Page 51

Leuze electronic PRK 96 Specifications

Tables Reflectors

Optical data

0 … 8.5m see tables LED (modulated light) 660nm (visible red light/polarised)

Timing Switching frequency Response time Delay before start-up

20Hz 25ms ≤ 200ms

Electrical data Operating voltage UB Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Switching power, relay Sensitivity

20 … 230VAC; 50/60Hz 20 … 230VDC ± 10% ≤ 1.5VA relay, 1 change-over contact light/dark switching (reversible) 250VAC/DC 250VAC, 3A/30VDC, 3A 750VA, cosϕ=1 adjustable with 10-turn potentiometer

Indicators LED green LED yellow ready clear glass - adjustment range 1 transition from quickly flashing to slowly flashing coloured glass - adjustment range 2 transition from cont. illuminated to quickly flashing other - adjustment range 3 continuously illuminated

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals

TK(S) 100x100 0 … 7m MTK(S) 50x50 0 … 6m TK(S) 30x50 0 … 4m TK(S) 20x40 0 … 3.5m TK(S) 82 0 … 5m Tape 2 100x100 0 … 3m

1 2 3 4 5 6

0.1 0.1 0.1 0.1 0.1 0.1

7

3

8.5 7.5

6

Operating range [m] Typ. operating range limit [m]

TK … TKS … Tape 2

= adhesive = screw type = adhesive

Diagrams

-20°C … +55°C/-40°C … +55°C 1, 4 II, all-insulated IP 67, IP 69K 6) 1 (acc. to EN 60825-1) IEC 60947-5-2

100 80 60 40 20 0 -20 -40 -60 -80 -100 0 y2 y1

2

4

6

8

10

12

Distance x [m] y2

Options Switching delay (slow oper./release)

4 4 5 3.5

3.5

6 5

Typ. response behaviour (TKS 100x100)

Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied

Operating range

1 2 3 4 5 6

Misalignment y [mm]

Typ. operating range limit (TK(S) 50x50) 1) Operating range 2) Light source Wavelength y1

0 … 10s (separately adjustable)

x

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 4=interference blanking 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test

Order guide

Remarks Designation

Part No.

PRK 96M/R-1858-25

500 29881

PRK 96 M/R-1858-25 - 06

Objects Clear glass, PE, foil

Adjustment (indicator LED yellow) Range 1 Operating pt. 1

Coloured glass

Range 2 Operating pt. 2

Other

Range 3

0603

– 49 –

Page 52

Leuze electronic PRK 96

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

18m

! Metal housing with glass cover, protection class IP 67/IP 69K for industrial application ! Access to all sensor functions via an ASinterface without additional wiring ! Sensitivity adjustment and ready indicator for optimal adaptation to the application ! Common conductor for both power and data reduces installation work

ISO 9001

We reserve the right to make changes • 96_b10e.fm

IEC 60947...

C

A B C D E F G H

UL US LISTED

IEC 60947...

Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Device plug M12x1 Countersinking for SK nut M5, 4.2 deep Sensitivity adjustment

Electrical connection

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …) ! Spark extinction ! Reflectors and reflective tapes

AS-i Accessories: (available separately)

! Bus terminals ! AS-i ribbon cable ! Address programming device ! Coupling modules ! Intermediate cables etc. Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 50 –

PRK 96 M/A-3410-44 - 08

Page 53

Leuze electronic PRK 96 Specifications

Tables

Optical data

Reflectors

Timing

1 2 3 4 5 6

TK(S) 100x100 0.3 … 15m MTK(S) 50x50 0.3 … 11m TK(S) 30x50 0.3 … 6m TK(S) 20x40 0.3 … 5m TK(S) 82 0.3 … 11m Tape 2 100x100 0.3 … 6m

1 2 3 4 5 6

0.1 0.1 0.1 0.1 0.1 0.1

Typ. operating range limit (TK(S) 100x100) 1) 18m Operating range 2) see tables Light source LED (modulated light) Wavelength 660nm (visible red light, polarised) Sensor switching frequency Sensor response time Delay before start-up

1000Hz 0.5ms ≤ 200ms

Electrical data Operating voltage UB Bias current

26.5 … 31.6V (according to AS-i specification) ≤ 40mA per sensor

Indicators LED green LED yellow LED yellow flashing ready light path free light path free, no performance reserve

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g M12 connector

Operating range

15 6 6

5

6

18

11 7.5

12

11 7.5

11.5

Operating range [m] Typ. operating range limit [m]

Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

-20°C … +55°C/-40°C … +55°C 1, 4 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2

AS-i data for receiver

Cycle time acc. to AS-i specification AS-i standard according to profile

1 1 programmed by the user in the range of 1 to 31 (default=0) 5ms S-1.1

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 4=interference blanking 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test

Assignment: data bits Programming (host level) Ø no reflection D0 Switching output 1 reflection Ø active D1 Warning output autoControl 1 not active Ø sensor not ready D2 Ready output 1 sensor ready Ø transmitter on *D3 Activation input 1 transmitter off * default = 1

Assignment: parameter bits

System input

*P0 NC

System input

*P1 Light/dark switching

System input

*P2 NC

System output

*P3 NC

Programming (host level) Ø 1 Ø dark switching 1 light switching Ø 1 Ø 1

System parameter

Diagrams Typ. response behaviour (TKS 100x100) 150

Misalignment y [mm]

I/O code ID code Address

100

0 -50 y1 -100 -150

System parameter y2

50

0

5

System parameter System parameter

10

15

20

Distance x [m] y2 y1 x

Order guide 18m

Designation

Part No.

