Page 31
APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. VERSION IDENTIFIER
SCANNER
MS1690 -
COMMUNICATION PROTOCOL(S)
11
IBM 468X/469X, RS232-TXD, RXD, RTS, CTS
14
RS232 (TX, RX, RTS, CTS, DTR)
38
Low Speed USB
40
Full-speed USB
47
Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive
The MS1690-47 with a built-in PC Keyboard Wedge Interface is designed for Keyboard emulation use only. Many RS232 configurable functions available in other Metrologic scanners are also available as keyboard wedge functions. The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • •
**AT (includes IBM® PS2 models 50, 55, 60, 80) IBM PS2 (includes models 30, 70, 8556) Keyboard Country Type
• • • **
**USA Belgium French
• • •
German Italian Japanese
• • •
Spanish Swiss United Kingdom
For additional information on the MS 1690’s default settings refer to pages 28-31. For information on how to change the default settings, refer to help files in MetroSet2 or the MetoSelect Single-Line Configuration Guide (MLPN 00-02544).
27
Page 32
DEFAULT SETTINGS – COMMUNICATION PARAMETERS Many functions of the scanner can be “configured” – that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages. If an asterisk is not in the default column then the default setting is OFF or DISABLED. Every interface does not support every parameter. If the interface supports a parameter listed in the charts on the following pages, a check mark (9) will appear. PARAMETER
DEFAULT
RS232
IBM 46XX
KBW
USB
Multi-Try Trigger Out-of-Stand
*
9
9
9
9
Presentation Mode In-Stand
*
9
9
9
9
Continuous Trigger
9
9
9
9
Single Trigger
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
Aiming in Trigger and Continuous Modes
*
Aiming in Presentation Mode Long-Range In-Stand
*
Short-Range In-Stand Long-Range Out-of-Stand
*
Short-Range Out-of-Stand UPC/EAN
*
9
9
9
9
Code 128
*
9
9
9
9
Code 93
*
9
9
9
9
Codabar
*
9
9
9
9
Interleaved 2 of 5 (ITF)
*
9
9
9
9
MOD 10 check on ITF
9
9
9
9
Code 11
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
Data Matrix
9
9
9
9
QR Code
9
9
9
9
Code 39
*
Full ASCII Code 39 PDF
28
*
Page 33
DEFAULT SETTINGS – COMMUNICATION PARAMETERS PARAMETER
RS232
IBM 46XX
KBW
USB
Maxicode
9
9
9
9
Aztec
9
9
9
9
Postals
9
9
9
9
Mod 43 Check on Code 39
9
9
9
9
MSI-Plessy 10/10 Check Digit
9
9
9
9
9
9
9
9
9
9
9
9
MSI-Plessy Mod 10 Check Digit
DEFAULT
*
Paraf Support ITF ITF Symbol Lengths
Variable
9
9
9
9
Symbol Length Lock
None
9
9
9
9
Beeper tone
Normal
9
9
9
9
Beep/transmit sequence
Before transmit
9
9
9
9
Communication timeout
None
9
9
9
9
Razzberry tone on timeout
9
9
9
9
Three beeps on timeout
9
9
9
9
9
9
9
9
Same symbol rescan timeout configurable in 50 msec steps (maximum of 6.35 sec.)
9
9
9
9
No Same symbol timeout
9
9
9
9
Infinite Same symbol timeout
9
9
9
9
1 msecs 10 msecs in KBW
9
9
9
9
Number of scan buffers (maximum)
8
9
9
9
9
Transmit UPC-A check digit
*
9
9
9
9
Transmit UPC-E check digit
9
9
9
9
Expand UPC-E
9
9
9
9
Convert UPC-A to EAN-13
9
9
9
9
Same symbol rescan timeout: 1000 msecs
Inter-character delay configurable in 1 msec steps (maximum of 255 msecs)
*
29
Page 34
DEFAULT SETTINGS – COMMUNICATION PARAMETERS PARAMETER
DEFAULT
Transmit lead zero on UPC-E
RS232
IBM 46XX
KBW
USB
9
9
9
9
Transmit UPC-A number system
*
9
9
9
9
Transmit UPC-A Manufacturer ID#
*
9
9
9
9
Transmit UPC-A Item ID#
*
9
9
9
9
Transmit Codabar Start/Stop Characters
9
9
9
9
CLSI Editing (Enable)
9
9
9
9
Transmit Mod 43 Check digit on Code 39
9
9
9
9
Transmit Mod 10/ITF
9
9
9
9
Transmit MSI-Plessy
9
9
9
9
9
Parity
No
9
Baud Rate
9600
9
8 Data Bits
*
9 9
7 Data Bits Stop Bits
9
1
9
Transmit Sanyo ID Characters
9
9
Nixdorf ID
9
9
LRC Enabled
9
9
UPC Prefix
9
9
UPC Suffix
9
9
Carriage Return
*
9
9
Line Feed-Disabled by default in KBW
*
9
9
Tab Prefix
9
9
Tab Suffix
9
9
“DE” Disable Command
9
Enable Command
9
DTR Handshaking support
9
RTS/CTS Handshaking
9
Character RTS/CTS Message RTS/CTS
30
*
9 9
Page 35
DEFAULT SETTINGS – COMMUNICATION PARAMETERS PARAMETER
DEFAULT
RS232
IBM 46XX
KBW
USB
XON/XOFF Handshaking
9
ACK/NAK
9
Two Digit Supplements
9
9
9
9
Five Digit Supplements
9
9
9
9
Bookland
9
9
9
9
977 (2 digit) Supplemental Requirement
9
9
9
9
Supplements are not Required
*
9
9
9
9
Two Digit Redundancy
*
9
9
9
9
Five digit Redundancy
9
9
9
9
Coupon Code 128
9
9
9
9
† Configurable Code Lengths
7 avail
9
9
9
9
† Code Selects with configurable Code Length Locks
3 avail
9
9
9
9
Configurable Prefix characters
10 avail
9
9
Suffix characters
10 avail
9
9
Prefixes for Individual Code types
9
9
Editing
9
9
9
9
Function/Control Key Support
*
9
9
9
9
Omnidirectional Scanning
*
9
9
9
9
Linear Only Scanning
9
9
9
9
Linear 1D / Omni 2D
9
9
9
9
† These options are mutually exclusive. One can not be used in conjunction with the other.
