Page 61
Leuze electronic RT 96 Specifications
Tables
Optical data
Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light source Wavelength
20 … 1200mm 20 … 800mm 0 … 100% LED (modulated light) 880nm (infrared)
Timing Switching frequency Response time Delay before start-up
1 20 2 60 3 80
800 1200 420 950 290 570
1 white 90% 2 grey 18% 3 black 6%
20Hz 25ms ≤ 200ms
Scanning range [mm] Typ. scanning range limit [mm]
Electrical data 20 … 230VAC, 50/60Hz 20 … 230VDC ≤ 2VA relay, 1 change-over contact break-contact/make-contact 250VAC/DC 250VAC, 3A/30VDC, 3A 750VA, cosϕ=1
Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Switching power
Indicators LED green LED yellow LED yellow flashing ready reflection reflection, no performance reserve
Mechanical data
Metal housing
Housing Optics cover Weight Connection type diecast zinc glass 380g terminals
Diagrams Typ. response behaviour (white 90%) Misalignment y [mm]
Operating voltage UB
20 10 5 0 -5 -10 -15
Environmental data
-20
Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied y1
15
-20°C … +60°C/-40°C … +70°C 1, 4 II, all-insulated IP 67, IP 69K 6) 1 (acc. to EN 60825-1) IEC 60947-5-2 y2 0
300
600
900
1200
Distance x [mm] y2 y1 x
Options Switching delay (slow oper./release)
0 … 10s (separately adjustable)
1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 4=interference blanking 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test
Remarks
Selection table
! The upper and lower scanning range limit varies depending on the reflection properties of the material surface. ! Short range objects are detected down to a minimum distance of 20mm.
Order code "
Equipment # Housing Light source Connection Features metal plastic red light (500mm) infrared light (800mm) terminals switching delay short range (20mm)
RT 96M/R-1574-800-25 Part No. 500 41598
Order guide
!
! ! ! !
RT 96 M/R… - 08
0603
– 59 –
Page 62
Leuze electronic HRT 96
Diffuse reflection light scanner with background suppression Dimensioned drawing
100 … 1800mm 100 … 1200mm 10 - 30 V DC
A2 LS
We reserve the right to make changes • 96_d01e.fm
! Scanner with adjustable background suppression in visible red light or infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67/ IP 69K for industrial application ! Complementary outputs, scanning range adjustment and delay before start-up for optimal adaptation to the application ! Connection via M12 connector or terminal compartment ! Multiple options with switching delays, activation input and optics heating for use at low temperatures
ISO 9001
IEC 60947...
A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Screwed cable gland M16x1.5 for Ø 5 … 10mm H Countersinking for SK nut M5, 4.2 deep I Connection terminals K Cable entry L Scanning range adjustment Preferred entry direction for objects $ + %
Electrical connection
C UL US LISTED
IEC 60947...
IP 69K IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …)
Leuze electronic GmbH + Co. KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 60 –
HRT 96 M/P… - 09
Page 63
Leuze electronic HRT 96 Specifications
Tables
Optical data
Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light source Wavelength
Infrared light
Red light
Red light
100 … 1800mm see tables 150 … 1200mm LED (modulated light) 880nm
100 … 1200mm see tables 100 … 800mm LED (modulated light) 660nm
1 100 2 100 3 100
Infrared light 1 100 2 100 3 100
Timing Switching frequency Response time Delay before start-up
300Hz 1.67ms ≤ 200ms 10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 35mA, ≤ 75mA with optics heating PNP transistor light or dark switching (reversible) ≥ (UB -2V)/≤ 2V max. 100mA
Scanning range [mm] Typ. scanning range limit [mm]
Diagrams
Indicators
Red light
LED green LED yellow ready reflection
Mechanical data
Metal housing
Housing Optics cover Weight Connection type diecast zinc glass 380g terminals or M12 connector
Typ. response behaviour (white 90%) Misalignment y [mm]
8
Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied
-20°C … +60°C/-40°C … +70°C 1, 2, 3, 4 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2
6 4 y2
2 0 -2 y1
-4 -6 -8
0
200
400
600
800
1000 1200
Distance x [mm]
Infrared light Typ. response behaviour (white 90%)
Options for temperature changes, prevents fogging to -35°C 0 … 10s (separately adjustable)
Misalignment y [mm]
Optics heating Low temperature Switching delay (slow oper./release) Activation input activ Transmitter active/not active Activation/disable delay Input resistance
1200 1800 1600 1100 1000 1350
1 white 90% 2 grey 18% 3 black 6%
Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current
800 1200 770 1140 1050 730
≥ 8V/≤ 2V ≤ 0.5ms 47KΩ ± 10%
1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test
10 8 6 4 2 0 -2 -4 -6 -8 -10 0 y2 y1 300
600
900
1200 1500 1800
Distance x [mm] y2 y1 x
! ! !