PRK 96M/A-3410-44

500 82067

Remarks

PRK 96 M/A-3410-44 - 08

0603

– 51 –

Page 54

Leuze electronic PRK 96

Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing

0 … 8.5m 10 - 30 V DC

A2 LS

! Retro-reflective photoelectric sensor for detection of transparent media ! Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application ! Sensitivity adjustment ! The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) ! High switching frequency for detection of fast events ! Connection via M12 connector or terminal compartment

We reserve the right to make changes • 96_b12e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I

Indicator diode green Indicator diode yellow Optical axis Device plug M12x1 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment

Electrical connection

UL US LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …) ! Reflectors ! Reflective tapes ! Alignment aid ARH 96

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 52 –

PRK 96 M/P-2838-28 (K Types) - 05 PRK 96 M/P-2838-48 (K Types) - 05

Page 55

Leuze electronic PRK 96 Specifications

Tables

Optical data

Reflectors

Timing

1 2 3 4 5 6

TK(S) 100x100 0 … 7m MTK(S) 50x50 0 … 6m TK(S) 30x50 0 … 4m TK(S) 20x40 0 … 3.5m TK(S) 82 0 … 5m Tape 2 100x100 0 … 3m

1 2 3 4 5 6

0.1 0.1 0.1 0.1 0.1 0.1

Typ. operating range limit (TK(S) 100x100) 1) 0 … 8.5m Operating range 2) see tables Light source LED (modulated light) Wavelength 660nm (visible red light/polarised) 1000Hz 0.5ms ≤ 200ms

Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current Sensitivity

10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 30mA 2 PNP transistor outputs, complementary light/dark switching ≥ (UB -2V)/≤ 2V max. 100mA adjustable with potentiometer

Indicators LED yellow LED yellow flashing light path free light path free, no performance reserve

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals or M12 connector

4 4 5 3.5

3.5 3

8.5 7.5

6

TK … TKS … Tape 2

= adhesive = screw type = adhesive

Diagrams

Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

7 6 5

Operating range [m] Typ. operating range limit [m]

Typ. response behaviour (TKS 100x100)

-20°C … +55°C/-40°C … +55°C 1, 2, 3, 4 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2

1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test

Misalignment y [mm]

Switching frequency Response time Delay before start-up

Operating range

100 80 60 40 20 0 -20 -40 -60 -80 -100 0 y2 y1

2

4

6

8

10

12

Distance x [m] y2 y1 x

Order guide With terminals With M12 connector

Remarks Designation

Part No.

PRK 96M/P-2838-28 PRK 96M/P-2838-48

500 82060 (optional)

PRK 96 M/P-2838-28 (K Types) - 05 PRK 96 M/P-2838-48 (K Types) - 05

0603

– 53 –

Page 56

Leuze electronic RT 96

Energetic diffuse reflection light scanners Dimensioned drawing

30 … 700mm 20 … 1200mm 10 - 30 V DC

A2 LS

! Robust metal housing with glass cover or plastic housing, protection class IP 67/ IP 69K for industrial application ! Sensitivity adjustment and delay before start-up for optimal adaptation to the application ! Minimal short range ! Connection via M12 connector or terminal compartment ! Multiple options with warning output, activation input, switching delays and optics heating for use at low temperatures

We reserve the right to make changes • 96_c01e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I K L

Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Device plug M12 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment

Electrical connection

UL US LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 54 –

RT 96 M/P… - 08

Page 57

Leuze electronic RT 96 Specifications Infrared light

Red light

Red light

20 … 1200mm 20 … 800mm 0 … 100% LED (modulated light) 880nm

30 … 700mm 30 … 500mm 0 … 100% LED (modulated light) 660nm

1 30 2 65 3 90

1 20 2 60 3 80

Timing Switching frequency Response time Delay before start-up

1000Hz 0.5ms ≤ 200ms

Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current Sensitivity

10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 40mA, ≤ 75mA with optics heating PNP transistor light switching ≥ (UB -2V)/≤ 2V max. 100mA adjustable

Indicators LED green LED yellow LED yellow flashing ready reflection reflection, no performance reserve

Mechanical data

Metal housing

Housing Optics cover Weight Connection type diecast zinc glass 380g terminals or M12 connector

Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

-20°C … +60°C/-40°C … +70°C 1, 2, 3, 4 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2

Options Warning output autoControl warn Optics heating Low temperature Switching delay (slow oper./release)