31
Page 36
CONFIGURATION MODES The MS1690 Focus Series has three modes of configuration. •
Bar Codes The MS1690 can be configured by scanning the bar codes included in the Metrologic Single-Line Configuration Guide (MLPN 00-02544). This manual can be downloaded for FREE from Metrologic’s website (www.metrologic.com).
•
MetroSet2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options. This program can be downloaded for FREE from Metrologic’ website (www.metrologic.com) or set-up disks can be ordered by calling 1-800-ID-METRO.
•
Serial Programming This mode of configuration is ideal for OEM applications. This mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single-Line Configuration Guide (MLPN 00-02544).
32
Page 37
UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash- based scanners. This program allows the user of a Metrologic scanner to quickly upgrade to a new or custom version of firmware. It requires the use of a personal computer running Windows 95 or greater and the use of a serial port. The user merely connects the scanner to a serial port on the PC, launches the MetroSet2 program, and blasts off to new software upgrades. Each MS1690, regardless of the version number or communication protocol, can be upgraded. In other words, all RS232 (-14), keyboard wedge (-47), IBM 468X/469X (-11), low speed USB (-38), and full speed USB (-40) units can be upgraded. To upgrade all units, a power supply and PowerLink cable (MLPN 54-54014) are required. RS232 units can be upgraded using the standard PowerLink cable (MLPN 53-53xxx-3). The program guides the user with its simplistic one click approach. The user must first select the file. Once the file is selected and verified, the scanner is ready to be upgraded. Press the “Flash Scanner” button to upgrade the scanner. The unit will go into a “flash mode” – the blue and white LEDs will be flashing alternately. The user can follow the progress of the upgrade by watching the screen for details. When the upgrade is complete, the scanner will reset itself. If a razz/beep occurs, the scanner did not upgrade properly. Contact a Metrologic service representative for additional assistance.
33
Page 38
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections MS1690-14, RS232 The MS1690 scanner interfaces terminate to a 10-pin, RJ45 Female Socket. The serial # label indicates the interface enabled when the scanner is shipped from the factory.
Pin
Function
1 2 3 4 5 6 7 8 9 10
Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input DTR Input Reserved Reserved +5VDC Shield Ground MS1690-47, Keyboard Wedge & Stand-Alone Keyboard
Pin 1 2 3 4 5 6 7 8 9 10
Function Ground RS232 Transmit Output RS232 Receive Input PC Data PC Clock KB Clock PC +5V KB Data +5VDC Shield Ground MS1690-11, IBM 468X/469X
Figure 18.
34
Pin
Function
1 2 3 4 5 6 7 8 9 10
Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input Reserved IBM B-Transmit IBM A+ Receive +5VDC Shield Ground
Page 39
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections MS1690-38, Low Speed USB Pin 1 2 3 4 5 6 7 8 9 10
Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input USB D+ V USB USB D+5VDC Shield Ground
MS1690-40, Full Speed USB Pin 1 2 3 4 5 6 7 8 9 10
Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input USB D+ V USB USB D+5VDC Shield Ground
Figure 19.
35
Page 40
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000-3 Coiled
Pin
Function
1
Shield Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4
DTR Input/Light Pen Source
5
Power/Signal Ground
6
Reserved
7
CTS Input
8
RTS Output
9
+5VDC
9
5
6
1
9-Pin D-Type Connector
Stand Alone Keyboard PowerLink Cable 53-53020-3 Pin 1 2 3 4 5 6
Function PC Data NC Power Ground +5VDC PC Power to KB PC Clock NC
1
2 4
3 6 5
6-Pin Male Mini-DIN Connector
USB Power/Communication Cable 53-53213-N-3, 53-53214-N-3 or 53-53235-N-3
Pin 1
Function PC +5V/V_USB
2
D-
3
D+
4
Ground
Shield Shield
36
USB Type A Locking with Power
USB Non-Locking