Page 21

SCANNER OPERATION Visual Indicators The MS1690 has three LED indicators (yellow, white and blue) located on the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner. No LEDs are Illuminated The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. The scanner is in stand-by mode. Present a bar code to the scanner and the blue LED will turn on when the IR detects the object.

Figure 15.

Steady Yellow The yellow LED is illuminated when the scanner is in the stand. Steady Blue The blue LED is illuminated when the scanner is active and linear illumination is on or when the scanner is attempting to decode a barcode. Steady Blue and Single White Flash When the scanner successfully reads a bar code it will beep once and the white LED will turn on indicating data is being transmitted. If the scanner does not beep once and the white light does not turn on, then the bar code has not been successfully read. Steady White When the scanner successfully reads a bar code it will beep once and the white LED will turn on indicating data is being transmitted. After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s white LED will remain on until the data can be transmitted. Alternating Flashing of Blue and White This indicates the scanner is in configuration mode. A short razzberry tone indicates that an invalid bar code has been scanned while in this mode. Flashing Blue The blue LED will flash if the trigger is pressed while the scanner is in the in-stand presentation mode. The blue LED will stop flashing after a brief period of time. 17

Page 22

SCANNER OPERATION Failure Modes Long Razzberry Tone – During Power Up Failed to initialize or configure the scanner. If the scanner does not respond after reprogramming, return the scanner for repair. Short Razzberry Tone – During Scanning An Invalid bar code has been scanned when in configuration mode or the trigger has been pulled too fast.

18

Page 23

SCANNER OPERATION Depth of Field by Minimum Bar Code Element Width

Figure 16. Depth of Field by Minimum Bar Code Element Width

MINIMUM BAR CODE ELEMENT WIDTH 1D

PDF

A

B

C

D

E

F

G mm

.132

.19

.254

.33

.533

.254

.381 mils

5.2

7.5

10.4

13

21

10

15.9

Specifications are subject to change without notice.

19

Page 24

SCANNER OPERATION IR Activation Range The MS1690 has a built in object detection sensor that instantly turns on the scanner when an object is presented within the scanner’s IR activation Area.

Figure 17. IR Activation Area Specifications are subject to change without notice.

20

Page 25

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. All Interfaces

MS1690 Series Troubleshooting Guide Symptoms

Possible Causes

Solution

No power is being supplied to the scanner.

Check transformer, outlet and power strip. Make sure the cable is plugged into the scanner.

No power is being supplied to the scanner from the host.

Some host systems cannot supply enough current to power Focus. A power supply may be required.

The wrong communication cable has been used.

Check that the communication cable matches the unit type and scanner configuration.

There has been a scanner configuration failure.

Contact a Metrologic service representative, if the unit will not hold the saved configuration.

There has been a RAM or ROM failure.

Contact a Metrologic service representative, if the unit will not function.

Long Razz tone when exiting configuration mode

There was a failure to save the new configuration.

Re-try to configure the scanner. Contact a Metrologic Service Representative if the unit will not hold the saved configuration.

Long Razz tone

There is a scanning mechanism failure.

Contact a Metrologic service representative.

Short Razz tone in configuration mode

An invalid bar code has been scanned.

Scan a valid bar code or quit configuration mode.

No LEDs, beep or illumination

Long Razz tone on power up

21

Page 26

TROUBLESHOOTING GUIDE Symptoms

Possible Causes

Solution

The unit powers The beeper is up, but does not disabled and no tone beep when bar is selected. code is scanned.

Enable the beeper and select a tone.

The unit powers up, but does not scan and/or beep.

The bar code symbology trying to be scanned is not enabled.

UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128, Codabar and PDF are enabled by default. Verify that the type of bar code being read has been selected.

The unit powers up, but does not scan and/or beep.

The scanner is trying to scan a barcode that does not match the configured criteria.

Verify that the bar code being scanned falls into the configured criteria (i.e. character length lock or minimum bar code length settings).

The unit scans a bar code, but locks up after the first scan and the white LED stays on.

The scanner is configured to support some form of host handshaking but is not receiving the signal.

If the scanner is setup to support ACK/NAK, RTS/CTS, or XON/XOFF, verify that the host cable and host are supporting the handshaking properly.

The unit scans, but the data transmitted to the host is incorrect.

The scanner’s data format does not match the host system requirements.

Verify that the scanner’s data format matches that required by the host. Make sure that the scanner is connected to the proper host port.

22

Page 27

TROUBLESHOOTING GUIDE Symptoms

The unit beeps at some bar codes and NOT for others of the same bar code symbology.

The unit scans the bar code but there is no data.

The unit scans but the data is not correct.

Possible Causes

Solution

The print quality of the bar code is suspect.

