Page 1 of 96 Series Product description

Spec sheet · Leuze

96 Series Product description

Spec sheet84 pagesPDF 5.0 MB

Product description and data sheets for the Leuze electronic 96 Series photoelectric sensors, including the LS, LSE, LSS, PRK and HRT 96 models.

Download the PDF5.0 MB

Covers · 3 models

The models it covers

Summary

What is in it

Leuze electronic's product description for the 96 Series of optical sensors. It gives an overview of the series and its features, a sensor selection table, and data sheets for throughbeam, protective throughbeam, retro-reflective and diffuse reflection sensors, including scanners with background suppression such as the HRT 96, with their operating ranges, light sources, supply voltages, outputs, housings and connections.

Its parts

  1. 96 Series - Overview and advantages
  2. Special features of Series 96
  3. Sensor selection table
  4. Data sheets

From the sheet

Key facts from this sheet

Each line names its page in the PDF.

The Leuze electronic 96 Series product description: an overview, a sensor selection table and data sheets for the whole series of photoelectric sensors, with accessories. It covers LS 96 throughbeam pairs (LSS transmitter and LSE receiver), HRT 96 scanners with background suppression, and other 96 Series types such as SLS 96. This summary draws on the overview, the LS 96 and HRT 96 data sheets and the accessory pages.

Read for this summary: pages 1 to 6, 16 to 17, 62 to 63, 72 to 73, 78 to 82 and 84 of 84.

Device
96 Series photoelectric sensors: LS 96 throughbeam pairs (LSS transmitter, LSE receiver) and HRT 96 scanners with background suppression p. 16, 17, 62
Operating voltage
10 … 30VDC with PNP/NPN transistor output; AS-interface or 20 … 230V relay versions also in the series p. 3, 17, 63
Housing
Diecast zinc metal housing with glass optics cover; plastic versions also in the series p. 3, 16, 17, 62, 63
Protection class
IP 67, IP 69K p. 16, 17, 62, 63
Connection
M12 connector or terminal compartment p. 16, 62
Accessories
Mounting systems BT 96, BT 96.1, UMS 96, BT 450.1-96; M12 connectors (KD …); ready-made cables (K-D …) p. 16, 62
HRT 96 range
HRT 96: red light (800mm) or infrared light (1200mm) versions; laser version 100 … 5000mm p. 63, 72
HRT 96 electrical
HRT 96: 300Hz switching frequency; ≤ 35mA, ≤ 75mA with optics heating; light or dark switching (reversible) p. 63
HRT 96 laser
HRT 96 laser: red laser light, 660nm; three switching points; analogue output; 15m against reflective tape p. 3, 72, 73
Temperature
LS 96 and HRT 96: -20°C … +60°C operation, -40°C … +70°C storage; HRT 96 laser: 0°C … +40°C operation p. 17, 63, 73
LS 96 range
LS 96: throughbeam to 150m, infrared light, 500Hz switching frequency p. 3, 16, 17
LS 96 pairs
LS 96M/P-3010-2 = LSS 96M-1070-23 + LSE 96M/P-3010-21; LS 96M/P-3012-2 = LSS 96M-1090-24 + LSE 96M/P-3012-21 p. 17
HRT 96 order codes
HRT 96M/P-1610-1200-21 (Part No. 500 25116); HRT 96M/P-1640-800-21 (500 25124); HRT 96M/P-3360-5000-426 (500 39470) p. 63, 73
M12 cables
K-D M12A-4P-2m-PVC (501 04542), K-D M12A-4P-5m-PVC (501 04544); connectors KD 095-4 (500 31324), KD 095-5 (500 20502) p. 80

What this sheet walks you through

  • Choosing a 96 Series sensor by operating principle p. 3, 4, 5
  • LS 96 throughbeam sensor specifications and order guide p. 16, 17
  • HRT 96 diffuse scanner with background suppression specifications p. 62, 63
  • HRT 96 laser scanner with three switching points p. 72, 73
  • Choosing reflectors and reflective tape p. 78
  • Choosing M12 connectors and ready-made cables p. 79, 80
  • Mounting brackets, mounting systems and the ARH 96 alignment aid p. 81

Good to know

  • Throughbeam sensors need a connector for both the transmitter and the receiver. p. 79
  • Retro-reflective sensors with polarisation filters work only with triad-type plastic reflectors or reflective tape No. 4. p. 78
  • The upper scanning range limit can vary with the reflection properties of the object surface. p. 63
  • The IP 69K test simulates high pressure cleaning without additives; acids and bases are not part of the test. p. 17
  • Specifications are subject to change due to technical progress. p. 2

Questions this sheet answers

What is the scanning range of the Leuze HRT 96?

The order guide lists red light (800mm) and infrared light (1200mm) versions. The HRT 96 laser version scans 100 … 5000mm. p. 63, 72

What are the Leuze LSS 96 and LSE 96?

In an LS 96 throughbeam pair, LSS is the transmitter and LSE the receiver; for example LS 96M/P-3010-2 is LSS 96M-1070-23 plus LSE 96M/P-3010-21. p. 17

What voltage does the Leuze HRT 96 need?

10 … 30VDC, including residual ripple. p. 62, 63

Which cables fit the Leuze 96 Series M12 connector?

Ready-made K-D M12 cables in PVC or PUR, for example K-D M12A-4P-2m-PVC (Part No. 501 04542), or user-configurable KD 095 connectors. p. 79, 80

How far can a Leuze LS 96 throughbeam sensor reach?

The 96 Series throughbeam photoelectric sensors reach up to 150m. p. 3, 16

The whole text · 9 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 8481-84

The file

Size and text

PublisherLeuze electronic
Pages84
PDF5.0 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 4 of 84

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 84
Page 2
Page 2of 84
Page 3
Page 3of 84
Page 4
Page 4of 84

More documents · 1

For the same models