500 700 320 430 370 200

Infrared light

PNP transistor, 100mA, counting principle for temperature changes, prevents fogging to -35°C 0 … 10s (separately adjustable)

1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test

800 1200 950 420 290 570

1 white 90% 2 grey 18% 3 black 6% Scanning range [mm] Typ. scanning range limit [mm]

Diagrams Red light Typ. response behaviour (white 90%) 8

Misalignment y [mm]

Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light source Wavelength

6 4 y1

2 0 -2 y2

-4 -6 -8

0

100

200

300

400

500

700

600

Distance x [mm]

Infrared light Typ. response behaviour (white 90%) Misalignment y [mm]

Optical data

Tables

20 y1

15 10 5 0 -5 -10 -15 -20 y2 0

300

600

900

1200

Distance x [mm] y2 y1 x

Selection table

! The upper and lower scanning range limit varies depending on the reflection properties of the material surface. ! Short range objects are detected down to a minimum distance of 20mm.

Order code "

Equipment # Housing Light source Connection Features metal plastic red light (500mm) infrared light (800mm) terminals M12 connector optics heating/low temp. switching delay warning output short range (20mm) NPN switching output

RT 96M/P-1474-800-42 Part No. 500 41597

Remarks RT 96M/P-1374-500-42 Part No. 500 41596

Order guide

!

!

! ! !

!

! !

! ! !

RT 96 M/P… - 08

0603

– 55 –

Page 58

Leuze electronic RT 96

Energetic diffuse reflection light scanners Dimensioned drawing

20 … 1200mm 10 - 30 V DC

A2 LS

! Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application ! Complementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the application ! Minimal short range ! Connection via M12 connector or terminal compartment

We reserve the right to make changes • 96_c05e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I K L

Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Device plug M12 Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment

Electrical connection

UL US LISTED

IEC 60947...

IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …)

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 56 –

RT 96 K/P… - 08

Page 59

Leuze electronic RT 96 Specifications Optical data

Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light source Wavelength

Tables 1 20 2 60 3 80

Infrared light 20 … 1200mm 20 … 800mm 0 … 100% LED (modulated light) 880nm

1 white 90% 2 grey 18% 3 black 6%

Timing Switching frequency Response time Delay before start-up

800 1200 420 950 290 570

1000Hz 0.5ms ≤ 200ms

Scanning range [mm] Typ. scanning range limit [mm]

Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current Sensitivity

10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 40mA PNP transistor light/dark switching ≥ (UB -2V)/≤ 2V max. 100mA adjustable

Diagrams

Indicators ready reflection reflection, no performance reserve

Mechanical data

Plastic housing

Housing Optics cover Weight Connection type polycarbonate plastic 150g terminals or M12 connector

Typ. response behaviour (white 90%) Misalignment y [mm]

LED green LED yellow LED yellow flashing y1

15 10 5 0 -5 -10 -15

Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied

20

-20

-20°C … +60°C/-40°C … +70°C 1, 2, 3, 4 II, all-insulated IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2 y2 0

300

600

900

1200

Distance x [mm] y2 y1 x

1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 4) Rating voltage 250VAC

Equipment # Housing Light source Connection Features metal plastic red light (500mm) infrared light (800mm) terminals M12 connector switching delay warning output short range (20mm) NPN switching output PIN 2 = NC * PIN 4 = light/dark reversible

RT 96K/P-1444.1-800-41 Part No. 501 03585

Order code "

RT 96K/N-1444-800-46 Part No. 500 41595

! The upper and lower scanning range limit varies depending on the reflection properties of the material surface. ! Short range objects are detected down to a minimum distance of 20mm. ! * For direct connection to AS-i I/O coupling modules

RT 96K/P-1444-800-41 Part No. 500 81178

Remarks

Selection table

RT 96K/P-1444-800-21 Part No. 500 81177

Order guide

!

!

!

!

! !

!

!

!

!

!

!

!

! !

!

!

! !

RT 96 K/P… - 08

0603

– 57 –

Page 60

Leuze electronic RT 96

Energetic diffuse reflection light scanners Dimensioned drawing

20 … 1200mm 20-230 V AC / DC

A2 LS

! Robust metal housing with glass cover or plastic housing, protection class IP 67/ IP 69K for industrial application ! Relay with change-over contact, sensitivity adjustment and delay before start-up for optimal adaptation to the application ! Minimal short range ! Version with additional switching delay ! Connection via comfortable terminal compartment up to 1.5mm²

We reserve the right to make changes • 96_c02e.fm

ISO 9001

IEC 60947...

C

A B C D E F G H I K

Indicator diode green Indicator diode yellow Receiver Transmitter Optical axis Screwed cable gland M16x1.5 for Ø 5 … 10mm Countersinking for SK nut M5, 4.2 deep Connection terminals Cable entry Sensitivity adjustment

Electrical connection

UL US LISTED

IEC 60947...

IP 69K IP 67

Accessories: (available separately • see page 76)

! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! Spark extinction

Leuze electronic GmbH + Co. KG www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

– 58 –

RT 96 M/R… - 08