Check print mode. The type of printer could be the problem. Change print settings (i.e. change to econo mode or high speed).

The aspect ratio of the bar code is out of tolerance.

Check print mode. The type of printer could be the problem. Change print settings (i.e. change to econo mode or high speed).

The bar code may have been printed incorrectly.

Check if it is a check digit/character/or border problem.

The scanner is not configured correctly for this type of bar code.

Check if check digits are set properly.

The minimum symbol length setting does not work with the bar code.

Check if the correct minimum symbol length is set.

The configuration is not set correctly.

Make sure the scanner is configured for the appropriate mode.

The configuration is not set correctly.

Make sure that the proper PC type AT, or PS2 is selected. Verify correct country code and data formatting are selected. Adjust inter-character delay symptom.

The scanner and host may not be configured for the same interface parameters.

Check that the scanner and the host are configured for the same interface parameters.

23

Page 28

TROUBLESHOOTING GUIDE Symptoms

Possible Causes

Solution

The unit is transmitting each character twice.

The configuration is not set correctly.

Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.

Alpha characters show as lower case.

The computer is in Caps Lock mode.

Enable Caps Lock detect setting of the scanner to detect if the PC is operating in Caps Lock.

Everything works except for a couple of characters.

These characters may not be supported by that country’s key look up table.

Try operating the scanner in Alt mode.

The com port at the host is not working or The unit powers not configured up OK and scans properly. OK but does not communicate properly with the The cable is not host. connected to the correct com port.

Characters are being dropped.

24

Inter-character delay needs to be added to the transmitted output.

Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS232” data.

Check to make sure that the cable is connected to the correct com port.

Add some inter-character delay to the transmitted output by using the Configuration Guides (MLPN 00-02544 and 00-02065).

Page 29

DESIGN SPECIFICATIONS MS1690 DESIGN SPECIFICATIONS OPERATIONAL Light Source:

LED 645 nm

Pulse Duration:

1 ms to 8 ms

Maximum Output of an Osram LED: Depth of Scan Field: Field of View: Minimum Bar Width: Infrared Activation:

Decode Capability:

Maximum 85 mA emits 3,120 mlm 0 mm – 230 mm (0" – 9") for 0.330 mm (13 mil) Bar Code at Default Setting 49 mm W x 19 mm H (1.9” W x 0.8” H) at 20 mm (0.8”) 264 mm x 106 mm (10.4” W x 4.2” H) at 280 mm (11.0”) 0.127 mm (5.0 mil) Long Range: 0 mm – 203 mm (0" – 8") from Window Short Range: 0 mm – 101 mm (0" – 4") from Window Autodiscriminates All Standard 1-D, RSS, PDF417, microPDF, MaxiCode, Data Matrix, QR Code, UCC, EAN Composites, Postals, Aztec (Image Transfer) – BMP, TIFF, or JPEG output

System Interfaces: Print Contrast: Number Characters Read: Beeper Operation: Indicators (LED) Default Settings:

PC Keyboard Wedge, RS232, IBM 468X/469X, Stand Alone Keyboard, USB (Low Speed and Full Speed) 20% Minimum Reflectance Difference Up to 80 Data Characters on 1D; 1850 Text Characters for PDF417 7 tones or no beep Blue

Unit Powered, Ready to Scan

White

Good Read

Yellow

In Stand

MECHANICAL Height: Width:

183 mm (7.2") Handle

- 30 mm (1.2")

Head

- 79 mm (3.1")

Depth:

111 mm (4.9")

Weight:

225 g (8.0 oz)

Termination: Cable:

10 pin modular RJ45 Standard 2.7 m (9') Coiled; Optional 2.1 m (7’) Straight

Specifications are subject to change without notice.

25

Page 30

DESIGN SPECIFICATIONS MS1690 DESIGN SPECIFICATIONS ELECTRICAL Input Voltage:

5.0VDC ± 0.25V Peak = 2 W (Typical)

Power:

Operating = 1.65 W (Typical) Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical)

Current:

Operation = 330 mA (Typical) Idle / Standby = 160 mA (Typical)

DC Transformer:

Class 2; 5.2VDC @ 650 mA

EMC:

FCC, ICES-003 & EN55022 Class A

Class 1 LED Product:

IEC 60825-1:1993+A1:1997+A2:2001

ENVIRONMENTAL Operating = 0°C to 40° (32° to 104°F) Temperature: Storage = -40°C to 60°C (-40°F to 140°F) Humidity: Light Levels: Shock: Contaminants: Ventilation:

5% to 95% Relative Humidity, Non-Condensing Up to 4842 Lux (450 Footcandles) Designed to withstand 1.8 m (6’) drops Sealed to resist airborne particulate contaminants None required

Specifications are subject to change without notice..

26