Page 21
| SYSTEM PARAMETERS: Alter System Parameters. Prompts the user to Enter System Parameters to alter parameter values. Press ESC to return to Run Mode.
Alter Sys Params PONCHON YES=ENTR NO=ESC DISPLAY
Reference: "Operating in System Parameters" Section in Ch. 2 for detailed operating information in this mode.
LEARN MODE: Enter Learn Mode. Prompts the user to select a program to learn positions using the Learn Mode Program Editor. Program can be 1 to 98. Press F1 to return to Run Mode.
RUN MODE FUNCTION DISPLAY
Learn Program:__
Reference: “Operating in the Learn Mode" Section in Ch. 2 for detailed operating information in this mode.
PID PARAMETERS: Prompts the user to enter PID Parameters to alter "gain" parameter values. Press ESC to return to Run Mode.
Alter PID Params BONE YES=ENTR NO=ESC DISPLAY
Reference: "Operating in PID Parameters" Sectionin Ch. 2 fordetailed, operating information in this mode.
4; DISPLAY SOFTWARE REVISION:
The LCD Screen displays the Hx957. . EEPROM Software Revision and Cylinder Model Number.
Hx951 REV 3.31 RUN MODE Model H105 FUNCTION DISPLAY
~<" the EEPROM to its original default
“| ORIGINAL CONFIGURATION: Sets state as if the control were a new unit. The buffer is cleared, all programs are erased, and all commands are set to their default values. ORIGINAL CONFIG. PON OnON YES=ENTR NO=ESC DISPLAY
ZERO POSITION: Resets the current position to zero. All absolute moves are now referenced from this point.
SET POSITION TO RONG TON ZERO ? YES-ENTR concay
TRANSMIT RS232 STRING: Tests RS232 Serial Communication setup by sending an ASCII string from the control to a Host Device connected to the RECEIVE, TRANSMIT, and GROUND terminals on the RS232 Port. The transmitted string contains the EEPROM software revision and the Cylinder Model Number Configuration for your Hx957.
ex. Hx951 REV 3.31 Model H105 (Sent to host)
RUN MODE FUNCTION DISPLAY
Sending a String over RS232
RESTORE DEFAULT VALUES: Restores all EDIT MODE, PID and SYSTEM PARAMETER commands to their default values except for the System Parameter Model Number command. This function does not modify or erase any programs.
Restore Defaults RUN MODE Yes=ENTR No=ESC FUNCTION
DISPLAY
| SYSTEM RESET: (Software Warm Boot) resets the Hx957 Software, clearing the buffer, and-resetting the control to its power up state (equivalent to cycling power). The reset cycle will disable the controller for approximately 5 seconds before entering Run Mode. (Programs and Parameter Settings are
NOT erased ) Reset System ? RON MODE Yes=ENTR No=ESC DISPLAY
O?
| JOG EXTEND: Simultaneously pressing both keys jogs the cylinder in. - the extend direction at a velocity determined by the JV System Parameters Command. When the keys are released, motion stops. The cylinder position will be shown on the LCD display at all times.
@
+XXX.Xxx 000 00 RUN MODE 14.1111 111 100 FUNCTION DISPLAY
:| JOG RETRACT: Simultaneously ~ pressing both keys jogs the cylinder in the retract direction at a velocity determined by the JV System Parameters Command. When the keys are released, motion stops. The cylinder position will be shown on the LCD display at all times.
RUN MODE FUNCTION DISPLAY
+XXx.xxx 000 00 7 11°1111 111 100
Note: For fine positioning of the actuator, momentary activation of the keypad
Reference: Seiting Jog Velocity or Jog Acceleration See System Parameters:JV (Jog Velocity) &
JA (Jog Acceleration) Commands
19
Jog Keys will move the actuator in .001 inch increments.
[|
Page 22
WHAVUGE “TF meant sw wrt strewn on Te
Command: Acceleration
Range: .05 sec to 15 sec
Syntax: F2 1
Description: Ramp time corresponding to any change of velocity from a lower speed to a higher speed. Once specified it is used in all subsequent moves until it is re-specified. (Default is .3 seconds)
EX. AC.05 DE.1 VESO DA3 GO
For an absolute move profile of 3 inches, ramp up to 50% max speed in .05 seconds.
