The text of a manual · part 1 of 4
HoloTrak IS8000 Series Holographic Scanners Installation and User's Guide, pages 1 to 10
Pages 1 to 10 of 40
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic IS8300, Metrologic IS8400, Metrologic IS8500 and Symbol IS8500
Page 1
@ Metrologic’
METROLOGIC INSTRUMENTS, INC. HoloTrak® IS8000 Series
Holographic Scanners Installation and User’s Guide
Page 2
Page 3
LOCATIONS Corporate Headquarters North America
Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683
Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com
European Headquarters Germany, Middle East and Africa
Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany
Tel: +49 89 89019 0 Fax: +49 89 89019 200 Email: info@europe.metrologic.com Germany Email: info@de.metrologic.com
Spain
Metrologic Eria lbérica SL Julián Camarillo 29, D-1 Edificio Diapasón 28037 Madrid
Tel: +34 913 272 400 Fax: +34 913 273 829 Email: info@es.metrologic.com
Italy
Metrologic Instruments Italia srl Via Emilia 70 40064 Ozzano dell’Emilia (BO)
Tel: +39 0 51 6511978 Fax: +39 0 51 6521337 Email: info@it.metrologic.com
France
Metrologic Eria France SA 69 Rue de la Belle Etoile ZI Paris Nord II, BP 50057 95947 – ROISSY CDG CEDEX
Tel: +33 (0) 1 48.63.78.78 Fax: +33 (0) 1 48.63.24.94 Email: info@fr.metrologic.com
United Kingdom
Metrologic Instruments UK Limited 58 Tempus Business Centre Kingsclere Road, Basingstoke Hampshire RG21 6XG
Tel: +44 (0) 1256 365900 Fax: +44 (0) 1256 365955 Email: info@uk.metrologic.com
Singapore
Metrologic Asia (Pte) Ltd No. 8 Kaki Bukit Place 4th Floor Singapore 416186
Tel: 65-6842-7155 Fax: 65-6842-7166 Email: info@sg.metrologic.com
China
Metro (Suzhou) Technologies Co., Ltd. 221 Xing Hai Street Suzhou Industrial Park Suzhou, China 215021
Tel: 86-512-62572511 Fax: 86-512-62571517 Email: info@cn.metrologic.com
Japan
Metrologic Japan Co., Ltd. Matsunoya Building, 6 Floor 3-14-8 Higashiueno Taitou-Ku, Tokyo 110-0015 Japan
Tel: 81-03-3839-8511 Fax: 81-03-3839-8519 Email: info@jp.metrologic.com
Brazil
Metrologic do Brasil Ltda. Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil
Tel: 55-11-5182-8226 Fax: 55-11-5182-8315 Email: info@br.metrologic.com
Outside Brazil
Metrologic South America Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil
Tel: 55-11-5182-7273 Fax: 55-11-5182-7198 Email: info@sa.metrologic.com
Asia
South America
Copyright © 2002 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.
ii
Page 4
TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories..................................................................................... 2 Installing the Scanner to the Host (Standard Features) Single Holotrak® Installation ............................................................................. 3 Holotrak® Primary/Secondary Installation ......................................................... 3 Installing the Scanner to the Host (Optional Features) Industrial Controller MX001 Interface Option.................................................... 5 External Speaker Box Option ........................................................................... 6 Hand-held Port Option ...................................................................................... 7 Installing and Running the MetroSet® Program .................................................... 8 Parts of the Scanner........................................................................................... 10 Mounting Bracket Installation ............................................................................. 11 Visual and Audible Indicators ............................................................................. 12 Labels................................................................................................................. 13 Depth of Field and Scan Pattern Characteristics IS8300 Depth of Field and Scan Pattern ........................................................ 14 IS8400 Depth of Field and Scan Pattern ........................................................ 15 IS8500 Depth of Field and Scan Pattern ........................................................ 16 IS8800 Depth of Field and Scan Pattern ........................................................ 17 Maintenance....................................................................................................... 18 Trouble Shooting Guide...................................................................................... 19 Appendix A Design Specification ....................................................................................... 20 Appendix B Default Settings .............................................................................................. 22 Appendix C IS8000 Series Pinout Connections ................................................................. 27 Appendix D Limited Warranty............................................................................................. 29 Appendix E Notices............................................................................................................ 30 Appendix F Patents ........................................................................................................... 32 Index................................................................................................................... 33 iii
