A two-page Intermec Getting Started Guide from 1998 for the Model 200 Controller, a network controller that links Intermec data collection devices to a local area network or a host. It lists the physical, electrical and subassembly specifications and the seven setup steps, from cabling to host configuration, and points to the fuller manuals.

Device
Network controller that connects Intermec wired and wireless products to a local area network or directly to a host p. 2
Host networks
Ethernet, token ring, coaxial, twinaxial and SDLC, through local network adapter cards p. 2
Data collection networks
CrossBar through existing CrossBar controllers, the 9180 Network Controller, 2.4 GHz RF through access points, 900 MHz RF through RF controller cards (up to four 9181 Base Radio Units each) p. 2
Power
115V/60 Hz or 230V/50 Hz (switchable), 5.0-3.5 A, 250 Watts maximum p. 1
Size and weight
15.5 in x 16.0 in x 6.25 in (39.4 x 40.6 x 15.9 cm); 16.5 lbs (7.48 kg) p. 1
Environment
Operating 50°F to 122°F (10°C to 50°C); storage -4°F to 140°F (-20°C to 60°C); 0% to 85% humidity, non-condensing p. 1
Terminal emulation
VT, ANSI, 5250 and 3270 for TRAKKER Antares 2425 terminals and JANUS 900 MHz RF devices; TN5250 and TN3270 for TRAKKER Antares 2425 and JANUS 2.4 GHz RF devices p. 2
Ports
COM1, COM2, LPT1, keyboard, mouse and video ports; an optional serial I/O card adds a third serial port p. 2
Power supply outputs
250 Watts DC: +5V 22.0A, +12V 8.0A, -5V 0.5A, -12V 0.5A maximum continuous p. 1
Floppy drive
3.5-inch, 1.44MB formatted p. 1
Keyboard and mouse
Standard PC-AT 101-key keyboard; Microsoft serial mouse with PS2 connector; both ship with the controller p. 1, 2
Software
Fast Setup and Advanced Setup programs, peer-to-peer TCP/IP and APPC/LU6.2, optional Script Builder tool p. 2
Manuals
System Manual P/N 063439; Technical Reference Manual P/N 064398; this guide P/N 066048-003 p. 1

What this manual walks you through

  • Connecting the power supply, monitor, keyboard and mouse p. 2
  • Connecting the controller to the Intermec data collection network p. 2
  • Connecting the controller to the host network p. 2
  • Turning the controller on p. 2
  • Configuring the data collection environment p. 2
  • Configuring the network adapter cards and host parameters p. 2

Good to know

  • A monitor does not ship with the controller and must be obtained separately. p. 2
  • Connecting a modem or uninterruptable power supply is covered in Chapter 2 of the Model 200 Controller User Manual. p. 2

Questions this manual answers

What does the Intermec Model 200 Controller do?

It is a network controller that links Intermec wired and wireless data collection products to a local area network or directly to a host, storing and forwarding data between them. p. 1, 2

What power does the Intermec Model 200 Controller need?

115V/60 Hz or 230V/50 Hz, switchable, 250 Watts maximum. p. 1

Does the Model 200 Controller come with a monitor?

No; it ships with a 110V U.S. power cord, a keyboard and a mouse, and a monitor must be obtained separately. p. 2

Which host networks does the Model 200 Controller support?

Ethernet, token ring, coaxial, twinaxial and SDLC, using different local network adapter cards. p. 2

The file

Size and text

Pages2
PDF139 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Intermec 0200 Getting Started

The text of page 1, from the PDF itself

Physical Specifications Dimensions

Weight

15.5 in x 16.0 in x 6.25 in (39.4 cm x 40.6 cm x 15.9 cm) 16.5 lbs (7.48 kg)

Basic Electrical and Environmental Specifications Electrical rating

x115/230 V, 5,0-3,5 A,

The Model 200 Controller can:

  • send and receive messages from multiple hosts and applications.
  • store and forward data from your data collection devices to your hosts.
  • centrally manage external Intermec controllers and other data collection devices.

50-60 Hz, 250 Watts maximum

Operating temperature

50°F to 122°F (10°C to 50°C)

Storage temperature

-4°F to 140°F (-20°C to 60°C)

Relative humidity

0% to 85% (non-condensing)

Subassembly Specifications Power supply

Other Features

AC voltage/frequency: 115V/ 60 Hz; 230V/50 Hz (switchable) DC power out: 250 Watts +5V: 22.0A maximum continuous +12V: 8.0A maximum continuous

Where to Find More Information The Model 200 Controller includes online help that provides descriptions of the controller toolbars, dialog boxes, and options. The Model 200 Controller System Manual (P/N 063439) contains all the information necessary to install, configure, operate, and troubleshoot the controller.

