Page 21

Leuze electronic LS 96 Specifications

Tables

Optical data

Typ. operating range limit 1) Operating range 2) Light source Wavelength

65m models

65m

150m

0 … 65m 0 … 50m LED (modulated light) 880nm (infrared)

0 … 150m 0 … 120m

0

0

Timing

Electrical data Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Bias current Sensitivity

150

65m models Typ. response behaviour

Indicators LED green LED yellow LED yellow flashing ready light path free light path free, no performance reserve

Mechanical data

Metal housing

Plastic housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals polycarbonate plastic 150g terminals

1,0 0,8 0,6 0,4 0,2 0 -0,2 -0,4 -0,6 -0,8 -1,0 y2 y1 0

10

20

30

40

50

60

70

Distance x [m]

Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied

120

Diagrams

20 … 230VAC, 50/60Hz 20 … 230VDC ≤ 1.5VA relay, 1 change-over contact break-contact/make-contact 250VAC/DC 250VAC, 3A/30V, 3A 750VA, cosϕ=1 adjustable

Misalignment y [m]

Operating voltage UB

65

Operating range [m] Typ. operating range limit [m]

20Hz 25ms ≤ 200ms

-20°C … +60°C/-40°C … +70°C 1, 2, 3 II, all-insulated IP 67, IP 69K 6) IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2

150m models Typ. response behaviour 3,5

Misalignment y [m]

Switching frequency Response time Delay before start-up

50

150m models

2,5 y2

1,5 0,5 0 -0,5 -1,5 y1

-2,5 -3,5

0

20

Options

40

60

80 100 120 140 160

Distance x [m]

Switching delay (slow oper./release)

0 … 10s (separately adjustable)

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test y2 y1 x

Remarks ! LS 96K/R-131P-2 P= Reduction M16

Housing Light source Connection Features metal plastic infrared light (50m) infrared light (120m) terminals switching delay UL homologation

! !

!

! ! !

!

!

! ! !

! ! !

LS 96 K/R… - 09 LS 96 M/R… - 09

LS 96K/R-131P-2 Part No. 500 30405 (Tr) Part No. 500 30406 (Re)

! !

LS 96M/R-3310-2 Part No. 500 80081 (Tr) Part No. 500 31651 (Re)

Equipment #

LS 96M/R-1310-2 Part No. 500 80081 (Tr) Part No. 500 80080 (Re)

Order code "

LS 96K/R-1320-2 Part No. 500 25253 (Tr) Part No. 500 25256 (Re)

Selection table

LS 96K/R-1310-2 Part No. 500 25253 (Tr) Part No. 500 25257 (Re)

Order guide

! !

! !

LS LSS LSE

= = =

Pair consisting of Transmitter Receiver

LS 96K/R-1310-2 LSS 96K-1350-26 LSE 96K/R-1310-25 LS 96K/R-1320-2 LSS 96K-1350-26 LSE 96K/R-1320-25 LS 96M/R-1310-2 LSS 96M-1350-26 LSE 96M/R-1310-25 LS 96M/R-3310-2 LSS 96M-1350-26 LSE 96M/R-3310-25 LS 96K/R-131P-2 LSS 96K-135P-26 LSE 96K/R-131P-25 0603

– 19 –

Page 22

Leuze electronic LS 96

Throughbeam photoelectric sensors Dimensioned drawing

39m 20-230 V AC / DC

A2 LS

! Throughbeam photoelectric sensors with high performance reserve in red light ! Wide angle version for easy alignment ! Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application ! All-mains design 20 … 230VAC/DC with relay output ! Relay with change-over contact, sensitivity adjustment and delay before start-up for optimal adaptation to the application ! Connection via comfortable terminal compartment up to 1.5mm2

We reserve the right to make changes • 96_a06e.fm

ISO 9001

C

A B C D E F G H

Indicator diode green Indicator diode yellow Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment

Electrical connection (example)

UL US LISTED

Transmitter

IEC 60947...

