Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a spec sheet · part 5 of 9

96 Series Product description, pages 41 to 50

Pages 41 to 50 of 84

The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze HRT-96, Leuze LSE-96 and Leuze LSS-96

Page 41

Leuze electronic PRK 96 Specifications

Tables

Optical data

10m models

Typ. operating range limit (TK(S) 100x100) 1) 10m/18m Operating range 2) see tables Light spot diameter approx. 130mm at 6m Light source LED (modulated light) Wavelength 660nm (visible red light, polarised)

Timing Switching frequency Response time Delay before start-up

20Hz 25ms ≤ 200ms

Electrical data Operating voltage UB Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Switching power, relay Sensitivity

20 … 230VAC, 50/60Hz 20 … 230VDC ± 10% ≤ 1.5VA relay, 1 change-over contact break-contact/make-contact 250VAC/DC 250VAC, 3A/30VDC, 3A 750VA, cosϕ=1 adjustable

Operating range

1 2 3 4 5 6

TK(S) 100x100 0.3 … 8m MTK(S) 50x50 0.3 … 7m TK(S) 30x50 0.3 … 4.5m TK(S) 20x40 0.3 … 3m TK(S) 82 0.3 … 6m Tape 2 100x100 0.3 … 4m

1 2 3 4 5 6

0.1 0.1 0.1 0.1 0.1 0.1

8 4.5 4

3

4

10

7 5

8.5

6 5.5

7.5

18m models Reflectors

Indicators LED green LED yellow LED yellow flashing ready light path free light path free, no performance reserve

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals

Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied

Reflectors

-20°C … +55°C/-40°C … +55°C 1, 4 II, all-insulated IP 67, IP 69K 6) 1 (acc. to EN 60825-1) IEC 60947-5-2

Operating range

1 2 3 4 5 6

TK(S) 100x100 0.3 … 15m MTK(S) 50x50 0.3 … 11m TK(S) 30x50 0.3 … 6m TK(S) 20x40 0.3 … 5m TK(S) 82 0.3 … 11m Tape 2 100x100 0.3 … 6m

1 2 3 4 5 6

0.1 0.1 0.1 0.1 0.1 0.1

15 6 6

5

6

18

11 7.5

12

11 7.5

11.5

Operating range [m] Typ. operating range limit [m]

Options 0 … 10s (separately adjustable)

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 4=interference blanking 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test

Diagrams 10m models Typ. response behaviour (TKS 100x100) 150

Misalignment y [mm]

Switching delay (slow oper./release)

y2

100 50 0 -50 -100 -150 y1 0

2

4

6

8

10

12

Distance x [m]

18m models

Order guide

Equipment # Housing Light source

Connection Features metal plastic red light (8m) red light (15m) red light (20m) terminals M12 connector optics heating/low temperature switching delay

!

!

150

Misalignment y [mm]

Order code "

PRK 96M/R-3430-25 Part No. 500 61111

Selection table

PRK 96M/R-3420-25 Part No. 500 82066

Typ. response behaviour (TKS 100x100) 100 y2

50 0 -50 y1 -100 -150

0

5

10

15

20

Distance x [m] y2 y1

!

!

!

!

x

Remarks !

PRK 96 M/R… - 08

0603

– 39 –

Page 42

Leuze electronic PRK 96

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

10m 24m 20-230 V AC / DC

A2 LS

! Polarised retro-reflective photoelectric sensor with large operating range in visible red light ! Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application ! All-mains design 20 … 230VAC/DC with relay output ! Relay with change-over contact, sensitivity adjustment, delay before start-up and various options for optimal adaptation to the application ! Connection via comfortable terminal compartment up to 1.5mm²

We reserve the right to make changes • 96_b15e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I K

Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment

Electrical connection

UL US LISTED

IEC 60947...

IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! Spark extinction ! Reflectors ! Reflective tapes

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 40 –

PRK 96 K/R… - 08

Page 43

Leuze electronic PRK 96 Specifications

Tables 10m models

Optical data

Typ. operating range limit (TK(S) 100x100) 1) 10m/24m Operating range 2) see tables

Reflectors

Light spot diameter Light source Wavelength

1 2 3 4 5 6

TK(S) 100x100 0.3 … 8m MTK(S) 50x50 0.3 … 7m TK(S) 30x50 0.3 … 4.5m TK(S) 20x40 0.3 … 3m TK(S) 82 0.3 … 6m Tape 2 100x100 0.3 … 4m

1 2 3 4 5 6

0.1 0.1 0.1 0.1 0.1 0.1 approx. 130mm at 6m LED (modulated light) 660nm (visible red light, polarised)

Timing Switching frequency Response time Delay before start-up

20Hz 25ms ≤ 200ms

Electrical data Operating voltage UB

20 … 230VAC, 50/60Hz 20 … 230VDC ± 10% ≤ 1.5VA relay, 1 change-over contact break-contact/make-contact 250VAC/DC 250VAC, 3A/30VDC, 3A 750VA, cosϕ=1 adjustable

Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Switching power, relay Sensitivity

Indicators LED green LED yellow LED yellow flashing ready light path free light path free, no performance reserve

Mechanical data

Plastic housing

Housing Optics cover Weight Connection type polycarbonate plastic 150g terminals

Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied

-20°C … +55°C/-40°C … +55°C 1, 4 II, all-insulated IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2

Operating range

8 4.5 4

3

4

10

7 5

8.5

6 5.5

7.5

24m models Reflectors

Operating range

1 2 3 4 5 6

TK(S) 100x100 0.3 … 20m MTK(S) 50x50 0.3 … 15m TK(S) 30x50 0.3 … 10m TK(S) 20x40 0.3 … 8m TK(S) 82 0.3 … 15m Tape 2 100x100 0.3 … 10m

1 2 3 4 5 6

0.1 0.1 0.1 0.1 0.1 0.1

20 10 9

8

10

24

15 12

16

15 12

17

Operating range [m] Typ. operating range limit [m]

Options 0 … 10s (separately adjustable)

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 4=interference blanking 5) Rating voltage 250VAC

Diagrams 10m models Typ. response behaviour (TKS 100x100) 150

Misalignment y [mm]

Switching delay (slow oper./release)

y2

100 50 0 -50 -100 y1

-150

0

2

4

6

8

10

12

Distance x [m]

24m models

Order guide

Housing Light source

Connection Features metal plastic red light (8m) red light (15m) red light (20m) terminals M12 connector optics heating/low temp. switching delay UL homologation

200

Misalignment y [mm]

Equipment #

PRK 96K/R-3428-25 Part No. 500 35351

Order code "

PRK 96K/R-1430-25 Part No. 500 25168

Selection table

PRK 96K/R-1420-25 Part No. 500 25167

Typ. response behaviour (TKS 100x100) 150 y2

100 50 0 -50 -100 y1

-150 -200 0

5

10

15

20

25

30

Distance x [m]

! !

!

! !

!

! y2 y1

! !

x

Remarks !

! !

PRK 96 K/R… - 08

0603

– 41 –

Page 44

Leuze electronic PRK 96

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

0 … 1.85m 10 - 30 V DC

! Retro-reflective photoelectric sensor for safe detection of transparent media (e.g. clear glass, PE, foil) ! Reliable detection of the smallest gaps between transparent objects ! User controlled sensitivity adjustment with high resolution ! The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) ! High switching frequency for detection of fast events ! Connection via M12 connector or terminal compartment

We reserve the right to make changes • 96_b06e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I K

Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment Light/dark switching

Electrical connection

UL US LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …) ! Reflectors ! Reflective tapes ! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 42 –

PRK 96 M/P… - 06

Page 45

Leuze electronic PRK 96 Specifications

Tables

Optical data

Typ. operating range limit (TK(S) 50x50) 1) Operating range 2) Light source Wavelength

0 … 1.85m 0 … 1.5m LED (modulated light) 660nm (visible red light/polarised)

Timing Switching frequency Response time Delay before start-up

1000Hz 0.5ms ≤ 200ms

Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current Sensitivity

10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 40mA PNP transistor light/dark switching (reversible) ≥ (UB -2V)/≤ 2V max. 100mA adjustable with 10-turn potentiometer

Indicators LED green LED yellow ready clear glass - adjustment range 1 transition from quickly flashing to slowly flashing coloured glass - adjustment range 2 transition from cont. illuminated to quickly flashing other - adjustment range 3 continuously illuminated

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals or M12 connector

Diagrams

Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

-20°C … +55°C/-40°C … +55°C 1, 2, 3, 4 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test

Order guide With terminals With M12 connector

Remarks Designation

Part No.

PRK 96M/P-1830-21 PRK 96M/P-1830-41

500 28975 500 80469

PRK 96 M/P… - 06

! Integrated slit diaphragm: 3.7x20mm Objects Clear glass, PE, foil

Adjustment (indicator LED yellow) Range 1 Operating pt. 1

Coloured glass

Range 2 Operating pt. 2

Other

Range 3

0603

– 43 –

Page 46

Leuze electronic PRK 96

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

0 … 1.85m 20-230 V AC / DC

! Retro-reflective photoelectric sensor for safe detection of transparent media (e.g. clear glass, PE, foil) ! Reliable detection of the smallest gaps between transparent objects ! User controlled sensitivity adjustment with high resolution ! The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) ! All-mains design 20 … 230VAC/DC with relay output ! Connection via comfortable terminal compartment up to 1.5mm²

We reserve the right to make changes • 96_b07e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I

Indicator diode green Indicator diode yellow Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment Light/dark switching

Electrical connection

UL US LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! Spark extinction ! Reflectors ! Reflective tapes ! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 44 –

PRK 96 M/R… - 07

Page 47

Leuze electronic PRK 96 Specifications

Tables

Optical data

Typ. operating range limit (TK(S) 50x50) 1) Operating range 2) Light source Wavelength