Acceleration
Velocity (%)
-1 sec
L
3 inches
Command: Current “Hold” Limit
Range: 1 to 99
Syntax:.F2 8
Description: Current Limit setting determines the maximum allowed current draw of the motor during a move. If the CL Limit is exceeded, the current level is clamped to the CL Level for a time determined by the CT Command or until the move is completed. nnis from 1 to 99% of peak motor current where
99% = 4.5 amps for the H3951 and 7.5 amps for the H4951.
EX. CL20 CT5 DAG GO EN (for H3951)
The Current Limit for the move to absolute distance of 6 inches is set for 20% (where 20% is .9 amps (.20 x 4.5 amps)).
By controlling the motor current, the motor torque is controlled which determines the maximum linear output thrust/holding force of your cylinder.
To Determine the Linear Holding Force 41. Convert CL(%) value to a proportional current level (1); Iotor (AMPS) = CL (%) x Ipk 100% where Ipk = 4.5 amps (H Motor) Ipk = 7.5 amps (H4 Motor)
2. Convert Current (I,,,,.,) to proportional Motor Torque (T,,,,.,)
Tyrotor (02-IM)= Iyyo47 (MPS) X K, amp K, = 54 oz-in/amp (H Motor) K, = 67 02z-in/amp (H4 Motor) .
3. Calculate the Linear Output Thrust/Holding force (F,,,_...) for your cylinder F sce = ZI X Tyjotor (02-in) x Drive x Screw x Efficiency mete Ratio Pitch
Final Thrust values could vary 10%
NH and RH Cylinders - - . TH Cylinders.
Model Drive Screw Model Drive Screw Number Ratio Pitch Eff(%) Number Ratio Pitch Eff(%) 992B/102B (‘1.0 2 0.81 991B/101B 1.0 1 0.84 152B 1.5 2 0.81 151B 15 1 0.81 202B 2.0 2 0.81 201B 2.0 1 0.81 - 995B/105B 1.0 5 0.81 501B 5.0 1 0.68 155B 1.5 5 0.81 1001B 10.0 1 0.68 205B 2.0 5 0.81 994B/104B 1.0 4 0.81 355B 3.5 5 0.63 154B 1.5 4 0.81 995A/105A 1.0 5 0.36 204B 2.0 4 0.81 155A 1.5 5 0.36 5048 5.0 4 0.68 205A 2.0 5 0.36 1004B 10.0. 4 0.68 355A 3.5 5 0.28 994A106A = 1.0 6 0.28 Q98A/108A =: 1.0 8 0.36 156A 1.5 6 0.28 158A 1.5 8 0.36 206A 2.0 6 0.28 208A 2.0 8 0.36 506A 5.0 6 0.23° 358A 3.5 8 0.28 1006A 1.0 6 0.23
Note 1:The CL Command Must be used with the CT Current Hold Time Command when used in a program.
Note 2: The CL command should always be set less than the CE or CRCurrent Overload Setting) Commands in System Parameters. If this is not done, the unit will get a “Current Overload” Fault before allowing the Current Hold to initialize.
Note 3: The Current Level can be monitored (real-time) on the Hx951 LCD Display when Display Mode 2 is activated in System Parameters (DP Command).
Note 4: The Normal Servo Position Hold is NOT ACTIVE while the CL Command is active. .
Note 5: Velocity is adjusted to coincide with the programmed torque/holding force requirements.
Command: Current “Hold” Time
Range: .01 to 99999.99 seconds
Syntax: F2 7
Description: Current Time determines the amount of time the current hold is applied during a specific move once the Current "Hold" Limit is exceeded.
Note 1: The CT Command MUST be used with the CL Current Hold Limit Command within a program.
Note 2: If the move distance is completed before the CT timer expires, the move terminates normally.
Note 3: If the CT Timer expires before the Move is complete, the move is terminated and proceeds to the next stop in the program.
Note 4: The Current Hold Timer real-time count can be monitored the H3951 LCD Display when Display Mode 2 is activated System Parameters (DP Command).
EX. CL20 CT5 DA6 GO EN é
The Current Hold Time is set for 5 seconds, if the Current Hold Limit exceeded during the 6 inch absolute move, a holding _ force of 20% will be applied for 5 seconds or until the move 1S complete (whichever is first).
20 H2951/H4951 Linear Servo Controls
Page 23
\
Current Hold Feature
This feature uses the CL & CT commands simultaneously in a program. They are programmed prior to a specific Distance Command (DA or Dl) and used (once enabled) during the move to clamp the current to a set level (CL) for a set period of ime (CT). The current hold is enabled once the current level reaches the CL Limit wherein the clamp and CT Time are initiated.
