The text of a spec sheet · part 3 of 9
96 Series Product description, pages 21 to 30
Pages 21 to 30 of 84
The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze HRT-96, Leuze LSE-96 and Leuze LSS-96
Page 21
Leuze electronic LS 96 Specifications
Tables
Optical data
Typ. operating range limit 1) Operating range 2) Light source Wavelength
65m models
65m
150m
0 … 65m 0 … 50m LED (modulated light) 880nm (infrared)
0 … 150m 0 … 120m
0
0
Timing
Electrical data Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Bias current Sensitivity
150
65m models Typ. response behaviour
Indicators LED green LED yellow LED yellow flashing ready light path free light path free, no performance reserve
Mechanical data
Metal housing
Plastic housing
Housing Optics cover Weight Connection type diecast zinc glass 380g terminals polycarbonate plastic 150g terminals
1,0 0,8 0,6 0,4 0,2 0 -0,2 -0,4 -0,6 -0,8 -1,0 y2 y1 0
10
20
30
40
50
60
70
Distance x [m]
Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied
120
Diagrams
20 … 230VAC, 50/60Hz 20 … 230VDC ≤ 1.5VA relay, 1 change-over contact break-contact/make-contact 250VAC/DC 250VAC, 3A/30V, 3A 750VA, cosϕ=1 adjustable
Misalignment y [m]
Operating voltage UB
65
Operating range [m] Typ. operating range limit [m]
20Hz 25ms ≤ 200ms
-20°C … +60°C/-40°C … +70°C 1, 2, 3 II, all-insulated IP 67, IP 69K 6) IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2
150m models Typ. response behaviour 3,5
Misalignment y [m]
Switching frequency Response time Delay before start-up
50
150m models
2,5 y2
1,5 0,5 0 -0,5 -1,5 y1
-2,5 -3,5
0
20
Options
40
60
80 100 120 140 160
Distance x [m]
Switching delay (slow oper./release)
0 … 10s (separately adjustable)
1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test y2 y1 x
Remarks ! LS 96K/R-131P-2 P= Reduction M16
Housing Light source Connection Features metal plastic infrared light (50m) infrared light (120m) terminals switching delay UL homologation
! !
!
! ! !
!
!
! ! !
! ! !
LS 96 K/R… - 09 LS 96 M/R… - 09
LS 96K/R-131P-2 Part No. 500 30405 (Tr) Part No. 500 30406 (Re)
! !
LS 96M/R-3310-2 Part No. 500 80081 (Tr) Part No. 500 31651 (Re)
Equipment #
LS 96M/R-1310-2 Part No. 500 80081 (Tr) Part No. 500 80080 (Re)
Order code "
LS 96K/R-1320-2 Part No. 500 25253 (Tr) Part No. 500 25256 (Re)
Selection table
LS 96K/R-1310-2 Part No. 500 25253 (Tr) Part No. 500 25257 (Re)
Order guide
! !
! !
LS LSS LSE
= = =
Pair consisting of Transmitter Receiver
LS 96K/R-1310-2 LSS 96K-1350-26 LSE 96K/R-1310-25 LS 96K/R-1320-2 LSS 96K-1350-26 LSE 96K/R-1320-25 LS 96M/R-1310-2 LSS 96M-1350-26 LSE 96M/R-1310-25 LS 96M/R-3310-2 LSS 96M-1350-26 LSE 96M/R-3310-25 LS 96K/R-131P-2 LSS 96K-135P-26 LSE 96K/R-131P-25 0603
– 19 –
Page 22
Leuze electronic LS 96
Throughbeam photoelectric sensors Dimensioned drawing
39m 20-230 V AC / DC
A2 LS
! Throughbeam photoelectric sensors with high performance reserve in red light ! Wide angle version for easy alignment ! Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application ! All-mains design 20 … 230VAC/DC with relay output ! Relay with change-over contact, sensitivity adjustment and delay before start-up for optimal adaptation to the application ! Connection via comfortable terminal compartment up to 1.5mm2
We reserve the right to make changes • 96_a06e.fm
ISO 9001
C
A B C D E F G H
Indicator diode green Indicator diode yellow Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment
Electrical connection (example)
UL US LISTED
Transmitter
IEC 60947...
