi-Directional Serial Emulation mode. IBM OEM support is only available with the MS9590-106. Refer to the USB section in the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) for USB configuration bar codes. The scanner is shipped from the factory configured to set of default conditions. Plugging the scanner into a port on the host system does not guarantee that the scanned information will be communicated properly to the host device. The scanner and host device must use the same communication protocol. Please refer to the MetroSelect SingleLine Configuration Guide or the help files provided with MetroSet2 for instructions on changing the scanner’s factory default configuration.

See caution on page 6. ‹

The MS9590-38 and the MS9590-106 meet the requirements for Full Speed USB hardware. These interfaces also support all emulation types previously supported by Metrologic in Low Speed USB scanners.

11

Page 16

STAND Flex Stand Components (PN 46-00709)

Item

Item Description

Qty.

A

Cradle Coupler

1

B

Cradle

1

C

Flexible Shaft

1

D

Screw Cap

2

E

Stand Base

1

F

¼" - 20 x ⅜" Flat Head Phillips Screw, 100° Undercut

2

G

#8 Round Head Wood Screw

2

H

M3 -.5 x 20 mm, Pan Head Phillips Screw

1

J

M3 Flat Washer

1

K

M3 Split Lock Washer

1

L

Flexible Shaft Cover

1

Figure 10. Stand Components

12

Page 17 read from a scan by OCR; it may hold reading errors

STAND

Flex Stand Assembly (PN 46-00709)

%" - 20 x ¥%" Flat Head Front ‘Sid SE tf a 100° Undercut Screw

Cradle If M3 Flat Washer i] Screw Cap @ M3 Split Lock Washer

O.. Deere fin Pan Head, Phillips Screw

6 Screw Cap, Flexible Shaft Cover Cradle Coupler, Stand Base

Ya" - 20 x ¥%" Flat Head 7 Phillips 100° Undercut Screw aed |

Figure 11. Stand Assembly

13

Page 18

STAND Optional Flex Stand Fixed Mount (PN 46-00709) 1.

In the kit, two #8 wood screws have been provided for fixed mount applications.

2.

When choosing the stand location, make sure to consider the front orientation of the stand (indicated in Figure 12).

3.

On a centerline, drill two #39 pilot holes in the countertop spaced 125 mm (4.92") apart. The stand base can be used as a guide for the spacing of the pilot holes.

4.

Secure the stand base to the countertop with the two #8 wood screws provided.

Figure 12.

Figure 13. Stand Base Hole Pattern (Not to Scale)

14