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, BT 96.4, UMS 96, BT 450.1-96) ! Spark extinction ! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG www.leuze.de

Receiver

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 20 –

LS 96 M/R-176W-2 - 05

Page 23

Leuze electronic LS 96 Specifications

Tables 0

Optical data

Typ. operating range limit 1) Operating range 2) Light source Wavelength

0 … 39m 0 … 30m LED (modulated light) 660nm (red light)

30

39

Operating range [m] Typ. operating range limit [m]

Timing Switching frequency Response time Delay before start-up

20Hz 25ms ≤ 200ms

Electrical data Operating voltage UB

20 … 230VAC, 50/60Hz 20 … 230VDC ≤ 1.5VA relay, 1 change-over contact break-contact/make-contact 250VAC/DC 250VAC, 3A/30V, 3A 750VA, cosϕ=1 adjustable

Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Bias current Sensitivity

Indicators ready light path free light path free, no performance reserve

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals transmitter cable 3x0.5mm2 (oil flex 110), 1.5m receiver cable 3x0.5mm2 (oil flex 110), 1.5m

Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied

-20°C … +60°C/-40°C … +70°C 1, 2, 3 II, all-insulated IP 67, IP 69K 6) 1 (acc. to EN 60825-1) IEC 60947-5-2

Diagrams Typ. response behaviour Misalignment y [mm]

LED green LED yellow LED yellow flashing

1250 1000 750 500 250 0 -250 -500 -750 -1000 -1250 y2 y1 0

10

20

30

40

Distance x [m]

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test y2 y1 x

Remarks

Selection table

! Angle at a distance of 3m: transmitter: angle of radiation typ. 10° receiver: receiving angle typ. 12° ! Cable version wire assignment: 1,2 = supply 3,4 = break-contact

Order code "

Equipment # Housing Light source Connection metal red light (30m) terminals cable tail 1.5m

LS 96M/R-176W-2 Part No. 500 32004 (Tr) Part No. 500 32003 (Re)

Order guide

! ! !

LS LSS LSE

= = =

Pair consisting of Transmitter Receiver

LS 96M/R-176W-2 LSS 96M-175W-26 LSE 96M/R-176W-25

LS 96 M/R-176W-2 - 05

0603

– 21 –

Page 24

Leuze electronic SLS 96

Protective throughbeam photoelectric sensors Dimensioned drawing

65m 39m 10 - 30 V DC

BG geprüft

! Protective throughbeam photoelectric sensor cat. 2 (testing) with high performance reserve in visible red light or infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application ! 2 indicators each at the transmitter and receiver for displaying their status when commissioning and in operation ! Optics heating for use with low temperatures ! Connection via M12 connector or terminal compartment

We reserve the right to make changes • 96_a07e.fm

ISO 9001

IEC 60947...

C

Indicator diode green Indicator diode yellow Transmitter/receiver Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry

Electrical connection

UL US

Transmitter

LISTED

IEC 60947...

A B C D E F G H I

Receiver

IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …) ! Alignment aid ARH 96 ! Test-monitoring units: - available only from Leuze lumiflex

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 22 –

SLS 96 M/P… - 07

Page 25

Leuze electronic SLS 96 Specifications Optical data

Typ. operating range limit 1) Operating range 2) Light source Wavelength

Tables Infrared light

Red light

0 … 65m 0 … 50m LED (modulated light) 880nm

0 … 39m 0 … 30m LED (modulated light) 660nm

Timing Sensor switching frequency Sensor response time Delay before start-up

500Hz 1ms ≤ 200ms

Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current

10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 50mA PNP transistor light switching ≥ (UB -2V)/≤ 2V max. 100mA

Indicators LED green Receiver LED yellow LED yellow flashing Transmitter LED yellow ready light path free light path free, no performance reserve

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals or M12 connector

Remarks ! The protective throughbeam photoelectric sensor is a contactless active protective device only in connection with a safetyrelevant control system, in which the cyclical testing of transmitter and receiver is carried out according to EN 61496-1, category 2 (testing). ! The power supply unit used to operate the photoelectric sensor has to be able to compensate for changes and interruptions of the supply voltage acc. to EN 61496-1. Minimum blackening object dia: Ø 28mm.

transmitter active

Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

-20°C … +60°C/-40°C … +70°C 1, 2, 3 II, all-insulated IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2

Options Optics heating Low temperature Activation input activ Transmitter active/not active Activation/disable delay Input resistance for temperature changes, prevents fogging to -35°C ≥ 8V/≤ 2V ≤ 1ms 10KΩ ± 10%

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 250VAC

SLS = SLSS = SLSE =

Connection Features

!

!

!

! !

!

! !

!

! !

!

SLS 96 M/P… - 07

! !

SLS 96M/P-1200-T2-4 Part No. 500 31249 (Tr) Part No. 500 31250 (Re)

Light source metal plastic red light (30m) infrared light (50m) terminals M12 connector optics heating/low temperature activation input filter for multi-axis operation

SLS 96M/P-1200-T2-2 Part No. 500 25209 (Tr) Part No. 500 31562 (Re)

Housing

SLS 96M/P-1071-T2-4 Part No. 500 80478 (Tr) Part No. 500 80479 (Re)

Equipment #

SLS 96M/P-1071-T2-2 Part No. 500 29454 (Tr) Part No. 500 29455 (Re)

Order code "

SLS 96M/P-1070-T2-4 Part No. 500 25215 (Tr) Part No. 500 25193 (Re)

Selection table

SLS 96M/P-1070-T2-2 Part No. 500 25213 (Tr) Part No. 500 25192 (Re)

Order guide

!