IEC 60947...
IP 69K IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, BT 96.4, UMS 96, BT 450.1-96) ! Spark extinction ! Alignment aid ARH 96
Leuze electronic GmbH + Co. KG www.leuze.de
Receiver
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 20 –
LS 96 M/R-176W-2 - 05
Page 23
Leuze electronic LS 96 Specifications
Tables 0
Optical data
Typ. operating range limit 1) Operating range 2) Light source Wavelength
0 … 39m 0 … 30m LED (modulated light) 660nm (red light)
30
39
Operating range [m] Typ. operating range limit [m]
Timing Switching frequency Response time Delay before start-up
20Hz 25ms ≤ 200ms
Electrical data Operating voltage UB
20 … 230VAC, 50/60Hz 20 … 230VDC ≤ 1.5VA relay, 1 change-over contact break-contact/make-contact 250VAC/DC 250VAC, 3A/30V, 3A 750VA, cosϕ=1 adjustable
Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Bias current Sensitivity
Indicators ready light path free light path free, no performance reserve
Mechanical data
Metal housing
Housing Optics cover Weight Connection type diecast zinc glass 380g terminals transmitter cable 3x0.5mm2 (oil flex 110), 1.5m receiver cable 3x0.5mm2 (oil flex 110), 1.5m
Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied
-20°C … +60°C/-40°C … +70°C 1, 2, 3 II, all-insulated IP 67, IP 69K 6) 1 (acc. to EN 60825-1) IEC 60947-5-2
Diagrams Typ. response behaviour Misalignment y [mm]
LED green LED yellow LED yellow flashing
1250 1000 750 500 250 0 -250 -500 -750 -1000 -1250 y2 y1 0
10
20
30
40
Distance x [m]
1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test y2 y1 x
Remarks
Selection table
! Angle at a distance of 3m: transmitter: angle of radiation typ. 10° receiver: receiving angle typ. 12° ! Cable version wire assignment: 1,2 = supply 3,4 = break-contact
Order code "
Equipment # Housing Light source Connection metal red light (30m) terminals cable tail 1.5m
LS 96M/R-176W-2 Part No. 500 32004 (Tr) Part No. 500 32003 (Re)
Order guide
! ! !
LS LSS LSE
= = =
Pair consisting of Transmitter Receiver
LS 96M/R-176W-2 LSS 96M-175W-26 LSE 96M/R-176W-25
LS 96 M/R-176W-2 - 05
0603
– 21 –
Page 24
Leuze electronic SLS 96
Protective throughbeam photoelectric sensors Dimensioned drawing
65m 39m 10 - 30 V DC
BG geprüft
! Protective throughbeam photoelectric sensor cat. 2 (testing) with high performance reserve in visible red light or infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application ! 2 indicators each at the transmitter and receiver for displaying their status when commissioning and in operation ! Optics heating for use with low temperatures ! Connection via M12 connector or terminal compartment
We reserve the right to make changes • 96_a07e.fm
ISO 9001
IEC 60947...
C
Indicator diode green Indicator diode yellow Transmitter/receiver Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry
Electrical connection
UL US
Transmitter
LISTED
IEC 60947...
