Page 21
DEPTH OF FIELD AND SCAN PATTERN CHARACTERISTICS IS8800 Depth of Field and Scan Pattern
The depth of field area defined is based conservatively on a 0.33 mm/0.013” bar code width. Actual scan areas will vary by label size and application.
17
Page 22
MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1.
Spray optical quality cleaning fluid onto lint free, nonabrasive cleaning cloth.
2.
Gently wipe the output window.
Do not use solvents like alchohol or acetone. These materials can damage the window.
18
Page 23
TROUBLESHOOTING GUIDE PROBLEM No LEDs
POSSIBLE CAUSE(S)
ACTION NEEDED
No Power Check the power supply and outlet.
No Scan Pattern
No Power
Alternating Red and Green LEDs flash with a razz tone.
Motor Failure
Contact a Metrologic service representative.
The communication cable is not connected to the COM port.
Check the communication cable connection at the host and scanner.
The communication cable is damaged.
Replace the communication cable.
Scanner configuration settings have been lost.
Reconfigure using MetroSet 2.
The host is receiving data but the data does not look correct.
There is an interface format incompatibility.
Check that the unit and the host are configured for the same interface format.
Unit has shows a reduction in scan performance.
Scan window dirty
Clean the unit’s window (refer to the maintenance section).
The unit scans but does not communicate with the host.
19
Page 24
APPENDIX A Design Specifications IS8800
IS8500
IS8400
IS8300
5
5
3
5
Optical Number of VLD Scan pattern
Omni
Omni
Omni
Omni
Scan lines per second
5,600
5,600
3,360
5,250
Focal planes
4
4
4
5
Scan lines per focal plane
20
20
12
15
Total scan lines Minimum bar width
80
80
48
75
0.30 mm/0.012”
0.25 mm/0.010”
0.25 mm/0.010”
0.20 mm/0.008”
Scan Area (Small Bar Widths) Bar width
0.33 mm/0.013”
0.33 mm/0.013”
0.33 mm/0.013”
0.25 mm/0.010”
Near scan
790 mm/31”
910 mm/36”
910 mm/36”
510 mm/20”
Far scan
1600 mm/63”
1630 mm/64”
1630 mm/64”
970 mm/38”
Depth of field
810 mm/32”
720 mm/28”
720 mm/28”
460 mm/18”
Width
460 mm/18”
560 mm/22”
560 mm/22”
310 mm/12”
1.5 mps/300 fpm
1.5 mps/300 fpm
1.5 mps/300 fpm
1.5 mps/300 fpm
Conveyor speed Mechanical Length
349 mm/13.75”
349 mm/13.75”
349 mm/13.75”
254 mm/10”
Width
336 mm/13.25”
336 mm/13.25”
336 mm/13.25”
380 mm/11.1”
Height
177 mm/7.0”
177 mm/7.0”
177 mm/7.0”
141 mm/5.5”
Weight
11.0 kg/25lb
11.0 kg/25lb
11.0 kg/25lb
9.0 kg/20lb
Case
NEMA 12
NEMA 12
NEMA 12
NEMA 12
Yes
Yes
Yes
Yes
Serial: RS-232C
RS232C
RS232C
RS232C
RS232C
Serial: Point-to-Point RS422
RS422
RS422
RS422
RS422
Light Pen Emulation
Light Pen
Light Pen
Light Pen
Light Pen
Handheld Scanner Port
Option
Option
Option
Option
Master slave
Yes
Yes
Yes
Yes
Industrial Controller/Triac
Yes
Yes
Yes
Yes
Mounts any orientation Interfaces
20
Page 25
APPENDIX A (CONTINUED) Design Specifications IS8800
IS8500
IS8400
IS8300
Input Voltage
12 VDC
12 VDC
12 VDC
12 VDC
Starting Power
69 watts
69 watts
53 watts
53 watts
Operating power
43 watts
43 watts
34 watts
34 watts
EMC: FCC, ICES-003 & EN 55022
Class A
Class A
Class A
Class A
658 nm ± 5 nm
658 nm ± 5 nm
658 nm ± 5 nm
658 nm ± 5 nm
Laser power (peak)
7.7 mW
7.7 mW
7.7 mW
7.7 mW
Laser power (average)
<1 mW
<1 mW
<1 mW
<1 mW
Laser class: CDRH
Class II
Class II
Class II
Class II
Laser class: EN
Class 2
Class 2
Class 2
Class 2
Electrical
Laser Wavelength
Environmental Operating Temperature
0°C to 40°C (32°F to 104°F)
Storage Temperature
-40°C to 60°C (-40°F to 140°F)
Humidity Light Levels Shock Contaminants Ventilation
5% to 95% relative humidity, non-condensing Up to 297.4 lux (3200 foot candles) – works in direct sunlight 100 g for 1 ms Protects against dust, falling dirt, and dripping non-corrosive liquid None required Actual scan areas will vary by label size and application. Specifications subject to change without notice.