Note 1: If the load and speed requirements are such that the CL value is never reached, the move is completed as though the CL command were not activated. Note 2: The Current Hold Feature can be terminated by activating a Stop on Input, a STOP/KILL via RS232 or System Input, or by pressing the ESC key. Note 3: A System Output (SO) can be defined to signal that the Current Limit has been tripped.
1. Move to a Hardstop and apply a Holding Force for a Period of Time CL CT
EX. CL25 CT15 DA10 GO DAO GO EN Hard Stop ~~ \ \ : \ DAO DA10
The program will attempt to complete a 10 inch move (DA10), if a hard stop is encountered, the current hold feature will be enabled where a holding force of 25% will be applied for 15 seconds. After this time the hold feature is disabled and the next series of program commands are executed (moving to the absolute zero (DAO) position.) If NO hard stops are encountered, the unit complete the 10 inch move and program normally.
2. Detect a Mechanical Bind or Jam in the cylinder or load during a move, once detected, terminate move, and execute the next move or command in the program.
EX. CL20 CT.1 DA6 GO DAO GO EN
The program attempts to complete a 6 inch move, if a mechanical bindjam is encountered, move is terminated after .1 sec then immediately returns to the absolute zero position. This can be used in place of the Current Overload commands (CE & CR) in System Parameters which would terminate program execution and initiate a fault state in the contro! necessitating the control to be
Command: Distance Absolute
Range: (+/-)000.000 to 999.999 inches
Syntax: F11
Description: Sets position profiles to absolute. All move distances are referenced to/from absolute zero.
Note 1: Range is (+) 0-999.999 centimeters if Metric Units are used. Enabled by System Parameter MU Command.
Ex. AC.1 DE.1 VE50 DA3 GO DAS GO VE100 DAO GO
Move to absolute position 3 inches at 50% speed, stop. Move to absolute position 5 inches at 50% speed, stop. Move to absolute position 0 inches at 100% speed, stop.
Distance Absolute
100-| -1 o sec Velocity (%) 50- 0- T T T 7 0 1 2 3 4 5
Distance (inches)
Command: Distance to a Change
Range: (+/-) 000.000 to 999.999 inches
Syntax: F13
Description: Defines a distance to change or insert a command within a move profile.
Note 1: The DC command cannot be issued prior to the DA or DI command. Note 2: A maximum of 20 DC commands may be inserted within a move profile. Note 3: The DC command is specified in absolute or incremental units depending on the initial move specification (DA or Di). When used as incremental, DC is always specified as a positive number.
Note 4: Range is (+) 0-999.999 centimeters if Metric Units are used. Enabled by System Parameter MU Command.
EX. 1 AC.05 DE.05 VE10 DA4 DC1 OT10000 DC2 OT01000 DC3 OT00100 GO
While moving to an absolute position of 4 inches turn on output 1 at 1 inch, output 2 at 2 inches and output 3 at 3 inches.
EX.2 AC.05 DE.09 VE100 DA6 DC3 VE50 GO Move to absolute position 6 inches with a-starting speed of
100%. At 3 inches, reduce speed to 50% (change on Fly) and complete move.
Distance to a change
05 09 09 “T | “ee 100-| } | = veloc alocty | | I\ I | | | | lI | ot L_| |
0 1 2 3 4 5 6 Distance (inches)
EX.3 AC.05 DE.15 VE50 DI4 DC3 VE10 GO
Ai a starting speed of 50%, begin moving an incremental distance of 4 inches. After 3 inches, ramp down to 10% speed and continue until the final position is reached.
Distance to a change
50
Velocity (%)
10-
0 4 2 Distance (inches)
21
Page 24
sop
Command: Deceleration
Range: .05 sec to 15 sec
Syntax: F22
Description: Ramp time corresponding to any change in velocity from a higher speed to a lower speed. Once specified it is used in all subsequent moves until it is re-specified. (Default .3 seconds)
EX. AC.05 DE.3 VE50 DA6 GO
Within an absolute motion profile. Ramp Down from 50% max speed to 0% speed in .3 seconds.
Deceleration | VE . 50 Velocity (%) | | 0 .05 sec .3 S@C 1 __J C 6 inches ,
Command: Distance incremental
Range: (+/-) 000.001 to 999.999 inches
Syntax: F12 ;
Description: Sets position profiles to incremental. All move distances are referenced to the starting position of each move. Note 1: Range is (+) 0-999.999 centimeters if Metric Units are used. Enabled by System Parameter MU Command .
