Page 1

METROLOGIC INSTRUMENTS, INC.

MS9590 VoyagerGS™ Single-Line Hand Held Laser Scanner Installation and User's Guide

Page 2

Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc. or their respective companies.

Page 3

TABLE OF CONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessories................................................................................. 2 Scanner Components....................................................................................... 4 Cable Installation and Removal........................................................................ 5 Labels............................................................................................................... 6 Scanner Installation RS232 (-14)...................................................................................................... 7 RS485 (-106).................................................................................................... 8 Keyboard Wedge (-47) ..................................................................................... 9 Stand-Alone Keyboard (-47)........................................................................... 10 USB (-38 and -106) ........................................................................................ 11 Stand Flex Stand (PN 46-00709).............................................................................. 12 Components ............................................................................................... 12 Assembly.................................................................................................... 13 Optional Fixed Mount ................................................................................. 14 Scanner Operation Default Modes of Operation............................................................................ 15 Scanning with the Manual Activation Mode .................................................... 15 Maintenance................................................................................................... 15 Indicators Audible ........................................................................................................... 16 Visual ............................................................................................................. 17 Failure Modes................................................................................................. 18 Configuration Modes .......................................................................................... 19 Upgrading the Flash ROM Firmware .................................................................. 20 Depth of Field ..................................................................................................... 21 IR Activation Range............................................................................................ 22 Applications and Protocols ................................................................................. 23 ii

Page 4

TABLE OF CONTENTS Troubleshooting Guide ....................................................................................... 24 Design Specifications Operational..................................................................................................... 27 Mechanical ..................................................................................................... 28 Electrical......................................................................................................... 28 Environmental ................................................................................................ 28 Scanner and Cable Terminations Scanner Pinout Connections .......................................................................... 29 Cable Connector Configurations .................................................................... 30 Limited Warranty ................................................................................................ 32 Regulatory Compliance Safety ............................................................................................................. 33 EMC ............................................................................................................... 34 Patents ............................................................................................................... 36 Index .................................................................................................................. 37 Contact Information and Office Locations........................................................... 39 iii

Page 5

INTRODUCTION Product Overview Metrologic’s MS9590 VoyagerGS™ is the newest addition to the Voyager® series of hand-held laser scanners. The MS9590 is the first Voyager product to feature trigger scanning in its design. The VoyagerGS provides an aggressive solution for scanning all standard 1D bar codes in a new ergonomic form factor that maximizes comfort and reduces fatigue. Key product features include: •

Rapid scan speed of 100 scans per second

•

Extended depth of field

•

® CodeGate data transmission technology

•

Manual-trigger operation and automatic in-stand detection

•

Data formatting

•

® ® Easy configuration with MetroSelect bar codes and MetroSet 2 ® Windows compatible software

•

A 5-year limited warranty

MODEL

INTERFACE

MS9590 – 14

RS232 - TXD, RXD, RTS, CTS, DTR, DSR

MS9590 – 38

USB* and RS232 Transmit/Receive

MS9590 – 47

Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive

MS9590 – 106

RS485, USB** and RS232 Transmit/Receive

* Scanner model is configurable for Keyboard Emulation Mode or Bi-Directional USB Serial Emulation Mode. The default setting is Keyboard Emulation Mode. ** Scanner model is configurable for Keyboard Emulation Mode, Bi-Directional USB Serial Emulation Mode, or IBM OEM. The default setting is Keyboard Emulation Mode.

1

Page 6

INTRODUCTION Scanner and Accessories BASIC KIT Part #

Description

MS9590

MS9590 Bar Code Scanner

00-02544

MetroSelect Single-Line Configuration Guide*

00-05150

MS9590 Series Single-Line Hand Held Laser Scanner Installation and User’s Guide*

* Available for download on the Metrologic website - www.metrologic.com

OPTIONAL ACCESSORIES Part # 46-00709

Description Flex Stand

AC to DC Power Transformer- Regulated 5.2VDC @ 1A output. 46-00525

90VAC to 255VAC, United States, Canada and Japan

46-00526

90VAC to 255VAC, Continental European

46-00870

90VAC to 255VAC, United Kingdom

46-00528

90VAC to 255VAC, Australia

46-00529

90VAC to 255VAC, China

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor, or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.

2

Page 7

INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part #

Description

Cable Compatibility Warning Use only MS9590 compatible product cables from the list below. Damage may occur to the scanner if incompatible cables are used. Any damage incurred from incorrect cable usage will void the limited warranty shown on page 32. 53-53000x-3

RS232 PowerLink Cable with Built in Power Jack Black Coiled Cord with Long Strain Relief

53-53802x-N-3

Keyboard Wedge Cable with Adapter Cable Black Coiled Cord with Long Strain Relief

53-53820x-N-3

Stand-Alone Keyboard Cable Black Coiled Cord with Long Strain Relief

53-53813x-N-3

USB Cable, Locking Plus-Power™ Type A Black Coiled Cord with Long Strain Relief

53-53809x-N-3

USB Cable, Type A Black Coiled Cord with Long Strain Relief

MVC**

Metrologic Voltage Converter Cable ±12VDC to +5.2VDC for RS485 Applications

**

Contact a customer service representative for additional information on the MVC converter cable series and the host connections available.

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor, or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.

3

Page 8

INTRODUCTION Scanner Components

No.

Item Description

1

Window

Laser Aperture

2

Trigger

See How to use CodeGate on page 15

3

Cable Connection

10-pin RJ45, Female Socket, See Scanner Pinout Connections on page 29

4

Speaker

See Audible Indicators on page 16

5

White LED

See Visual Indicators on page 17

6

Blue LED

See Visual Indicators on page 17

7

Yellow LED

See Visual Indicators on page 17

8

Cable Release Pin-Hole

See The PowerLink Cable on page 5

Figure 1. Scanner Components

4

Page 9

INTRODUCTION Cable Installation and Removal Installation Important: If the cable is not fully latched, the unit can power intermittently.

Figure 2. Connecting the Cable

1. 2.

Plug the 10-pin RJ45 end of the cable into the 10-pin socket on the MS9590. There will be an audible click when the connector lock engages. Gently pull on the cable strain relief to insure the cable is securely installed.

Removal Before removing the cable from the scanner, Metrologic recommends that power to the host system be turned off. If the cable is a PowerLink cable, disconnect the power supply on the cable.

Figure 3. Releasing the Cable

1. 2. 3. 4.

Locate the small dimple on the handle of the unit near the cable connection. Bend an ordinary paperclip into the shape shown above in Figure 3. To release the cable lock, push the end of the paperclip through the rubber on the handle where the dimple is located. There will be an audible click when the connector lock releases. Pull gently on the strain-relief of the cable to separate the cable from the scanner.

5