Page 11
INSTALLING THE SCANNER TO THE HOST SYSTEM RS232 MS1690-14 1.
Turn off the host device.
2.
Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made.
3.
Connect the 9-pin D-type connector of the communication cable to the proper COM port of the host device.
4.
Plug the power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible. Figure 6.
5.
Connect AC power to the transformer.
6.
Focus will start to initialize. All LEDs (yellow, white, and blue) will light for approximately 2 seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep 3 times indicating that the scanner is ready for use.
7.
Turn on the host device. Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950. To maintain compliance with standard CSA-C22.2 No. 60950-00/UL 60950 and norm EN/IEC 60950, the power source should meet applicable performance requirements for a limited power source.
7
Page 12
INSTALLING THE SCANNER TO THE HOST SYSTEM Keyboard Wedge MS1690-47 1.
Turn off the host device.
2.
Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made.
3.
Disconnect the keyboard from the host device.
4.
Connect the “Y” ends of the communication cable to the keyboard and keyboard port on the host device. If necessary use the male/female adapter cable supplied with the scanner for proper connections.
5.
Plug the external power supply (required) into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.
Figure 7.
6.
Connect AC power to the transformer.
7.
Focus will start to initialize. All LEDs (yellow, white, and blue) will light for approximately 2 seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep 3 times indicating that the scanner is ready for use.
8.
Turn on the host device. Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950. To maintain compliance with standard CSA-C22.2 No. 60950-00/UL 60950 and norm EN/IEC 60950, the power source should meet applicable performance requirements for a limited power source.
8
Page 13
INSTALLING THE SCANNER TO THE HOST SYSTEM Stand Alone Keyboard MS1690-47 1.
Turn off the host device.
2.
Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made.
3.
Plug the other end of the communication cable into the host’s keyboard port.
4.
Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible. Figure 8.
5.
Connect AC power to the transformer.
6.
Focus will start to initialize. All LEDs (yellow, white, and blue) will light for approximately 2 seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep 3 times indicating that the scanner is ready for use.
7.
Turn on the host device. Plugging the scanner into a port on the host device does not guarantee that scanned information will be communicated properly to the host device. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950. To maintain compliance with standard CSA-C22.2 No. 60950-00/UL 60950 and norm EN/IEC 60950, the power source should meet applicable performance requirements for a limited power source.
9
Page 14
INSTALLING THE SCANNER TO THE HOST SYSTEM IBM MS1690-11 1.
Turn off the host device.
2.
Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made.
3.
Connect the other end of the MVC cable to the host device.
4.
Turn on the host device.
5.
Focus will start to initialize. All LEDs (yellow, white, and blue) will light for approximately 2 seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep 3 times indicating that the scanner is ready for use. Figure 9.
Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol.
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950. To maintain compliance with standard CSA-C22.2 No. 60950-00/UL 60950 and norm EN/IEC 60950, the power source should meet applicable performance requirements for a limited power source.
10
Page 15
INSTALLING THE SCANNER TO THE HOST SYSTEM Integrated USB: Full Speed MS1690-40 Low Speed MS1690-38 1.
Turn off the host device.
2.
Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made.
3.
Plug the USB type A end of the USB cable into the host’s USB port.
4.
Turn on the host device.
5.
Focus will start to initialize. All LEDs (yellow, white, and blue) will light for approximately 2 seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep 3 times indicating that the scanner is ready for use.
Figure 10.
As a default, the MS1690-38 leaves the factory with USB Keyboard Emulation Mode eabled. For information on configuring the MS1690-38 for USB Serial Emulation Mode, please refer to the USB section of the MetroSelect Single-Line Configuration Guide (MLPN 00-02544). Plugging the scanner into a port on the host device does not guarantee that scanned information will be communicated properly to the host device. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950. To maintain compliance with standard CSA-C22.2 No. 60950-00/UL 60950 and norm EN/IEC 60950, the power source should meet applicable performance requirements for a limited power source.
11
Page 16
STAND KITS STAND COMPONENTS, MLPN 46-00147
Figure 11. Stand Components
12
Item
Description
Qty.
a.
Stand Base
Qty. 1 b.
Flexible Shaft
Qty. 1 c.
Flexible Shaft Cover
Qty. 1 d.
Scanner Cradle
Qty. 1 e.
¼" – 20 x 3/8" Flat Head Phillips, 82° Undercut
Qty. 2 f.
#8 Round Head Wood Screw
Qty. 2
Page 17
STAND KITS HARD MOUNTING THE STAND (OPTIONAL) Metrologic provides two #8 wood screws for securing the stand base to the counter top. The following figure provides the pilot hole dimensions for securing the stand base.
Figure 12. Stand Base Hole Pattern (Not to Scale)
13
Page 18
STAND KITS
ASSEMBLING THE STAND
14 if < - %"-20x%" Flat Head | Phillips 82° Undercut
~<t - Scanner Cradle
Orient the scanner cradle so that the flexible shaft's flat surface is facing the body of the scanner cradle.
~<t - Flexible Shaft Cover
Flat Surface
~<t - Flexible Shaft
Position the flexible shaft so that the flat surface on the end is flush against the tab on the stand base.
[ Stand Base i i i T 1 |
E < - %'-20x%' Flat Head Phillips 82° Undercut
Figure 13. Assembling the Stand
Page 19
SCANNER OPERATION TWO DEFAULT MODES OF OPERATION* CodeGate, Out of Stand 1.
The IR detects an object in the IR activation range and automatically turns on linear illumination.
2.
Aim the scanner’s line of light over the bar code.
3.
Pull the trigger to initiate scanning. The scanner’s light output will start to flash as it attempts to scan the bar code. If the trigger is released the scanner will stop trying to scan.
4.
When scanner successfully reads the bar code it will beep once, the white LED will flash and the decoded data will be transmitted to the host.
Presentation, In-Stand
Figure 14. CodeGate, Out-of-Stand
1.
The IR detects an object in the IR activation range and the scanner’s light output automatically starts to flash as it attempts to scan the bar code.
2.
The scanner continuously attempts to scan the bar code until either it succeeds or the bar code is removed from the scanner’s field of view.
3.
When scanner successfully reads the bar code it will beep once, the white LED will flash and the decoded data will be transmitted to the host.
* For additional configurable modes of operation, please refer to the MS1690 Focus Supplemental Configuration Guide (MLPN 00-02065).
15
Page 20
SCANNER OPERATION Audible Indicators When the Focus is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect Single-Line Configuration Guide, MLPN 00-02544 or MetroSet2’s help files. One Beep When the scanner successfully reads a bar code it will beep once and the white LED will turn on indicating data is being transmitted. If the scanner does not beep once and the white light does not turn on, then the bar code has not been successfully read. Short Razzberry Tone This tone is a failure indicator (see Failure Modes on page 18). Long Razzberry Tone This tone is a failure indicator (see Failure Modes on page 18). Three Beeps - At Power Up When Focus first receives power it will start an initialization sequence. All LEDs (yellow, white, and blue) will light for approximately 2 seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep 3 times indicating that the scanner is ready for use. Three Beeps - Configuration Mode When entering configuration mode, the white LED will flash while the scanner simultaneously beeps three times. The white and blue LEDs will continue to flash while in this mode. Upon exiting configuration mode, the scanner will beep three times, and the LEDs will stop flashing. When configured, 3 beeps can also indicate a communications timeout during normal scanning mode. When using single-code-configuring, the scanner will beep three times: a normal tone followed by a short pause, a high tone and then a low tone. This indicates that the single configuration bar code has successfully configured the scanner.
16