!

!

!

!

! ! ! !

! !

!

Pair consisting of Transmitter Receiver

SLS 96M/P-1070-T2-2 SLSS 96M-1080-T2-24 SLSE 96M/P-1070-T2-21 SLS 96M/P-1070-T2-4 SLSS 96M-1080-T2-45 SLSE 96M/P-1070-T2-41 SLS 96M/P-1071-T2-2 SLSS 96M-1090-T2-24 SLSE 96M/P-1071-T2-21 SLS 96M/P-1071-T2-4 SLSS 96M-1090-T2-45 SLSE 96M/P-1071-T2-41 SLS 96M/P-1200-T2-2 SLSS 96M-1210-T2-24 SLSE 96M/P-1200-T2-21 SLS 96M/P-1200-T2-4 SLSS 96M-1210-T2-45 SLSE 96M/P-1200-T2-41

0603

– 23 –

Page 26

Leuze electronic SLS 96

Protective throughbeam photoelectric sensors Dimensioned drawing

65m 39m 10 - 30 V DC

BG geprüft

! Protective throughbeam photoelectric sensor cat. 2 (testing) with high performance reserve in visible red light or infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application ! 2 indicators each at the transmitter and receiver for displaying their status when commissioning and in operation ! Optics heating for use with low temperatures ! Connection via M12 connector or terminal compartment

We reserve the right to make changes • 96_a12e.fm

ISO 9001

IEC 60947...

C

Indicator diode green Indicator diode yellow Transmitter/receiver Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry

Electrical connection

UL US

Transmitter

LISTED

IEC 60947...

A B C D E F G H I

Receiver

IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …) ! Alignment aid ARH 96 ! Test-monitoring units: - available only from Leuze lumiflex

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 24 –

SLS 96 K/P… - 07

Page 27

Leuze electronic SLS 96 Specifications Optical data

Typ. operating range limit 1) Operating range 2) Light source Wavelength

Tables Infrared light

Red light

0 … 65m 0 … 50m LED (modulated light) 880nm

0 … 39m 0 … 30m LED (modulated light) 660nm

Timing Sensor switching frequency Sensor response time Delay before start-up

500Hz 1ms ≤ 200ms

Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current

10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 50mA PNP transistor light switching ≥ (UB -2V)/≤ 2V max. 100mA

Indicators LED green Receiver LED yellow LED yellow flashing Transmitter LED yellow ready light path free light path free, no performance reserve

Mechanical data

Plastic housing

Housing Optics cover Weight Connection type polycarbonate plastic 150g terminals or M12 connector

Remarks ! The protective throughbeam photoelectric sensor is a contactless active protective device only in connection with a safetyrelevant control system, in which the cyclical testing of transmitter and receiver is carried out according to EN 61496-1, category 2 (testing). ! The power supply unit used to operate the photoelectric sensor has to be able to compensate for changes and interruptions of the supply voltage acc. to EN 61496-1. Minimum blackening object dia: Ø 28mm.

transmitter active

Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

-20°C … +60°C/-40°C … +70°C 1, 2, 3 II, all-insulated IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2

Options Optics heating Low temperature Activation input activ Transmitter active/not active Activation/disable delay Input resistance for temperature changes, prevents fogging to -35°C ≥ 8V/≤ 2V ≤ 1ms 10KΩ ± 10%

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 250VAC

SLS = SLSS = SLSE =

Connection Features

SLS 96K/P-1207-T2-4 Part No. 500 28011 (Tr) Part No. 500 41109 (Re)

Light source metal plastic red light (30m) infrared light (50m) terminals M12 connector optics heating/low temp. activation input filter for multi-axis operation

SLS 96K/P-1207-T2-2 Part No. 500 28009 (Tr) Part No. 500 35078 (Re)

Housing

SLS 96K/P-1200-T2-4 Part No. 500 28011 (Tr) Part No. 500 28012 (Re)

Equipment #

SLS 96K/P-1200-T2-2 Part No. 500 28009 (Tr) Part No. 500 28010 (Re)

Order code "

SLS 96K/P-1070-T2-4 Part No. 500 31559 (Tr) Part No. 500 31561 (Re)

Selection table

SLS 96K/P-1070-T2-2 Part No. 500 81292 (Tr) Part No. 500 81293 (Re)

Order guide

!

!

! !

! !

! !

! !

! !