A B C D E F G H I
Receiver
IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …) ! Alignment aid ARH 96 ! Test-monitoring units: - available only from Leuze lumiflex
Leuze electronic GmbH + Co. KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 22 –
SLS 96 M/P… - 07
Page 25
Leuze electronic SLS 96 Specifications Optical data
Typ. operating range limit 1) Operating range 2) Light source Wavelength
Tables Infrared light
Red light
0 … 65m 0 … 50m LED (modulated light) 880nm
0 … 39m 0 … 30m LED (modulated light) 660nm
Timing Sensor switching frequency Sensor response time Delay before start-up
500Hz 1ms ≤ 200ms
Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current
10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 50mA PNP transistor light switching ≥ (UB -2V)/≤ 2V max. 100mA
Indicators LED green Receiver LED yellow LED yellow flashing Transmitter LED yellow ready light path free light path free, no performance reserve
Mechanical data
Metal housing
Housing Optics cover Weight Connection type diecast zinc glass 380g terminals or M12 connector
Remarks ! The protective throughbeam photoelectric sensor is a contactless active protective device only in connection with a safetyrelevant control system, in which the cyclical testing of transmitter and receiver is carried out according to EN 61496-1, category 2 (testing). ! The power supply unit used to operate the photoelectric sensor has to be able to compensate for changes and interruptions of the supply voltage acc. to EN 61496-1. Minimum blackening object dia: Ø 28mm.
transmitter active
Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied
-20°C … +60°C/-40°C … +70°C 1, 2, 3 II, all-insulated IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2
Options Optics heating Low temperature Activation input activ Transmitter active/not active Activation/disable delay Input resistance for temperature changes, prevents fogging to -35°C ≥ 8V/≤ 2V ≤ 1ms 10KΩ ± 10%
1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 250VAC
SLS = SLSS = SLSE =
Connection Features
!
!
!
! !
!
! !
!
! !
!
SLS 96 M/P… - 07
! !
SLS 96M/P-1200-T2-4 Part No. 500 31249 (Tr) Part No. 500 31250 (Re)
Light source metal plastic red light (30m) infrared light (50m) terminals M12 connector optics heating/low temperature activation input filter for multi-axis operation
SLS 96M/P-1200-T2-2 Part No. 500 25209 (Tr) Part No. 500 31562 (Re)
Housing
SLS 96M/P-1071-T2-4 Part No. 500 80478 (Tr) Part No. 500 80479 (Re)
Equipment #
SLS 96M/P-1071-T2-2 Part No. 500 29454 (Tr) Part No. 500 29455 (Re)
Order code "
SLS 96M/P-1070-T2-4 Part No. 500 25215 (Tr) Part No. 500 25193 (Re)
Selection table
SLS 96M/P-1070-T2-2 Part No. 500 25213 (Tr) Part No. 500 25192 (Re)
Order guide
!
!
!
!
!
! ! ! !
! !
!
Pair consisting of Transmitter Receiver
SLS 96M/P-1070-T2-2 SLSS 96M-1080-T2-24 SLSE 96M/P-1070-T2-21 SLS 96M/P-1070-T2-4 SLSS 96M-1080-T2-45 SLSE 96M/P-1070-T2-41 SLS 96M/P-1071-T2-2 SLSS 96M-1090-T2-24 SLSE 96M/P-1071-T2-21 SLS 96M/P-1071-T2-4 SLSS 96M-1090-T2-45 SLSE 96M/P-1071-T2-41 SLS 96M/P-1200-T2-2 SLSS 96M-1210-T2-24 SLSE 96M/P-1200-T2-21 SLS 96M/P-1200-T2-4 SLSS 96M-1210-T2-45 SLSE 96M/P-1200-T2-41
0603
– 23 –
Page 26
Leuze electronic SLS 96
Protective throughbeam photoelectric sensors Dimensioned drawing
65m 39m 10 - 30 V DC
BG geprüft
! Protective throughbeam photoelectric sensor cat. 2 (testing) with high performance reserve in visible red light or infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application ! 2 indicators each at the transmitter and receiver for displaying their status when commissioning and in operation ! Optics heating for use with low temperatures ! Connection via M12 connector or terminal compartment
We reserve the right to make changes • 96_a12e.fm
ISO 9001
IEC 60947...
C
Indicator diode green Indicator diode yellow Transmitter/receiver Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry
Electrical connection
UL US
Transmitter
LISTED
IEC 60947...
