4 Input / output synchronization Input synchronization Reading can be triggered by an external device (opto-coupled cell, automatic machine, electrical control device) connected to pins 5 and 6. The MaxiScan 3100 can send a message to the host system when reading is activated by an input synchronization device.
Current on
Reading is active when current flows between pins 5 and 6. It remains acti ve unti l there i s a good read or unti l the current stops flowi ng (setup option).
Current off
Readi ng i s acti ve when no current flows between pi ns 5 and 6. It remains active until there is a good read or until the current starts to flow (setup option).
Rising edge
Reading is triggered by a rising edge current between pins 5 and 6. It remains active until there is a good read or timeout (setup option).
Falling edge
Reading is triggered by a falling edge current between pins 5 and 6. It remains active until there is a good read or timeout (setup option).
Rising & falling edge
Reading is triggered by a rising or falling edge current between pins 5 and 6. It remains active until there is a good read or timeout (setup option).
Softw are
Reading is triggered when a start character is received and remains active until a stop character is received. The start and stop characters are user-programmable. This software trigger can be combined with any of the above hardware triggers. See EasySet for more details.
MaxiScan 3100 - Installation Guide
21
Page 22
4 Input / output synchronization
Example Reading triggered by an opto-coupled cell. Current provided by the external input device must be limited to 20 mA (15 mA is a good average value).
270 Ω pin 5 pin 15 pin 6 pin 10 MaxiScan 3100
22 power in sensor pin 11
MaxiScan 3100 - Installation Guide
Page 23
4 Input / output synchronization
Output synchronization An external device (switch, alarm, indicator light) can be triggered by a good read or unsuccessful read by the MaxiScan 3100. The external device is connected to pins 7 and 8.
Output trigger Good read
The output device is triggered when the MaxiScan 3100 performs a good read.
No read
The output device is triggered when the MaxiScan 3100 does not perform a good read. An input synchronization trigger is required (no read = no read before timeout).
Hardware action Current on
The output device operates when current flows between pins 7 and 8. The output device stops operating when the current stops flowing. An output trigger (good read or no read) must be activated.
Current off
The output device operates when no current flows between pins 7 and 8. The output device stops operating when the current starts to flow. An output trigger (good read or no read) must be activated.
Software action The MaxiScan sends a specified character following a good read or no read. This software output can be combined with an action (current on or current off).