EX. AC.1 DE.1 VE60 Di2 GO Di2 GO VE100 Di-4 GO
At 60% speed, increment 2 inches extend, stop, increment 2 more inches extend, stop, and then retract 4 inches at 100% speed.
Distance Incremental
100 - - q Velocity (%) o- Distance (inches)
Command: End Loop
Range: Not Applicable
Syntax: F25
Description: EL marks the end of a loop. Used in conjunction with the LP command which allows all commands between LP and EL to be repeated the number following LP.
EX. AC.08 DE.08 VE25 LP2 DI3 GO TD.1 EL OT10000
Execute two incremental moves of 3 inches and then turn on output 7.
Command: End of Program ~
Range: Not Applicable - Syntax: F29
Description:Program terminator which flags the end of a program.
Note: An EN command is automatically appended to the end of a program when it is saved using the ESC key.
EX. AC.05 DE.05 VE80 DAS GO EN
EN marks the end of the absolute motion program indicating a 5 inch move at 80% speed.
Command: Go Home
Range: 1 to 99
Syntax: F10
Description: This command will initiate the Homing Routine which will seek and establish the home reference position used by the control. The homing routine is executed in three stages.
Stage 1: Upon execution of the Go Home Command, the Hx957 will seek the activation of the HOME Input (J3 Pin #19) by the specified edge of the home switch. Simultaneously, the unit will initiate the home move, commanding the cylinder to seek the home switch in a specified direction at a specified speed.
GH(4+/-)nn + = extend direction _ - =retract direction 2) nn= available linear speed (%)
Stage 2: Once the input is triggered by the specified switch edge(retract or extend), the unit will ramp down and reverse direction, seeking the designated switch edge at 1% available speed.
Stage 3: When the desired edge of the switch edge is found. Velocity reduces to a creep speed and scans for the Z Marker Pulse on the encoder wherein the unit will stop motion and reset the position counter to zero. (marker pulse occurs once per revolution)
Note 1: The control will reverse direction if an End of Travel (REOT or EEOT) limit switch is encountered while searching for Home. If the second End of Travel switch is encountered in the new direction, the unit will abort the Go Home move and generate a fault condition.
Note 2: The acceleration and deceleration ramps for the Go Home move are generated by the same AC and DE Commands used in normal move profiles.
Note 3: To specify which edge of the home switch to activate the home input or to configure your home switch to be Normally Open or Normally Closed, the Home Algorithm command, HA(mn), in System Parameters is used.
HA(mn) =.01 where m=0 Retract edge m=1 Extend edge n=0 Switch/NC n=1 Switch/NO
Note: Hx951 denotes an H3951 or H4951 Control
IC
PN. 7 _ r
Page 25
Homing Routine
Exampie AC.05 DE.05 GH-20_ with HA(mn) =01
‘Yoming Program: Unit will seek home in the retract direction at
0% of the available linear speed, referencing the Reiract edge and using a Normally Open Home Switch.
Cylinder Orientation
Retract >
“(|
Hx951 Display During Homing Routine
1033
1| Going Home Home GH-+/-nn Switch 2} Low Speed Home 20 - GH Velocity (%)
Distance Reference 3| Low Speed Home Position Mark=xxxx 4| +000.000 000 00 4111111111 100
1. Stage 1: Unit seeking home in the specified direction and speed determined by GH(+/-)nn.
2. Stage 2: Home input has been triggered, unit is now approaching home at low speed from the opposite direction. (low speed = 1%)
3. Stage 3: Specified edge of home switch has activated the home input at low speed, cylinder motion reduced to creep speed and is scanning for the encoder marker pulse. The encoder count from the marker pulse is shown on the LCD Display.
4. Motor stopped and the position counter set to Zero.
Reference: Overview of Homing Profiles See System Parameters Home Algorithm (HAmn) Command
Command: GO (Execute a Move Profile)
Range: Not Applicabie
Syntax: Fi9 .
Description: Executes a move profile as defined. Execution response time is proportional to the number of commands there are to be processed in the profile to be executed.