A B C D E F G H I
Receiver
IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …) ! Alignment aid ARH 96 ! Test-monitoring units: - available only from Leuze lumiflex
Leuze electronic GmbH + Co. KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 24 –
SLS 96 K/P… - 07
Page 27
Leuze electronic SLS 96 Specifications Optical data
Typ. operating range limit 1) Operating range 2) Light source Wavelength
Tables Infrared light
Red light
0 … 65m 0 … 50m LED (modulated light) 880nm
0 … 39m 0 … 30m LED (modulated light) 660nm
Timing Sensor switching frequency Sensor response time Delay before start-up
500Hz 1ms ≤ 200ms
Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current
10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 50mA PNP transistor light switching ≥ (UB -2V)/≤ 2V max. 100mA
Indicators LED green Receiver LED yellow LED yellow flashing Transmitter LED yellow ready light path free light path free, no performance reserve
Mechanical data
Plastic housing
Housing Optics cover Weight Connection type polycarbonate plastic 150g terminals or M12 connector
Remarks ! The protective throughbeam photoelectric sensor is a contactless active protective device only in connection with a safetyrelevant control system, in which the cyclical testing of transmitter and receiver is carried out according to EN 61496-1, category 2 (testing). ! The power supply unit used to operate the photoelectric sensor has to be able to compensate for changes and interruptions of the supply voltage acc. to EN 61496-1. Minimum blackening object dia: Ø 28mm.
transmitter active
Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied
-20°C … +60°C/-40°C … +70°C 1, 2, 3 II, all-insulated IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2
Options Optics heating Low temperature Activation input activ Transmitter active/not active Activation/disable delay Input resistance for temperature changes, prevents fogging to -35°C ≥ 8V/≤ 2V ≤ 1ms 10KΩ ± 10%
1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 250VAC
SLS = SLSS = SLSE =
Connection Features
SLS 96K/P-1207-T2-4 Part No. 500 28011 (Tr) Part No. 500 41109 (Re)
Light source metal plastic red light (30m) infrared light (50m) terminals M12 connector optics heating/low temp. activation input filter for multi-axis operation
SLS 96K/P-1207-T2-2 Part No. 500 28009 (Tr) Part No. 500 35078 (Re)
Housing
SLS 96K/P-1200-T2-4 Part No. 500 28011 (Tr) Part No. 500 28012 (Re)
Equipment #
SLS 96K/P-1200-T2-2 Part No. 500 28009 (Tr) Part No. 500 28010 (Re)
Order code "
SLS 96K/P-1070-T2-4 Part No. 500 31559 (Tr) Part No. 500 31561 (Re)
Selection table
SLS 96K/P-1070-T2-2 Part No. 500 81292 (Tr) Part No. 500 81293 (Re)
Order guide
!
!
! !
! !
! !
! !
! !
! ! !
!
!
! !
!
SLS 96 K/P… - 07
!
! ! !
! !
Pair consisting of Transmitter Receiver
SLS 96K/P-1070-T2-2 SLSS 96K-1080-T2-24 SLSE 96K/P-1070-T2-21 SLS 96K/P-1070-T2-4 SLSS 96K-1080-T2-45 SLSE 96K/P-1070-T2-41 SLS 96K/P-1200-T2-2 SLSS 96K-1210-T2-24 SLSE 96K/P-1200-T2-21 SLS 96K/P-1200-T2-4 SLSS 96K-1210-T2-45 SLSE 96K/P-1200-T2-41 SLS 96K/P-1207-T2-2 SLSS 96K-1210-T2-24 SLSE 96K/P-1207-T2-21 SLS 96K/P-1207-T2-4 SLSS 96K-1210-T2-45 SLSE 96K/P-1207-T2-41
0603
– 25 –
Page 28
Leuze electronic LS 96
Throughbeam photoelectric sensors Dimensioned drawing
39m
! Throughbeam photoelectric sensors with high performance reserve in red light ! Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application ! Receiver with integrated AS-i slave technology ! Transmitter without integrated AS-i slave technology; receives voltage supply via AS-i line ! Wide angle version to simplify the alignment
ISO 9001
We reserve the right to make changes • 96_a09e.fm
IEC 60947...