Page 5
INTRODUCTION Metrologic's IS8000 series scanners bring the benefits of holography to longrange industrial bar code scanning. Enclosed in rugged NEMA-12 cases for industrial environments, the IS8000 series provides omnidirectional scanning with optional no code/wrong code warning. They can be mounted in any orientation and are capable of primary/secondary setup for added versatility. There are several IS8000 models to choose from depending on the scanning application. The IS8300 produces 5,250 scan lines per second with a depth of field of 457.2 mm (18”)** and a width covering 304.8 mm (12”)** The IS8400 produces 3,360 scan lines per second with a depth of field of 711.2 mm (28”)* and a width covering 558.8 (22”)* The IS8500 produces 5,600 scan lines per second with a depth of field of 711.2 mm (28”)* and a width covering 558.8 (22”)* The IS8800 produces 5,600 scan lines per second with a depth of field of 812.8 mm (32”)* and a width covering 457.2 (18”)*
¾ ¾ ¾ ¾ *
The area defined is based conservatively on a 0.33 mm/0.013” bar code width. Actual scan areas will vary by label size and application. ** The area defined is based conservatively on a 0.25 mm/0.010” bar code width. Actual scan areas will vary by label size and application. Several optional features are also available for the IS8000 series including a hand-held scanner port, Triac output, a high volume external speaker box and object sensor input with the use of a MX001 industrial control interface. All ® scanners can be programmed using Metrologic’s MetroSet configuration program available on CD or downloadable from Metrologic’s web site at www.metrologic.com.
Applications and Protocols The following chart specifies the version identifier for the communication protocol. Scanner IS8300 or IS8800
IS8400 or IS8500
Version Identifier
Communication Protocol(s)
1
RS-232/RS-422/Light Pen Emulation
1L
RS-232/RS-422/Light Pen Emulation Low Speed Option
1
RS-232/RS-422/Light Pen Emulation
1E
RS-232/RS-422/Light Pen Emulation with External Speaker
1L
RS-232/RS-422/Light Pen Emulation Low Speed Option
1LE
RS-232/RS-422/Light Pen Emulation Low Speed Option with External Speaker
1
Page 6
SCANNER AND ACCESSORIES The following is a list of parts included in a standard IS8000 kit: ¾
IS8000 Series HoloTrak® Holographic Scanner
¾
Power Supply
¾
¾
[MLPN 46-46207-US] 12VDC @ 4.16 Amps, 220VAC or
¾
[MLPN 46-46207-UK] 12VDC @ 4.16 Amps, 240VAC or
¾
[MLPN 46-46207-EC] 12VDC @ 4.16 Amps, 120VAC
Communication Cable ¾
¾
[MLPN 52-52702] Standard 2 meter (6 ft.) cable
Mounting Bracket ¾
[MLPN 45-45615] for IS8300 or
¾
[MLPN 45-45616] for IS8400/IS8500/IS8800
¾
Installation and User's Guide [MLPN 00-02377]
¾
MetroSet® Scanner Configuration Software for Windows
Optional Accessories available: ¾
¾
¾
¾
[MLPN MX008] MX008 External Speaker (for use with IS8400 & IS8500 only) ¾
MX008 High Volume Speaker
¾
[MLPN 52-52206] 3.7 meter (12 ft.) Communication Cable
[MLPN 45-45745] MX001 for Single Scanner Setup ¾
MX001 Industrial Controller
¾
[MLPN 52-52708] Communication Cable
[MLPN 45-45718] MX001 for Primary/Secondary Scanner Setup ¾
[MLPN 45-45745] MX001 for Single Scanner Setup
¾
[MLPN 52-52709] Communication “Y” Cable
Cables ¾ ¾
[MLPN 52-52704] 6 meter (20 ft.) IS8000 Series Communication Cable [MLPN 52-52707] 3 meter (10 ft.) IS8000 Secondary Cable (not for use with MX001)
¾ ¾
[MLPN 51-51882] 0.25 meter (10 inch) Tech Secondary Adapter Cable
Replacement Parts ¾
[MLPN 45-45224] Scan Window for IS8300
¾
[MLPN 45-45223] Scan Window for IS8400/IS8500/IS8800
If any item is missing or to order additional items, contact the dealer, distributor or call Metrologic's Customer Service Department at 1-800-ID-METRO or 1-800-436-3876. 2
Page 7
INSTALLING THE SCANNER TO THE HOST (STANDARD FEATURES) Single HoloTrak® Installation To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. Turn off the host system. 2. Connect the communications ® cable to the HoloTrak and to the host. 3. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. 4. Plug the power supply to the scanner. 5. Plug the power supply into the AC outlet to supply power to the scanner. 6. Power up the host system.
