The text of a manual · part 1 of 6
MS1690 Focus Area Imaging Bar Code Scanner Installation and User's Guide: MS1690 Focus, pages 1 to 10
Pages 1 to 10 of 52, from MS1690 Focus Area Imaging Bar Code Scanner Installation and User's Guide
The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS1690
Page 1
00-02098_Cover_Quark_March_2005.qxd
3/11/2005
9:31 AM
Page 1
METROLOGIC INSTRUMENTS, INC.
MS1690 Focus Area Imaging Bar Code Scanner Installation and User’s Guide ™
Page 2
Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.
Page 3
TABLE OF CONTENTS Introduction ............................................................................................................1 Scanner and Accessories ..................................................................................2 Scanner Components ........................................................................................4 The PowerLink Cable ........................................................................................5 Labels ................................................................................................................6 Maintenance ......................................................................................................6 Installing the Scanner to the Host System RS232 MS1690-14 ............................................................................................7 Keyboard Wedge MS1690-47 ...........................................................................8 Stand Alone Keyboard MS1690-47 ...................................................................9 IBM MS1690-11...............................................................................................10 Full Speed USB MS1690-40 (Integrated) ........................................................11 Low Speed USB MS1690-38 (Integrated) .......................................................11 Stand Kits Stand Components, MLPN 46-00147..............................................................12 Hard Mounting the Stand.................................................................................13 Assembling the Stand......................................................................................14 Scanner Operation Two Default Modes of Operation .....................................................................15 Audible Indicators ............................................................................................16 Visual Indicators ..............................................................................................17 Failure Modes ..................................................................................................18 Depth of Field by Minimum Bar Code Element Width .....................................19 IR Activation Range .........................................................................................20 Troubleshooting Guide ........................................................................................21 Design Specifications ..........................................................................................25 Applications and Protocols ..................................................................................27 Default Settings – Communication Parameters...................................................28 Configuration Modes............................................................................................32 Upgrading the Flash ROM Firmware ...................................................................33 ii
Page 4
TABLE OF CONTENTS Scanner and Cable Terminations Scanner Pinout Connections .......................................................................... 34 Cable Connector Configurations .................................................................... 36 Limited Warranty ................................................................................................ 38 Product Safety Notices ........................................................................................................... 39 Cautions ......................................................................................................... 40 Patents ............................................................................................................... 41 Index .................................................................................................................. 42 Contact Information and Office Locations........................................................... 45 iii
Page 5
INTRODUCTION The MS1690 Focus is a high performance hand-held area imaging bar code scanner that utilizes high-resolution CMOS imaging sensors for superior image quality. Focus utilized Omniplanar, Inc.’s Swiftdecoder™ software, for reliable decoding of both 1D and 2D bar code symbologies. Sharp images can be captured and transmitted in a variety of outputs including: .jpg, .bmp, and .tiff. Omnidirectional scanning capabilities and an extended depth of field width provides aggressive scanning of all standard 1D, RSS, PDF417, microPDF, Composite, Matrix and Postal Codes symbology types. Firmware updates are easily loaded via Flash ROM. Focus provides an extended depth of field width and a built in object detection sensor (IR) that instantly turns on the scanner when an object is presented within the scanner’s field of view. Automatic in-stand detection switches the scanner to a “presentation” mode for convenient in-stand scanning. Focus incorporates ® Metrologic’s patented CodeGate technology for accurate menu style scanning and on command data transmission.
Focus™
Interface
MS1690 – 11
IBM 468X/469X, RS232-TXD, RXD, RTS, CTS
MS1690 – 14
RS232 (TX, RX, RTS, CTS, DTR)
MS1690 – 38
Low Speed USB
MS1690 – 40
Full Speed USB
MS1690 – 47
Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive
1
Page 6
INTRODUCTION Scanner and Accessories BASIC KIT Part #
Description
MS1690
Focus Area Imaging Bar Code Scanner
00-02544
MetroSelect® Single-Line Configuration Guide*
00-02065
Supplemental Configuration Guide*
00-02098
MS1690 Focus Area Imaging Bar Code Scanner Installation and User’s Guide* * Available on the Metrologic website - www.metrologic.com
OPTIONAL ACCESSORIES Part #
Description
AC to DC Power Transformer - Regulated 5.2VDC @ 650 mA output. 45-45593
120V United States
45-45591
220V-240V Continental European
45-45592
220V-240V United Kingdom
46-46803
220V-240V Australia
46-46983
220V-240V China
53-53000-3
RS232 PowerLink Cable with Built in Power Jack 2.7 m (9 ft.) coiled cord, long strain relief, black
53-53002-3
Keyboard Wedge PowerLink Cable with Adapter Cable 2.7 m (9 ft.) coiled cord, long strain relief, black
53-53020-3
Stand Alone Keyboard PowerLink Cable 2.7 m (9 ft.) coiled cord, long strain relief, black
Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.
2
Page 7
INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part # 53-53213x-N-3
Description USB Power/Communication Cable, 2.7 m (9 ft.) coiled cord, long strain relief, black USB Power/Communication Cable, 4.5 m (15 ft.) coiled cord, long strain relief, black
53-53214x-N-3 This cable is for use with full speed USB (-40) interface only. 53-53235x-N-3
Low Speed USB Non-Locking Communication Cable 2.7 m (9 ft.) coiled cord, long strain relief, black
MVC-2MPC-IB9
Metrologic Voltage Converter (MVC) Cable* ±12VDC to +5.2VDC
* Contact a Metrologic customer service representative for additional information on the MVC cable series and the host connections available. 00-02001
MS1690 Focus Stand (46-00147) Installation Guide
46-00147
Modular Presentation Stand
Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.
3
Page 8
INTRODUCTION Scanner Components
Figure 1. Scanner Components
Item Description
4
1
Yellow LED
See Visual Indicators (on page 17)
2
White LED
See Visual Indicators (on page 17)
3
Blue LED
See Visual Indicators (on page 17)
4
Speaker
See Audible Indicators (on page 16)
5
Trigger
6
Red Window
LED Aperture
7
Cable Release
See The PowerLink Cable (on page 5)
8
Cable Connection
10-pin RJ45, Female Socket, See Scanner Pinout Connections (on page 34)
Page 9
INTRODUCTION THE POWERLINK CABLE CONNECTING Important: If the PowerLink cable is not fully ‘latched’ the unit can power intermittently.
Figure 2.
Figure 3.
DISCONNECTING Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disconnected from the PowerLink cable.
Figure 4. Releasing the PowerLink Cable
1.
Locate the small ‘pin-hole’ on the handle of the unit near the cable.
2.
Bend an ordinary paperclip into the shape shown above.
3.
Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’.
4.
You will here a faint ‘click’. Pull gently on the strain-relief of the PowerLink cable to remove the cable from the unit.
5
Page 10
INTRODUCTION Labels Each scanner has a label located on the underside of the head. This label provides the unit’s model number, date of manufacture, serial number, CE and caution information. The following figure gives an example of the label and its location.
Figure 5. Label Samples and Location
Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning.
6
1.
Spray glass cleaner onto lint free, non-abrasive cleaning cloth.
2.
Gently wipe the scanner window.