C
A B C D E
Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Countersinking for SK nut M5, 4.2 deep
Electrical connection
UL US LISTED
IEC 60947...
IP 69K IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors ! Ready-made cables (K-D …) ! Alignment aid ARH 96
AS-i Accessories: (available separately)
! Bus terminals ! AS-i ribbon cable ! Address programming device ! Coupling modules, intermediate cables, etc. Leuze electronic GmbH + Co. KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 26 –
LS 96M/A-182W-4 - 06
Page 29
Leuze electronic LS 96 Specifications
Tables 0
Optical data
Typ. operating range limit 1) Operating range 2) Light source Wavelength
0 … 39m 0 … 30m LED (modulated light) 660nm (red light)
30
39
Operating range [m] Typ. operating range limit [m]
Timing Sensor switching frequency Sensor response time Delay before start-up
500Hz 1ms ≤ 200ms
Electrical data Operating voltage UB Bias current receiver Bias current transmitter
26.5 … 31.6V (according to AS-i specification) ≤ 35mA ≤ 15mA
Indicators LED green LED yellow LED yellow flashing ready light path free light path free, no performance reserve
Mechanical data
Metal housing
Housing Optics cover Weight Connection type diecast zinc glass 380g M12 connector
Environmental data -20°C … +60°C/-40°C … +70°C 1, 2 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2
Diagrams Typ. response behaviour 400
Misalignment y [mm]
Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied
AS-i data for receiver I/O code ID code Cycle time acc. to AS-i specification AS-i standard according to profile
1 1 5ms S-1.1
300 200 0 -100
Assignment: data bits Programming (host level) Ø no reflection Switching outD0 put 1 reflection Ø active D1 Warning output autoControl 1 not active Ø sensor not ready D2 Ready output 1 sensor ready Ø *D3 NC 1 * default = 1
-300 0
5
10 15 20 25 30 35 40 45 50
Distance x [m] y2 y1 x
Assignment: parameter bits
System input
*P0 NC
System input
*P1 Light/dark switching
System input
*P2 NC *P3 NC
Programming (host level) Ø 1 Ø dark switching 1 light switching Ø 1 Ø 1
Order guide Transmitter and receiver Transmitter Receiver y1
-200 -400
1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test y2
100
Designation
Part No.
LS 96M/A-182W-4 LSS 96 M-180W-44 LSE 96 M/A-182W-44
500 82040 500 82039
System parameter System parameter System parameter System parameter
Remarks ! The transmitter has no integrated AS-i slave technology. ! The low current consumption of the transmitter enables power supply via AS-i line. ! Transmitter and receiver behave like a slave in an AS-i branch. Angle at 3m distance: Transmitter: Angle of radiation typ.: 10° Receiver: Receiving angle typ.: 12°
LS 96M/A-182W-4 - 06
0603
– 27 –
Page 30
Leuze electronic RK 96
Retro-reflective photoelectric sensors Dimensioned drawing
18m 10 - 30 V DC
A2 LS
! Retro-reflective photoelectric sensors with a long operating range ! Invisible infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67/ IP 69K for industrial application ! Complementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the application ! Connection via comfortable terminal compartment up to 1.5mm²
We reserve the right to make changes • 96_b01e.fm
ISO 9001
IEC 60947...
C
A B C D E F G H
Indicator diode green Indicator diode yellow Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment
UL US
Electrical connection
LISTED
IEC 60947...
IP 69K IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, UMS 96, BT 450.1-96) ! Reflectors ! Reflective tapes
Leuze electronic GmbH + Co. KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 28 –
RK 96 M/P-1440-21 - 05