21
Page 26
APPENDIX B Default Settings Many functions of the scanner can be configured, or enabled/disabled. The factory programs the scanner to a set of default parameters. These defaults are marked with an asterisk (*) in the default column on the following pages. Unmarked parameters show the unavailability for that protocol. To speak with the host system properly, the scanner must be configured to match the systems individual requirements. Not all functions support all communication protocols. If the protocol supports a function, a check mark appears on the chart. PARAMETER
DEFAULT
RS-232
RS-422
*
9
9
LIGHT PEN
INTERFACE FORMAT RS-232 (RS-422)
9
Light Pen No Comm
Test Mode Only
CODE TYPES All UPC/EAN
*
9
9
9
Code 39
*
9
9
9
Full ASCII Code 39
9
9
9
MOD 43 Check on Code 39
9
9
9
Code 93
*
9
9
9
Code 128
*
9
9
9
Codabar
*
9
9
9
Interleaved 2 of 5 (ITF)
*
9
9
9
MOD 10 Check on ITF
9
9
9
Do Not Scan EAN-8
9
9
9
Do Not Scan EAN-13
9
9
9
Do Not Scan UPC-E
9
9
9
Do Not Scan UPC-A
9
9
9
Paraf
9
9
9
UCC Supplemental Codes
Special firmware required
2 Digits Supps
9
9
5 Digit Supps
9
9
9 9
977 (2 Digit Supps)
9
9
9
Bookland
9
9
9
Redundancy 2 Digits
9
9
9
Redundancy 5 digits
9
9
9
Require Supps
9
9
9
9
9
9
100 msec to find Supps
22
*
Page 27
APPENDIX B (CONTINUED) RS-232
RS-422
LIGHT PEN
200 msec to find Supps
9
9
9
Code 128 Coupon Option
9
9
9
Code 128 Coupon Conversion
9
9
9
PARAMETER
DEFAULT
378/379 lock on supplement
9
9
9
Remote supplement required
9
9
9
9
9
9
9
9
9
Faster Beep/Same Tone
9
9
9
Lost Communication Timeout 3 beeps on timeout razz beep on timeout 5 retrys before timeout
9
9
9
Support 'D/E' disable/enable commands
9
9
Support 'F/L' laser off/on commands
9
9
Enable MECCA
9
9
9
9
9
9
9
9
MISCELLANEOUS Beep after transmitting Beep before transmitting
One Compare Buffer
*
*
Two Compare Buffers
9
Four Compare Buffers
9
9
9
Eight Compare Buffers
9
9
9
Scan Count
9
9
9
Reverse LED convention
9
9
9
Support multiple beep 'B'/razz 'Z' commands
9
9
Support host BEL/CAN (cancel) command
9
9
Enter program mode only after power up
9
9
Enable status reporting
9
9
Number of good scans required (1-8)
1
Special code select
9
9
9
9
9
9
9
9
9
9
Loud Volume
9
9
9
Support 'M/O' motor off/on commands
9
9
Normal volume
*
TRIAC/LINE SENSOR Support Line Sensor
9
9
9
Support Line Sensor Alarm
9
9
9
Transmit 'No Read' message on sensor timeout
9
9
9
Scans per Sensor Activation (1-5)
9
9
9
Scan Duration (sec.)
