Page 25
5 Setup There are 3 different ways to set up your MaxiScan 3100 : •
Online setup with EasySet
•
Offline setup
•
Online setup with commands
EasySet System configuration software is the easiest way to set up your MaxiScan 3100. You can download your custom settings directly to the MaxiScan 3100 or print out and scan the corresponding configuration bar codes. The Basic setup section of this manual contains the barcodes to set up your MaxiScan 3100 in a basic configuration. If you want to configure your MaxiScan 3100 dynamically, or if your MaxiScan 3100 is not connected to a PC, use the slave mode to send setup commands directly to your MaxiScan 3100 (see the Slave mode section).
MaxiScan 3100 - Installation Guide
25
Page 26
5 Setup
Online setup with EasySet
➊ System power OFF
RS-232 C cable ➋ Connect (P/N : 0-530062-02)
➌ MaxiScan power ON
➍ System power ON
➎ Scan EasySet setup code
➏ Start EasySet
EasySet
➐ Set the COM port parameters to 19200 baud, 8 data bits, no parity Refer to the EasySet online help for a detailed explanation of how to use the EasySet System configuration software. You can also set up your MaxiScan 3100 offline with barcodes printed from EasySet.
26
MaxiScan 3100 - Installation Guide
Page 27
5 Setup
Basic setup You can set up your MaxiScan 3100 in a basic configuration by scanning configuration bar codes. Follow the instructions in this section. Basic setup does not include all the configuration possibilities of the MaxiScan. For a complete setup, use the EasySet System configuration software (see the Online setup with EasySet section).
➊ Connect MaxiScan power supply
➋ Reset factory defaults (optional)
➌ Select interface RS-232 C
MaxiScan 3100 - Installation Guide
27
Page 28
5 Setup
➍ Customize parameters (*) = default value (9600 baud, 7 data bits, even parity, 2 stop bits, postamble = CR + LF) 9600 baud (*)
19200 baud
7 data bits (*)
8 data bits
Odd parity
Even parity (*)
No parity
Postamble = Carriage Return
Postamble = none
Postamble = Carriage Return + Line Feed (*)
28
MaxiScan 3100 - Installation Guide
Page 29
5 Setup
➎ Disable all symbologies
➏ Select symbologies
Code 128 / EAN 128
UPC-A, UPC-E, EAN-8, EAN-13 (UPC-A -> EAN-13)
Code 39
UPC-A, UPC-E, EAN-8, EAN-13 (UPC-A -> UPC-A)
➐ Test symbologies
EAN 13
Code 39
CODE 39
01234
MaxiScan 3100 - Installation Guide
50000
Code 128
CODE 128
UPC-A
0
1234567890128
7
29
Page 30
5 Setup
30