! !
HRT 96M/N-1606-1200-27 Part No. 500 40358
!
HRT 96M/P-1620-1200-41 Part No. 500 61102
!
HRT 96M/P-1620-1200-21 Part No. 500 25114
!
HRT 96M/P-1610-1200-41 Part No. 500 25118
HRT 96M/P-1635-800-45 Part No. 501 04142
!
HRT 96M/P-1610-1200-21 Part No. 500 25116
HRT 96M/P-1640-800-41 Part No. 500 25126
Equipment # Light source red light (800mm) ! infrared light (1200mm) Connection terminals M12 connector ! Features optics heating/low temp. switching delay activation input NPN switching output for AS-i I/O coupling modules
HRT 96M/P-1640-800-21 Part No. 500 25124
Order code "
HRT 96M/P-1636-800-41 Part No. 500 32127
Selection table
HRT 96M/P-1630-800-41 Part No. 500 80047
Order guide
! !
!
! !
!
! !
!
!
! !
!
! !
! ! !
!
! !
HRT 96 M/P… - 09
Red light Typ. black/white behaviour Red. of scan range y [mm]
! With the set scanning range, a tolerance of the upper scanning range limit is possible depending on the reflection properties of the material surface. ! The diffuse reflection light scanner is also available with integrated AS-i chip for direct connection to the AS-i system.
140 A B C
120 100 80 60 40 20 0
0
200
400
600
800
1000 1200
Scanning range x [mm]
Infrared light Typ. black/white behaviour Red. of scan range y [mm]
Remarks
500 450 400 350 300 250 200 150 100 50 0
A B C
0
300
600
900
1200 1500 1800
Scanning range x [mm] A white 90% B grey 18% C black 6% y x
0603
– 61 –
Page 64
Leuze electronic HRT 96
Diffuse reflection light scanner with background suppression Dimensioned drawing
100 … 1800mm 100 … 1200mm 10 - 30 V DC
A2 LS
! Scanner with adjustable background suppression in visible red light or infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67 for industrial application ! Complementary outputs for standard applications and a wide range of input and output variants for optimum adaptation to the application ! Connection via M12 connector or terminal compartment ! Various options with switching delays, light/ dark switching, activation input, and optics heating combined with low temperature
We reserve the right to make changes • 96_d09e.fm
ISO 9001
IEC 60947...
C
A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Screwed cable gland M16x1.5 for Ø 5 … 10mm H Countersinking for SK nut M5, 4.2 deep I Connection terminals K Cable entry L Scanning range adjustment Preferred entry direction for objects $ + %
Electrical connection
UL US LISTED
IEC 60947...
IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …)
Leuze electronic GmbH + Co. KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 62 –
HRT 96 K/P… - 10
Page 65
Leuze electronic HRT 96 Specifications
Tables
Optical data
Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light source Wavelength
Infrared light
Red light
Red light
100 … 1800mm see tables 150 … 1200mm LED (modulated light) 880nm
100 … 1200mm see tables 100 … 800mm LED (modulated light) 660nm
1 100 2 100 3 100
Infrared light 1 100 2 100 3 100
Timing Switching frequency Response time Delay before start-up
300Hz 1.67ms ≤ 200ms 10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 35mA PNP transistor light or dark switching ≥ (UB -2V)/≤ 2V max. 100mA
Scanning range [mm] Typ. scanning range limit [mm]
Diagrams
Indicators
Red light
LED green LED yellow ready reflection
Mechanical data
Plastic housing
Housing Optics cover Weight Connection type polycarbonate plastic 150g terminals or M12 connector
Typ. response behaviour (white 90%) Misalignment y [mm]
8
Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied
-20°C … +60°C/-40°C … +70°C 1, 2, 3, 4 II, all-insulated IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2
6 4 y2
2 0 -2 y1
-4 -6 -8
0
200
400
600
800
1000 1200
Distance x [mm]
Infrared light Typ. response behaviour (white 90%)
0 … 10s (separately adjustable) ≥ 8V/≤ 2V ≤ 0.5ms 47KΩ ± 10%
1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking 4) Rating voltage 250VAC
Misalignment y [mm]
Options Switching delay (slow oper./release) Activation input activ (high) Transmitter active/not active Activation/disable delay Input resistance
1200 1800 1600 1100 1000 1350
1 white 90% 2 grey 18% 3 black 6%
Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current
800 1200 770 1140 1050 730
10 8 6 4 2 0 -2 -4 -6 -8 -10 0 y2 y1 300
600
900
1200 1500 1800
Distance x [mm]
Remarks y2
! ! !