0 … 1.85m 0 … 1.5m LED (modulated light) 660nm (visible red light/polarised)

Timing Switching frequency Response time Delay before start-up

20Hz 25ms ≤ 200ms

Electrical data Operating voltage UB Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Switching power, relay Sensitivity

20 … 230VAC, 50/60Hz 20 … 230VDC ±10% ≤ 1.5VA relay, 1 change-over contact light/dark switching (reversible) 250VAC/DC 250VAC, 3A/30VDC, 3A 750VA, cos ϕ=1 adjustable with 10-turn potentiometer

Indicators LED green LED yellow ready clear glass - adjustment range 1 transition from quickly flashing to slowly flashing coloured glass - adjustment range 2 transition from cont. illuminated to quickly flashing other - adjustment range 3 continuously illuminated

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals

Diagrams

Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied

-20°C … +55°C/-40°C … +55°C 1, 4 II, all-insulated IP 67, IP 69K 6) 1 (acc. to EN 60825-1) IEC 60947-5-2

Options Switching delay (slow oper./release)

0 … 10s (separately adjustable)

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 4=interference blanking 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test

Order guide

Remarks Designation

Part No.

PRK 96M/R-1850-25

500 80470

PRK 96 M/R… - 07

! Integrated slit diaphragm: 3.7x20mm Objects Clear glass, PE, foil

Adjustment (indicator LED yellow) Range 1 Operating pt. 1

Coloured glass

Range 2 Operating pt. 2

Other

Range 3

0603

– 45 –

Page 48

Leuze electronic PRK 96

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

0 … 8.5m 10 - 30 V DC

! Retro-reflective photoelectric sensor for safe detection of transparent media (e.g. clear glass, PE, foil) ! User controlled sensitivity adjustment with high resolution ! The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) ! High switching frequency for detection of fast events ! Connection via M12 connector or terminal compartment

We reserve the right to make changes • 96_b08e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I K

Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment Light/dark switching

Electrical connection

UL US LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …) ! Spark extinction ! Reflectors ! Reflective tapes ! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 46 –

PRK 96 M/P-1838-21 - 06 PRK 96 M/P-1838-41 - 06

Page 49

Leuze electronic PRK 96 Specifications

Tables Reflectors

Optical data

0 … 8.5m see tables LED (modulated light) 660nm (visible red light/polarised)

Timing Switching frequency Response time Delay before start-up

1000Hz 0.5ms ≤ 200ms

Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current Sensitivity

10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 40mA PNP transistor light/dark switching (reversible) ≥ (UB -2V)/≤ 2V max. 100mA adjustable with 10-turn potentiometer

Indicators LED green LED yellow ready clear glass - adjustment range 1 transition from quickly flashing to slowly flashing coloured glass - adjustment range 2 transition from cont. illuminated to quickly flashing other - adjustment range 3 continuously illuminated

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals or M12 connector -20°C … +55°C/-40°C … +55°C 1, 2, 3, 4 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test

Order guide With terminals With M12 connector

TK(S) 100x100 0 … 7m MTK(S) 50x50 0 … 6m TK(S) 30x50 0 … 4m TK(S) 20x40 0 … 3.5m TK(S) 82 0 … 5m Tape 2 100x100 0 … 3m

1 2 3 4 5 6

0.1 0.1 0.1 0.1 0.1 0.1

7 4 4 5 3.5

3.5 3

6 5

8.5 7.5

6

Operating range [m] Typ. operating range limit [m]

TK … TKS … Tape 2

= adhesive = screw type = adhesive

Diagrams Typ. response behaviour (TKS 100x100)

Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

Operating range

1 2 3 4 5 6

Misalignment y [mm]

Typ. operating range limit (TK(S) 50x50) 1) Operating range 2) Light source Wavelength

100 80 60 40 20 0 -20 -40 -60 -80 -100 0 y2 y1

2

4

6

8

10

12

Distance x [m] y2 y1 x

Remarks Designation

Part No.

PRK 96M/P-1838-21 PRK 96M/P-1838-41

500 29880 500 80760

PRK 96 M/P-1838-21 - 06 PRK 96 M/P-1838-41 - 06

Objects Clear glass, PE, foil

Adjustment (indicator LED yellow) Range 1 Operating pt. 1

Coloured glass

Range 2 Operating pt. 2

Other

Range 3

0603

– 47 –

Page 50

Leuze electronic PRK 96

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

0 … 8.5m 20-230 V AC / DC

! Retro-reflective photoelectric sensor for safe detection of transparent media (e.g. clear glass, PE, foil) ! User controlled sensitivity adjustment with high resolution ! The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) ! All-mains design 20 … 230VAC/DC with relay output ! Connection via comfortable terminal compartment up to 1.5mm²

We reserve the right to make changes • 96_b09e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I

Indicator diode green Indicator diode yellow Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment Light/dark switching

Electrical connection

UL US LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! Spark extinction ! Reflectors ! Reflective tapes ! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 48 –

PRK 96 M/R-1858-25 - 06