Getting Started Guide

The Model 200 Controller Technical Reference Manual (P/N 064398) contains additional information on how transactions are routed, how the controller communicates with TCP/IP and APPC applications, how you can create script files, and how you connect the controller to your host. For information on ordering a manual, contact your local Intermec sales representative.

-5V: 0.5A maximum continuous -12V: 0.5A maximum continuous Floppy disk drive

Size: 3.5-inch Formatted capacity: 1.44MB Sides: 2 Tracks: 80 Sectors: 18 Media type: double-sided, highdensity

KeyboardStandard PC-AT 101-keyMouse

Microsoft serial, Defender, with PS2 connector

Model 200 Controller 6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 © 1998 Intermec All Rights Reserved

P/N 066048-003

Page 2 of Intermec 0200 Getting Started

The text of page 2, from the PDF itself

Congratulations on Selecting Intermec

Getting Started

to help meet your data collection needs. You have chosen the world leader in the data collection industry.

The Model 200 Controller ships with a 110V U.S. power cord, a keyboard, and a mouse. You will need to obtain a monitor. If you need another power cord, contact your local Intermec representative.

The Model 200 Controller is a network controller that connects Intermec’s wired and wireless products either to your local area network or directly to a host. Your controller has many important features that make it easy to integrate it into your data collection system.

3. Physically connect the controller to your host environment. The Model 200 Controller supports Ethernet, token ring, coaxial, twinaxial, and SDLC networks using different local network adapter cards.

1. Connect the power supply, monitor, keyboard, and mouse to your controller.

TCP/IP Host

Voltage COM1 select

⇑ Intermec’s CrossBar® network through existing CrossBar controllers. ⇑ the 9180 Network Controller.

Ethernet

COM2 IBM Host

Token Ring Coaxial Twinaxial SDLC

Note: If necessary, you can purchase a serial I/O card that provides a third serial port.

Model 200 Controller110VKEYBD200G.003 MOUSELPT1

Data Collection Network

VIDEO

T SE RE

ER LL RO NT 0 0 CO e l 2 d Mo

200G.001AC inKeyboard portMouse Video port port

2. Physically connect the controller to your Intermec data collection network. Host

The Model 200 Controller software comes with:

2.4 GHz

Power switch T2425

  • an easy-to-use Fast Setup program that uses default values to help you get the controller quickly connected to your network.

Power on indicator

RESET

⇑ peer-to-peer communications for TCP/IP and APPC/LU6.2.

J2050 JG2020 Access point

RS- 422Model 200 ControllerEthernet RS-232200G-004

CrossBar 900 MHz 9154 9181

9445 3400 J2050RS-2329189 JR2020J2010200G.0023400

⇑ straight-through VT, ANSI, 5250, and 3270 terminal emulation for TRAKKER® Antares™ 2425 terminals and JANUS 900 MHz RF devices.

  • TN5250 and TN3270 terminal emulation for TRAKKER Antares 2425 terminals and JANUS 2.4 GHz RF devices.

CONTROLLER Model 200

  • an Advanced Setup program that lets you customize the controller for your network.

6. Configure the controller for the host communications environment. That is, you need to define the parameters for the local network adapter cards in your controller. 7. Configure the controller for the host environment parameters. The Model 200 Controller supports:

4. Turn on the controller by pressing the power switch on the front panel. The Power on indicator lights and the main menu appears.

200G.005

⇑ Intermec’s 2.4 GHz RF network through access points connected to the Ethernet network. ⇑ Intermec’s 900 MHz RF network through RF controller cards. Each card supports up to four 9181 Base Radio Units.

IBM Host

Note: To connect a modem or uninterruptable power supply to your controller, see Chapter 2 in the Model 200 Controller User Manual. AC out

5. Configure the controller for the Intermec data collection environment. The Model 200 Controller supports:

⇑ an optional automated Script Builder tool that allows you to create custom terminal screens and script files for VT, ANSI, 5250, and 3270 host screens. You can run screen mapping on JANUS RF devices and TRAKKER Antares 2425 terminals.