!
!
!
!
!
!
!
! !
!
!
! !
! !
! !
! !
!
!
!
HRT 96 K/P… - 10
!
!
!
!
! !
Red light Typ. black/white behaviour Red. of scan range y [mm]
!
HRT 96K/P-1600.1-1200-41 Part No. 501 03217
!
HRT 96K/P-1607-1200-49 Part No. 501 03090
!
HRT 96K/P-1605-1200-45 Part No. 501 03002
HRT 96K/P-1631-800-47 Part No. 500 38471
!
HRT 96K/P-1640-800-41 Part No. 500 81464
Light source red light (800mm) infrared light (1200mm) Connection terminals M12 connector Features switching delay activation input PIN 2 = NC * PIN 4 = dark switching PIN 4 = light switching PIN 4 = light/dark reversible UL homologation
HRT 96K/P-1630-800-21 Part No. 500 80327
Equipment #
HRT 96K/P-1600-1200-41 Part No. 500 25133
Order code "
HRT 96K/P-1600-1200-21 Part No. 500 25135
Selection table
HRT 96K/P-1630-800-41 Part No. 500 80242
Order guide y1 x
140 A B C
120 100 80 60 40 20 0
0
200
400
600
800
1000 1200
Scanning range x [mm]
Infrared light Typ. black/white behaviour Red. of scan range y [mm]
! With the set scanning range, a tolerance of the upper scanning range limit is possible depending on the reflection properties of the material surface. ! The diffuse reflection light scanner is also available with integrated AS-i chip for direct connection to the AS-i system. ! * For direct connection to AS-i I/O coupling modules ! Available as a set together with cable socket
500 450 400 350 300 250 200 150 100 50 0
A B C
0
300
600
900
1200 1500 1800
Scanning range x [mm] A white 90% B grey 18% C black 6% y x
0603
– 63 –
Page 66
Leuze electronic HRT 96
Diffuse reflection light scanner with background suppression Dimensioned drawing
100 … 1800mm 20-230 V AC / DC
A2 LS
! Scanner with adjustable background suppression in infrared light ! Robust metal housing with glass cover or plastic housing, protection class IP 67/ IP 69K for industrial application ! All-mains design 20 … 230VAC/DC with relay output ! Relay with change-over contact, scanning range adjustment and delay before start-up for optimal adaptation to the application ! Connection via comfortable terminal compartment up to 1.5mm² ! Version with additional switching delay
We reserve the right to make changes • 96_d02e.fm
ISO 9001
IEC 60947...
C
A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Screwed cable gland M16x1.5 for Ø 5 … 10mm G Countersinking for SK nut M5, 4.2 deep H Connection terminals I Cable entry K Scanning range adjustment Preferred entry direction for objects $ + %
Electrical connection
UL US LISTED
IEC 60947...