HoloTrak Primary/Secondary Feature The primary/secondary feature gives the ability to connect or "daisy-chain" two scanners together to act as one scanner interfacing with only one host. PRIMARY/SECONDARY COVERAGE WITH ONE HOST AND TWO HOLOTRAKS Single Conveyor
Two Conveyors
IS8300
12” (305 mm) to 24” (610 mm)
12” (305 mm) coverage per conveyor
IS8400
22" (559 mm) to 44" (1118 mm)
22” (559 mm) coverage per conveyor
IS8500
22" (559 mm) to 44" (1118 mm)
22” (559 mm) coverage per conveyor
IS8800
18” (457 mm) to 36” (914 mm)
18” (457 mm) coverage per conveyor Continued on next page
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
3
Page 8
INSTALLING THE SCANNER TO THE HOST (STANDARD FEATURES) Primary/Secondary setup continued from previous page.
All equipment must be connected before power-up. After both units complete the power-up diagnostics, the operator will need to program the primary unit with the MetroSet Program provided. Additional Equipment needed:
Primary/Secondary Cable [MLPN 52-52707]
To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1.
Turn off the host system.
2.
Connect the communications cable to ® the HoloTrak primary scanner and to the host.
3.
Connect the Primary/Secondary cable to the primary scanner and the secondary scanner.
4.
Check the AC input requirements of the power supplies for both scanners to make sure the voltages match the AC outlets.
5.
Connect the power supplies to the scanners.
6.
Plug the power supplies into the AC outlets to supply power to the both scanners.
7.
Power up the host system.
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
4
Page 9
INSTALLING THE SCANNER TO THE HOST (OPTIONAL FEATURES) Industrial Controller MX001 Interface Option The MX001 Industrial Control Interface performs three functions. ¾
Through an object sensor input, the scanner can be alerted to any package present in the scan field. The sensor must have a 12V or 5V at 10mA output signal or switch closure (relay) output. The MX001 can also supply 12VDC power at 200mA (max) to the sensor. (MetroSet 2 configuration required)
¾
The MX001 electronic switch or Triac, allows the scanner to control an external device directly by switching on and off a 115 VAC at 10 Amps or 230VAC at 6 Amps output signal. (MetroSet 2 configuration required)
¾
It can alert the user that sensor conditions are not nominal (Sensor Alarm). Special configuration of the MX001 Industrial controller is necessary for proper installation. Please refer to the MX001 Industrial Control Interface Installation and User's Guide [MLPN 00-02173] and the MetroSet 2 documentation for complete details. To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. Only one MX001 can be used in the primary/secondary setting (not shown), and it MUST be connected to the primary scanner.
1.
Turn off the host system.
2.
Connect the communications ® cable to the HoloTrak and to the host.
3.
Connect the External MX001/Triac cable to the HoloTrak and the MX001.
4.
Check the AC input requirements of the power supply for the scanner to make sure the voltage matches the AC outlet.
5.
Connect the power supply to the HoloTrak.
6.
Plug the power supply into the AC outlet.
7.
Power up the host system. Refer to caution statement on page 4.
5
Page 10
INSTALLING THE SCANNER TO THE HOST (OPTIONAL FEATURES) External Speaker Box Option When attached, beeper tones from the scanner are emitted from both the scanner speaker and external speaker to serve as an audible indication of the operation of the scanner. There are 6 beeper options available: ¾ Normal Tone ¾ Tone 2 ¾
Tone 1
¾
Tone 3
¾
Tone 4
¾
No Tone
® Beeper tones can be adjusted by using the MetroSet program.
To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1.
Turn off the host system.
2.
Connect the communications cable to ® the HoloTrak and to the host.
3.
Connect the External MX008 cable to the HoloTrak and the MX008.
4.
Check the AC input requirements of the power supply for the scanner and the MX008 to make sure the voltages match the AC outlets.
5.
Connect the power supply to the HoloTrak.
6.
Plug the power supplies into the AC outlet.
7.
Power up the host system
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
6