EX. AC.05 DE.05 VE50 DI5 GO
GO initiates calculation of a move profile using buffered parameters (.05.second Accel and Decel Ramp, 50% speed, 5 inch incremental move) and then executes it. ,
Command: Load and Go
Range: 1-4
Syntax: Fi9 ; ‘ Description: Calculates a move profile in advance and waits for input n to be activated before execution. nis 1-4 user programmable input IN1, IN2, IN3 or IN4 respectively. This command allows for immediate execution of a move.
Note: *IN3 & IN4 are defined by configuring two System Inputs (SI1-S14) to be additional user programmable inputs by the SI Command (Configuration 8) in System Parameters.
If NO SI inputs are configured as additional user programmable inputs (IN) the digit assigned for IN3 or IN4.is ignored when using the GO(n) Command in a program.
EX. AC.05 DE.05 VE50 DI5 GO2
When input 2 is activated, immediate execution of the motion calculation already in the buffer is performed.
Note: Hx951 denotes an H3951 or H4951 Control
23
Page 26
WHAVLCE F LUI WIVES Wyre sew TTT
14.
\
Command: IF-THEN Range: 0,1, o0r2 yntax: F23 vescription: If the user programmable inputs match the configuration indicated by nnnn, then execute the next command in the program. If the inputs do not match, skip the next command in the program.
where IFnonn [+ Nab Acciona User Programmable inputs defined by ~ IN3I_ the Si (System Inputs) Command in System Parameters IN2 ; IN1
Note 1: ING & IN4 are defined by configuring two of the 4 System Inputs {S11-S14) to be additional user programmable inputs by the SI Command (Configuration 8) in System Parameters. If no SI inputs are configured as additional user programmable inputs (IN) the digits assigned for IN3 & IN4 are ignored when using the IF Command ina program. -
Note 2: ignore Input (N=2) should be used in the digit(s) of an “IF” statement which are being simultaneously used by a WT, GO(n), or ST(n) command or when not being used.
n=O input on (grounded) n= 1 input off (open circuit) n= 2 ignore input state
EX. LP IF0112 RN10 JF1012 RN20 IF1102 RN3O EL This program continuously loops until one of 3 inputs is activated. Activating input 1 runs Program 10, activating input 2 runs Program 20, and activating input 3 runs Program 30 (input 4 is ignored).
Note: Two System Inputs have been configured for additional User Programmable Inputs (IN3 & IN4)
/LPnnnni
Command: Loop
Range: 1 to 99999
Syntax: F2 4
Description: Used in conjunction with the EL (end loop) command. The LP command will cause all commands between LP and EL to be repeated nnnnn times. If LP is entered with no number following it or 0, the loop will be repeated continuously
Note 1: Up to 50 nested loops (one inside the other) are allowed, each LP command must have a corresponding EL command to end the loop.
Note 2: An RN command within a loop will terminate the loop and jump to a new program. EX. AC.09 DE.09 LP3 VE30 DIi GO EL VE75 DI-3 GO The actuator will perform an incremental move of 1 inch at 30% speed three times and then retract 3 inches at 75% speed.
Command: Output Command
Range: 0, 1,2
Syntax: F15
Description: Sets the 3 sinking outputs and 2 output relays on or off.
OTnnnrr is assigned as follows; n n n r r Out 2 Out3 Relay 1 Relay 2
Sets sinking output off (open collector)
Sets sinking output on (sinking to ground)
Output remains unchanged, previous state of the output is retained.
Sets relay off (contacts in inactive state) Sets relay on (contacts in active state) Relay remains unchanged, previous state of the contacts is retained. :
Note 1: Once an output is tured on, it will remain set until changed by another output command, a system reset (software warm-boot) is issued, or power is cycled.
Note 2:_All outputs are set off upon power up or during a system reset(software warm-boot).
EX. AC.05 DE.05 VE100 DA6 GO_OT10000 TD.5 OTO0000
After completing an absolute move of 6 inches, activate output 1 for .5 seconds and then turn it off.
Command: RUN Program
Range: 1-99
Syntax: F16
Description: Program number nn will be loaded into the command buffer and executed.
Note 1: This command is used within a program to start another. Upon execution, all subsequent commands in the first program are ignored while the program number following RN__ is executed. (This command acts similar to a GOTO command, NOT A GOSUB.)
Note 2: RN99 is reserved for test verification of the product. _It is stored in ROM and cannot be modified.
VE25 DI1.0 TD.5 DI-1.0 GO EN
Program 99
EX. Program 13 AC1 DE1 VES DAG GO RN1 EN Program 01 GH-30 0T10000 TD.3 OT00000 EN Executing program 13, move to absolute position 6 inches.