IP 69K IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! Spark extinction
Leuze electronic GmbH + Co. KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 64 –
HRT 96 K/R… - 09 HRT 96 M/R… - 09
Page 67
Leuze electronic HRT 96 Specifications Optical data
Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light source Wavelength
Tables 1 100 2 100 3 100
Infrared light 100 … 1800mm see tables 150 … 1200mm LED (modulated light) 880nm (infrared)
1 white 90% 2 grey 18% 3 black 6%
Timing Switching frequency Response time Delay before start-up
1200 1800 1100 1600 1000 1350
20Hz 25ms ≤ 200ms
Scanning range [mm] Typ. scanning range limit [mm]
Electrical data Power consumption Switching output 3) Function characteristics Switching voltage, relay Switching current, relay Switching power, relay
20 … 230VAC, 50/60Hz 20 … 230VDC ≤ 1.5VA relay, 1 change-over contact break-contact/make-contact 250VAC/DC 250VAC, 3A/30VDC, 3A 750VA, cosϕ=1
Diagrams
Indicators
Typ. response behaviour (white 90%)
LED green LED yellow ready reflection
Mechanical data
Metal housing
Plastic housing
Housing Optics cover Weight Connection type diecast zinc glass 380g terminals polycarbonate plastic 150g terminals
Environmental data Ambient temp. (operation/storage) Protective circuit 4) VDE safety class 5) Protection class LED class Standards applied
Misalignment y [mm]
Operating voltage UB
-20°C … +60°C/-40°C … +70°C 1, 4 II, all-insulated IP 67, IP 69K 6) IP 67 1 (acc. to EN 60825-1) IEC 60947-5-2
10 8 6 4 2 0 -2 -4 -6 -8 -10 0 y2 y1 300
600
900
1200 1500 1800
Distance x [mm] y2 y1
Options x
0 … 10s (separately adjustable)
Typ. black/white behaviour
1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) Suitable spark extinction must be provided with inductive or capacitive loads 4) 1=transient protection, 4=interference blanking 5) Rating voltage 250VAC 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test
Red. of scan range y [mm]
Switching delay (slow oper./release)
500 450 400 350 300 250 200 150 100 50 0
A B C
0
300
600
900
1200 1500 1800
Scanning range x [mm] A white 90% B grey 18% C black 6% y
Order guide
Features
! ! ! !
HRT 96 K/R… - 09 HRT 96 M/R… - 09
!
!
! !
! !
HRT 96M/R-1689-1200-25 Part No. 500 81261
! ! !
HRT 96M/R-1690-1200-25 Part No. 500 80075
Light source Connection metal plastic infrared light (1200mm) terminals without screwed cable gland switching delay
HRT 96M/R-1680-1200-25 Part No. 500 80076
Equipment # Housing
HRT 96K/R-1690-1200-25 Part No. 500 25131
Order code "
HRT 96K/R-1680-1200-25 Part No. 500 25132 x
Selection table
! ! ! !
Remarks ! With the set scanning range, a tolerance of the upper scanning range limit is possible depending on the reflection properties of the material surface.
!
0603
– 65 –
Page 68
Leuze electronic HRT 96
Diffuse reflection light scanner with background suppression Dimensioned drawing
100 … 1800mm 100 … 1200mm
! Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application ! Access to all sensor functions via an ASinterface without additional wiring ! Scanning range adjustment and ready indicator for optimal adaptation to the application ! Common conductor for both power and data reduces installation work
We reserve the right to make changes • 96_d03e.fm
ISO 9001
IEC 60947...
C
A Indicator diode green B Indicator diode yellow C Receiver D Transmitter E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2 deep H Scanning range adjustment Preferred entry direction for objects $ + %
Electrical connection
UL US LISTED
IEC 60947...
