The text of a manual · part 4 of 9
MaxiScan 3100 Fixed Station Scanner Installation Guide: Connections
Pages 17 to 20 of 50, from MaxiScan 3100 Fixed Station Scanner Installation Guide
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 3100
Page 17
3 Connections MaxiScan 3100 connector
SO- SO+ SI-
SI+ RTS CTS TX
RX
8
5
1
7 15
6 14
13
4 12
+5 V
3 11
2 10
9
GND 7-25 VDC
15-pin subD female connector Pin
MaxiScan 3100 - Installation Guide
Function
1
Receive data
2
Transmit data
3
Clear to send
4
Request to send
5
Positive synchronization input (SI+)
6
Negative synchronization input (SI-)
7
Positive synchronization output (SO+)
8
Negative synchronization output (SO-)
9
Not connected
10
Power in (7 to 25 VDC unregulated)
11
Ground
12
Reserved
13
Not connected
14
Not connected
15
+5 VDC out (65 mA max)
17
Page 18
3 Connections
RS-232 C connection host system power supply
RS-232 C "Y" cable P/N 0-530062-02 MaxiScan 3100
RS-232 C connection with synchronization host system RS-232 C cable MCS/host P/N 0-530062-01
MaxiScan 3100
I/O synchronization device MCS connection box P/N 0-531029-06 power supply
See the MaxiScan Connexion System section for the pinouts of the MCS connection box.
18
MaxiScan 3100 - Installation Guide
Page 19
3 Connections
RS-422 / RS-485 connection power supply user cables to connect to user application host system
MaxiScan 3100 conversion cable (RS-232 C to P/N 3-510022-00
I/O synchronization device
See the Conversion cable section for the pinouts of the RS232 C to RS-422/485 conversion cable.
Current loop connection user cable with loop to connect to application user application
MaxiScan 3100
MCS connection P/N 0-531029-06 power supply See the MaxiScan Connexion System section for the pinouts of the MCS connection box.
MaxiScan 3100 - Installation Guide
19
Page 20
3 Connections
20
MaxiScan 3100 - Installation Guide