After the move is complete, run program 1 which commands the actuator to return home at 30% speed.
Loop
754 |
Velocity (%) 30-
= | | | |
0 1 2 3 Distance (inches)
Run Program 30 - } ~< - - | | | Velocity | | 5 - - > - E11 o 1 2 3 4 5 6 Distance (inches)
24
H2951/H4951 Linear Servo Controls
Page 27
17. 18. | TDnnnnn.nr _ Command: Stop on Input Command: Time Delay 5) Range: 0-4 Range: .01 to 99999.99 seconds 3 Syntax: F2 6 Syntax: Fi 7 Description: Stop Move Execution (or current hold) on the input Description: Time Delay between motion profiles or command specified by n, where n may be (1-4) user programmable input functions. Not valid while the motor is moving.
IN1, IN2, IN3, or IN4 respectively* Note: The time delays real time count can be shown on the Hx951 LCD Display
Note 1: IN3 & IN4 are defined by configuring two of the four System Inputs when Display Mode 2 is activated in System Parameters (DP Command). (SI1-S14) to be additional user programmable inputs by the S! Command (Configuration 8) in System Parameters. If no S! inputs are configured as EX. AC.05 DE.05 VE50 Di4 GO 0T11000 TD.5 OTOO000 i additional user programmable inputs (IN) the digit assigned for IN3 or IN4 is ignored when using the ST cammand in a program. Move 4 inches, turn outputs 1 and 2 on, delay .5 seconds, and n=0 _ Disables/turns off the STn command then turn outputs 1 and 2 off.
n = (1-4) Upon execution, the specified input is monitored during every "move profile" encountered. If the input is activated, the current "move in progress” is terminated, stopping alt motion and program execution until the input is deactivated or STO is issued. Immediately following deactivation (release) of the input, the next move profile or functional command is instantaneously executed.
Command: User Variable
Note 1: The motor is stopped upon command execution at the deceleration rate specified by the System Parameter, SDnn.nn(Stop Decel Rate: Default 0.1 ). Range: Not Applicable Note 2: Once issued, Stop on Input remains active until it is turned off by the Syntax: F20 oa 9 command, a system reset (Sofiware warn boot) is issued, or power is | Description: Allows individual Edit Mode Commands within a
. program to "prompt" the user to enter a numerical variable via EX. ST1 AC DE1 VE25 DA6 GO VES50 DAO GO EN the LCD/Keypad when executing a program.
. Note 1: User variables can be assigned to the following Edit Mode Commands;
At 25% max speed, move to absolute position 6 inches. If AC, CL, CT, DA, DC, DE, Di, LP, RN, TD, and VE. input 1 (IN1) is activated while moving, Stop Motion. When the Note 2: A single program can contain a maximum of 8 User Variables
Note 3: Variable names ONLY are saved as part of a program, variable values i i iv: , immedi he next move profile ; ; ] input Is deactivated ediatley execute the ne ep are lost if power is cycled, a system reset is issued, a program is modified, or gach time a new program is executed.
which is to move to the absolute zero position at 50% speed. (Note: If input 1.is not activated the cylinder would complete its 6 inch move before executing the absolute zero move). EX.1 AC.1 DE.1 VE10 DA_UV.POS GO EN
- For the basic absolute move profile, the absolute distance command (DA) is assigned a user variable (whose prompt is
POS). Ideal Move Profile EX.2 AC_UV_ACC DE_UV_ACC DA_UV_DIS GO DI_UV_DIS GO EN 50- | 4 | The above program string would prompt the user for two variables ACC and DIS, both of which are used multiple times Velocity | with different command. “) | _| > EX.3 AC.1 DE.1 LP10 VE_UV_VEL | | Dl2 GO EL EN Stop The above program would prompt the user once to enter in a on | | Velocity Vaiue VEL before executing a 2 inch incremental move Input 1 2 3 4 5 6 10 times.
Distance (inches)
Profile if input 1 activated at 3 inches
\ {ST (IN1)
50-4 AC DE | Velocity |
" 0 0. l
1 2 3 4 5 6 Distance (inches)
User Variable continued on following page. . . .
