Page 1 of H3951 & H4951 Electric Linear Servo Control System Operator's Manual

Manual · Industrial Devices

H3951 & H4951 Electric Linear Servo Control System Operator's Manual

Manual60 pagesPDF 6.4 MB

Operator's manual for the Industrial Devices H3951 and H4951 linear servo controls: setup, keypad programming, wiring and RS232 use.

Download the PDF6.4 MB

Covers · 1 model

The models it covers

Summary

What is in it

The operator's manual for the Industrial Devices H3951 and H4951 multi-position servo controls, which drive NH, RH and TH series electric cylinders. It gives five getting-started steps, the modes of operation and keypad, run mode, edit mode and system parameter command lists, a hardware reference with wiring diagrams and specifications, programming over RS232, tuning with PID gain parameters, and appendices on troubleshooting, cylinders, motors and a quick programming chart.

Its parts

  1. System Installation & Requirements
  2. Modes of Operation
  3. Run Mode Command List/Description
  4. Edit Mode Command List/Description
  5. System Parameters Command List/Description
  6. Hardware Reference
  7. Operating with RS232 Serial Communication
  8. Tuning with PID "Gain" Parameters

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

The 1993 operator's manual (P/N PCW-4436 Rev. 1.00) for the Industrial Devices H3951 and H4951 electric linear servo control systems, which drive NH, RH and TH series electric cylinders. It covers wiring, keypad and RS232 programming, specifications, mounting and a troubleshooting guide to the LCD error codes.

Read for this summary: pages 1 to 7, 45 to 48 and 55 to 57 of 60.

Device
Programmable linear servo control for electric cylinders; programs entered by keypad or RS232 p. 2, 45
Cylinders and motors
H3951: NH or RH series cylinders with the H motor (rated 160 VDC, 108 oz-in, 3600 RPM no load); H4951: TH series with the H4 motor p. 45, 56
Input power
H3951: 95 to 130 VAC at 50/60 Hz., 5 amps max; H4951: 95 to 132 VAC @ 50/60 Hz, 7.5 amps max p. 45
Motor output
H3951: 2 amps continuous, 4.5 amps peak at 160 VDC; H4951: 160 VDC @ 5 amps continuous, 7.5 amps peak; PWM MOSFET H-bridge at 20 KHz p. 45
I/O count
Twelve inputs and ten outputs, for computers, PLCs or pushbutton stations p. 4
Communications
RS232, 9600 baud, 8 data bits, no parity, 1 stop bit; three wire, no handshaking; unit address 1 to 99 p. 45, 48
Program memory
8K non-volatile EEPROM (7.5K for programs); up to 98 motion programs of up to 1000 characters each p. 45
Encoder
Dual channel TTL, 500 lines with quadrature (2000PPR), differential line driver, 5 VDC at 90ma p. 45
Logic power
12 VDC unregulated at 500 ma, 250 ma of it available for external devices p. 45
Outputs
Two SPDT relays rated 2 amps at 30 VDC or 125 VAC resistive; optically isolated NPN open collector sinking outputs, 250 ma @ 1.5VDC p. 46
Inputs
High level: optically isolated sinking or sourcing, jumper selectable AC or DC; low level: optically isolated sinking, 20 ma @ 12VDC p. 46
Operating temperature
Drive 32 F to 130 F (0 to 55 C); an internal thermostat shuts it down above 160 F (71 C) p. 45
Amplifier fuse
H3951: F2, 5 amp, 250 volt, Type ABC5; H4951: F1, 8 amp, 250 volt, Type MDA8 p. 55

What this manual walks you through

  • Getting started in five steps, from identifying components to a test program p. 4
  • Identifying system components and removing the top cover p. 6
  • Wiring motor, AC power, encoder and logic power p. 7
  • Electrical and functional specifications of inputs and outputs p. 45, 46
  • Mounting the H3951 and H4951 with the right clearances p. 47
  • Connecting and testing an RS232 link to a computer or PLC p. 48
  • Troubleshooting LCD error codes by symptom, cause and remedy p. 55
  • Cylinder models with speed and thrust, and motor data p. 56, 57

Good to know

  • If no end of travel limit switches are used, the EEOT and REOT inputs must be jumpered to ground. p. 7
  • RS-232 handshaking is not supported; some host software may need its handshaking lines jumpered. p. 48
  • Do not mount the control above heat generating equipment; keep 2 inches side and 4 inches top-bottom clearance. p. 47
  • Cylinders need the sub freezing option below 32 F and the High-Temp option above 110 F. p. 45
  • End of travel limit switches are not required but are recommended for overtravel protection. p. 6

Questions this manual answers

What does "Amplifier Fault" mean on an H3951?

A blown fuse F2, a short in the motor cable, thermal shutdown or a short in the amplifier; replace the fuse, check cabling, or remove power for 30 minutes to cool. p. 55

What are the H3951 RS232 settings?

9600 baud, 8 data bits, no parity and 1 stop bit, over three wires with no handshaking. p. 45

What power does the H3951 need?

95 to 130 VAC at 50/60 Hz, 5 amps maximum. p. 45

How many programs can the H3951 store?

Up to 98 motion programs in 8K of non-volatile EEPROM, 7.5K of it for programs. p. 45

What causes a "Motor Stalled" error?

Actual motor speed not matching the command: accel or decel too high, encoder disconnected, cylinder binding, or belt or gear slip. p. 55

The whole text · 6 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60

The file

Revision and size

RevisionP/N PCW-4436 Rev. 1.00 2/93
PublisherIndustrial Devices Corporation
Pages60
PDF6.4 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.