9
9
9
Support Triac
9
9
9
Triac Controlled by the Host (DC2/DC4)
9
9
Triac Normally On
9
9
9
Enable Read and Match Mode
9
9
9
23
Page 28
APPENDIX B (CONTINUED) RS-232
RS-422
LIGHT PEN
Fire triac if good read/match
9
9
9
Fire triac if bad match
9
9
9
Fire triac if no read
9
9
9
PARAMETER
DEFAULT
Triac Duration (sec.)
9
9
9
Delay Time before firing (sec.)
9
9
9
Enable programmable 'No Read' message
9
9
9
Retain same symbol timers along with line sensor
9
9
9
Supports dual line sensor inputs
9
9
9
Buffer scans until line sensor cycle completes
9
9
9
Save read and match bar code if power down
9
9
9
9
9
9
9
9
9
9600
9
9 9
SCAN RANGE Close, Extended and Normal
Extended
RESERVE CODES Reserve Code 1-99 RS232 FORMAT BAUD 300-38,400 DATA FORMAT Space
9
7 Data Bits/8 Data Bits
7 Data Bits
9
9
1 Stop bit/2 Stop bits
2 Stop bits
9
9
9
9
Odd, Space, Even, Mark, None Parity
OPTIONS Ack/Nak handshaking CR
*
9
9
LF
*
9
9
DTR support
9
9
Nixdorf ID
9
9
RTS/CTS handshaking
9
9
RTS/CTS (character)
9
9
RTS/CTS (message)
9
9
ETX suffix
9
9
STX prefix
9
9
Tab prefix
9
9
Tab suffix
9
9
UPC prefix
9
9
UPC suffix
9
9
Schlumberger/Shell format
9
9
Transmit AIM ID Chr
9
9
24
Page 29
APPENDIX B (CONTINUED) PARAMETER
RS-232
RS-422
Transmit SANYO ID Chr
9
9
SNI Beetle Mode
9
9
9
9
French PC Term
DEFAULT not currently supported
Xon/Xoff handshaking
9
9
Programmable prefix identifiers
9
9
9
9
LIGHT PEN
Xmit (dec) as 1st prefix identifier Xmit (dec) as 2nd prefix identifier Programmable suffix identifiers Xmit (dec) as 1st suffix identifier Xmit (dec) as 2nd suffix identifier LIGHT PEN FORMAT POLL SRC No/Yes
No
9
Spaces/as scanned
9
HI/OUTPUT Bars/Code 39, Spaces/Code 39, Spaces/Code 39, Bars/as scanned, Spaces/as scanned OPTIONS Extra Transition before Bar Code
9
50x element border
9 9
10x narrow element border 1.0 ms narrow element
9
*
.50 ms narrow element
9
.30 ms narrow element
9
.15 ms narrow element
9
FORMATTING - UPC Convert EAN-8 to EAN-13
9
Convert UPC-A to EAN-13
9
9
Expand UPC-E
9
9
Transmit lead zero on UPC-E Transmit UPC-A check digit
*
Transmit UPC-A Number System
*
Transmit UPC-E check digit
9
9
9
9
9
9
9
9
9
Transmit EAN-13 check digit
*
9
9
Transmit EAN-8 check digit
*
9
9
CLSI editing
9
9
Transmit Codabar Start/Stop Characters
9
9
FORMATTING - NONUPC
25
Page 30
APPENDIX B (CONTINUED) PARAMETER
DEFAULT
RS-232
RS-422
Transmit Code 39 Start/Stop Characters
9
9
Transmit ITF Mod 10 check digit
9
9
Transmit Code 39 Mod 43 check digit
9
9
9
9
LIGHT PEN
SYMBOL LENGTH ITF(variable length-50 char)
14 char lock
9
Min 1-50
4
9
9
9
Lock 0-50
0
9
9
9
Normal
9
9
9
Flash
9
9
9
.5 secs
9
9
9
1 msec.
9
9
BEEPER TONE Normal, Alt1, Alt 2, Alt3, Alt4, None LED Flash/None Same Symbol Time Out .1, .2, .5, 1.25, 2.00secs, infinite TRANSMISSION DELAY - Inter character 1,5,20 msec, none
26