! ! !

!

!

! !

!

SLS 96 K/P… - 07

!

! ! !

! !

Pair consisting of Transmitter Receiver

SLS 96K/P-1070-T2-2 SLSS 96K-1080-T2-24 SLSE 96K/P-1070-T2-21 SLS 96K/P-1070-T2-4 SLSS 96K-1080-T2-45 SLSE 96K/P-1070-T2-41 SLS 96K/P-1200-T2-2 SLSS 96K-1210-T2-24 SLSE 96K/P-1200-T2-21 SLS 96K/P-1200-T2-4 SLSS 96K-1210-T2-45 SLSE 96K/P-1200-T2-41 SLS 96K/P-1207-T2-2 SLSS 96K-1210-T2-24 SLSE 96K/P-1207-T2-21 SLS 96K/P-1207-T2-4 SLSS 96K-1210-T2-45 SLSE 96K/P-1207-T2-41

0603

– 25 –

Page 28

Leuze electronic LS 96

Throughbeam photoelectric sensors Dimensioned drawing

39m

! Throughbeam photoelectric sensors with high performance reserve in red light ! Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application ! Receiver with integrated AS-i slave technology ! Transmitter without integrated AS-i slave technology; receives voltage supply via AS-i line ! Wide angle version to simplify the alignment

ISO 9001

We reserve the right to make changes • 96_a09e.fm

IEC 60947...

C

A B C D E

Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Countersinking for SK nut M5, 4.2 deep

Electrical connection

UL US LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors ! Ready-made cables (K-D …) ! Alignment aid ARH 96

AS-i Accessories: (available separately)

! Bus terminals ! AS-i ribbon cable ! Address programming device ! Coupling modules, intermediate cables, etc. Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 26 –

LS 96M/A-182W-4 - 06

Page 29

Leuze electronic LS 96 Specifications

Tables 0

Optical data

Typ. operating range limit 1) Operating range 2) Light source Wavelength

0 … 39m 0 … 30m LED (modulated light) 660nm (red light)

30

39

Operating range [m] Typ. operating range limit [m]

Timing Sensor switching frequency Sensor response time Delay before start-up

500Hz 1ms ≤ 200ms

Electrical data Operating voltage UB Bias current receiver Bias current transmitter

26.5 … 31.6V (according to AS-i specification) ≤ 35mA ≤ 15mA

Indicators LED green LED yellow LED yellow flashing ready light path free light path free, no performance reserve

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g M12 connector

Environmental data -20°C … +60°C/-40°C … +70°C 1, 2 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2

Diagrams Typ. response behaviour 400

Misalignment y [mm]

Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

AS-i data for receiver I/O code ID code Cycle time acc. to AS-i specification AS-i standard according to profile

1 1 5ms S-1.1

300 200 0 -100

Assignment: data bits Programming (host level) Ø no reflection Switching outD0 put 1 reflection Ø active D1 Warning output autoControl 1 not active Ø sensor not ready D2 Ready output 1 sensor ready Ø *D3 NC 1 * default = 1

-300 0

5

10 15 20 25 30 35 40 45 50

Distance x [m] y2 y1 x

Assignment: parameter bits

System input

*P0 NC

System input

*P1 Light/dark switching

System input

*P2 NC *P3 NC

Programming (host level) Ø 1 Ø dark switching 1 light switching Ø 1 Ø 1

Order guide Transmitter and receiver Transmitter Receiver y1

-200 -400

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test y2

100

Designation

Part No.

LS 96M/A-182W-4 LSS 96 M-180W-44 LSE 96 M/A-182W-44

500 82040 500 82039

System parameter System parameter System parameter System parameter

Remarks ! The transmitter has no integrated AS-i slave technology. ! The low current consumption of the transmitter enables power supply via AS-i line. ! Transmitter and receiver behave like a slave in an AS-i branch. Angle at 3m distance: Transmitter: Angle of radiation typ.: 10° Receiver: Receiving angle typ.: 12°

LS 96M/A-182W-4 - 06

0603

– 27 –

Page 30

Leuze electronic RK 96

Retro-reflective photoelectric sensors Dimensioned drawing

18m 10 - 30 V DC

A2 LS

! Retro-reflective photoelectric sensors with a long operating range ! Invisible infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67/ IP 69K for industrial application ! Complementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the application ! Connection via comfortable terminal compartment up to 1.5mm²

We reserve the right to make changes • 96_b01e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H

Indicator diode green Indicator diode yellow Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment

UL US

Electrical connection

LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, UMS 96, BT 450.1-96) ! Reflectors ! Reflective tapes

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 28 –

RK 96 M/P-1440-21 - 05