For the Intermec 3100

Page 17

3 Connections MaxiScan 3100 connector

SO- SO+ SI-

SI+ RTS CTS TX

RX

8

5

1

7 15

6 14

13

4 12

+5 V

3 11

2 10

9

GND 7-25 VDC

15-pin subD female connector Pin

MaxiScan 3100 - Installation Guide

Function

1

Receive data

2

Transmit data

3

Clear to send

4

Request to send

5

Positive synchronization input (SI+)

6

Negative synchronization input (SI-)

7

Positive synchronization output (SO+)

8

Negative synchronization output (SO-)

9

Not connected

10

Power in (7 to 25 VDC unregulated)

11

Ground

12

Reserved

13

Not connected

14

Not connected

15

+5 VDC out (65 mA max)

17

Page 18

3 Connections

RS-232 C connection host system power supply

RS-232 C "Y" cable P/N 0-530062-02 MaxiScan 3100

RS-232 C connection with synchronization host system RS-232 C cable MCS/host P/N 0-530062-01

MaxiScan 3100

I/O synchronization device MCS connection box P/N 0-531029-06 power supply

See the MaxiScan Connexion System section for the pinouts of the MCS connection box.

18

MaxiScan 3100 - Installation Guide

Page 19

3 Connections

RS-422 / RS-485 connection power supply user cables to connect to user application host system

MaxiScan 3100 conversion cable (RS-232 C to P/N 3-510022-00

I/O synchronization device

See the Conversion cable section for the pinouts of the RS232 C to RS-422/485 conversion cable.

Current loop connection user cable with loop to connect to application user application

MaxiScan 3100

MCS connection P/N 0-531029-06 power supply See the MaxiScan Connexion System section for the pinouts of the MCS connection box.

MaxiScan 3100 - Installation Guide

19

Page 20

3 Connections

20

MaxiScan 3100 - Installation Guide