IP 69K IP 67
Accessories: (available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) ! M12 connectors (KD …) ! Ready-made cables (K-D …)
AS-i Accessories: (available separately)
! Bus terminals ! AS-i ribbon cable ! Address programming device ! Coupling modules ! Intermediate cables etc. Leuze electronic GmbH + Co. KG www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 66 –
HRT 96M/A-1660-1200-44 - 08 HRT 96M/A-1670-800-44 - 08
Page 69
Leuze electronic HRT 96 Specifications Optical data
Typ. scanning range limit (white 90%) 1) Scanning range 2) Adjustment range Light source Wavelength
Tables Infrared
Red light
Red light
100 … 1800mm see tables 150 … 1200mm LED (modulated light) 880nm (infrared)
100 … 1200mm see tables 100 … 800mm LED (modulated light) 660nm
1 100 2 100 3 100
300Hz 1.67ms ≤ 200ms 26.5 … 31.6V (according to AS-i specification) ≤ 40mA per sensor
Scanning range [mm] Typ. scanning range limit [mm]
Indicators ready reflection
Mechanical data
Metal housing
Housing Optics cover Weight Connection type diecast zinc glass 380g M12 connector
Diagrams Red light Typ. response behaviour (white 90%) 8
Misalignment y [mm]
LED green LED yellow
Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied
-20°C … +60°C/-40°C … +70°C 1, 4 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2
4 y2
2 0 -2 y1
-4 -6 0
200
400
600
800
1000 1200
Distance x [mm]
1 1 programmed by the user in the range of 1 to 31 (default=0) 5ms S-1.1
Infrared light Typ. response behaviour (white 90%)
1) Typ. scanning range limit: max. attainable range without performance reserve 2) Scanning range: recommended range with performance reserve 3) 1=transient protection, 4=interference blanking 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test
Misalignment y [mm]
Cycle time acc. to AS-i specification AS-i standard according to profile
6
-8
AS-i data for receiver I/O code ID code Address
1200 1800 1600 1100 1000 1350
1 white 90% 2 grey 18% 3 black 6%
Electrical data Operating voltage UB Bias current
Infrared light 1 100 2 100 3 100
Timing Sensor switching frequency Sensor response time Delay before start-up
800 1200 770 1140 1050 730
10 8 6 4 2 0 -2 -4 -6 -8 -10 0 y2 y1 300
600
900
1200 1500 1800
Distance x [mm]
Programming (host level) Switching out- Ø no reflection D0 put 1 reflection Ø D1 NC 1 Ø sensor not ready D2 Ready output 1 sensor ready Ø transmitter on *D3 Activation input 1 transmitter off * default = 1
Assignment: parameter bits
System input
*P0 NC
System input
Light/dark *P1 switching
System input
*P2 NC
System output
*P3 NC
Programming (host level) Ø 1 Ø dark switching 1 light switching Ø 1 Ø 1 y2 y1
System parameter System parameter System parameter System parameter x
Red light Typ. black/white behaviour Red. of scan range y [mm]
Assignment: data bits
140 A B C
120 100 80 60 40 20 0
0
200
400
600
800
1000 1200
Scanning range x [mm]
Remarks
Infrared light
Order guide Infrared light Red light
Designation
Part No.
HRT 96M/A-1660-1200-44 HRT 96M/A-1670-800-44
500 25112 500 80048
Typ. black/white behaviour Red. of scan range y [mm]
! With the set scanning range, a tolerance of the upper scanning range limit is possible depending on the reflection properties of the material surface.
500 450 400 350 300 250 200 150 100 50 0
A B C
0
300
A white 90% B grey 18% C black 6%
HRT 96M/A-1660-1200-44 - 08 HRT 96M/A-1670-800-44 - 08
600
900
1200 1500 1800
Scanning range x [mm] y x
0603
– 67 –
Page 70
Leuze electronic HRT 96
Diffuse reflection light scanner with background suppression Dimensioned drawing
100 … 2500mm 10 - 30 V DC
We reserve the right to make changes • 96_d06e.fm
! Scanner with adjustable background suppression ! Two switching points ! Individual adaptation to applications by means of programming and diagnosis software ! Universal sensor application through optional foreground suppression or exact edge detection ! General light/dark switching or complementary switching output, scanning range adjustment and delay before start-up for optimal adaptation to the application ! Robust metal housing with glass cover, protection class IP 67/IP 69K for industrial application
ISO 9001
IEC 60947...
A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Screwed cable gland M16x1.5 for Ø 5 … 10mm H Countersinking for SK nut M5, 4.2 deep I Output with option switching delay K Connection terminals L Cable entry M Scanning range adjustment N Light/dark switching Preferred entry direction for objects $ + %
Electrical connection
C UL US LISTED
IEC 60947...
IP 69K IP 67
Accessories: Close
(available separately • see page 76)
! Mounting systems (BT 96, BT 96.1, BT 450.1-96, UMS 96) ! Programming device UPG-2, Programming software ! M12 connectors (KD …) ! Ready-made cables (K-D …)
Leuze electronic GmbH + Co. KG www.leuze.de
Remote see remarks !
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
– 68 –
HRT 96 M/P-1600-2000-42 - 05 HRT 96 M/P-3604-2000-42 - 05