Note: Hx951 denotes an H3951 or H4957 Control
Page 28
User Variable Programming Entering A User Variable: A 2 Step Process 4. Assign a User Variable to an EDIT MODE COMMAND
_athe Edit Mode after entering a command, press the User Variable Key Sequence (F2 0) which will append_UV_ to the command.
xx_UV_### | [L Digit 3 Note: The User Variable H ra Command (UV) is seperated from Edit Mode Digit 2 the Edit Mode Command and the Command Digit 1 Character Code by the symbol"_"
2. Assign a Character Code for the user "Prompt"
The keypad functions are now changed to allow the user to assign a 1 to 3 character code to the user variable per the chart shown below. This character code will be displayed by the LCD when prompting the User to enter a variable during program execution.
Character KEY Character KEY Gharacter Chart 1 ABC 6 PQR
2 DEF 7 STU
3 GHI 8 VWX
4 JKL 9 YZ-
5 MNO 0 <>%
Using the right & left arrow keys will allow the user to position the cursor to 1 of the 3 digit locations. While at a location, pressing one of the listed keys (above) a specific number of times will allow you to select the desired characters. For example, pressing the "1" key will display an A in the selected character location, pressing twice will display a B, and so on. After the characters are selected, pressing the Enter Key (ENTR) will compiete the entry.
Run Time Operation of User Variables When a program is executed and a UV fuction is detected, the LCD Display will "prompt" the user to enter the desired variable.
Typical "Prompt" Enter Variable
Display XXX: Assigned 3 Cursor Character Code
Keying in the requested data and pressing Enter (ENTR) will download the information to the program.
Note 1: When a progam is executed, the Hx957 scans the program for any UV commands. If any are detected, the user is prompted to enter all the UV data PRIOR to executing any commands in the program. if multiple user variables are in a program, the UV prompts will occur in the order detected.
Note 2: User variable values can contain six digits with a decimal.
Note: Hx951 denotes an H3951 or H4951 Control
20.
’ VE100 = 12 in/sec VE50 = 6 in/sec
Command: Velocity
Range: 1 to 100%
Syntax: F1 4 ;
Description: Percentage of available speed(in/sec or cm/s) for a given move profile. Once velocity is specified, it is used in all subsequent moves until it is respecified. (Default 25%)
Note 1: Available Linear speed for a given actuator is determined by its MODEL NUMBER.
Note 2: Velocity % can represent in/s or cm/s as determined by the system parameter command MU.
EX. For an NH105B actuator execute the following program. AC.1 DE.2 VE50 DA4 GO
Move to absolute position 4 inches at 50% max speed.
NH105B Actuator If Metric Units are used Available Linear Speed = 12 in/sec = 30.48 cm/s = 15.24 cm/s
Reference : Available Linear Speeds for different actuators. See System Parameters: (MN) Model Number Command for a complete listing.
Velocity Velocity (%) . .2 eC L | r 4 inches Distance 21.
Command: Wait on Inputs
Enter Range: 0, 1, or 2
Syntax: Fi8
Description: Wait for the inputs to match the configuration indicated by nnnn before continuing execution of a program.
where WTnnnn Luna *Additional User Programmable Inputs defined by IN3 | the SI(System Inputs) Commandin System Parameters IN2 IN1
Note 1: IN3 & IN4 are defined by configuring two of the 4 System Inputs (Ssit- S/4) to be additional user programmable inputs by the Si Command (Configuration 8) in System Parameters. If no SI inputs are configured as additional user programmable inputs (IN) the digits assigned for IN3 & IN4 are ignored when using the WT Command in a program. Note 2: ignore Input (N=2) should be used in the digit(s) of an "WI" staternent which are being simultaneously used by an IF, GO(n), or ST(n) command or when not being used. n=0 input on (grounded) n= 1 input off (open circuit) n = 2 ignore input state EX. AC.07 DE.07 VE40 DA3 GO
WT0112 VE60 DA5 GO
Move to an absolute position of 3 inches. Stop and wait until the input pattern (Input 1 ON (grounded), Inputs 2 and 3 off (open circuit), and Input 4 ignored) is matched before moving to absolute position of 5 inches at 60% speed. Note: Two System Inputs have been configured for additional User Programmable inputs (IN3 & IN4)
26
Controls
Page 29
¥ BN pares
..DP. Display Mode: - Echo on/off RS232 HA ...Home Algorithm. ‘HO’. Home Offset” 2 dog Acceleration ek
SSOSNOMAWV mm (2)
: Model Number: - Current:Overload Extend
. Current Overload Retract Coordinate System -
Cylinder Motor/Mounting Configurations Rod Type Cylinder Configurations (NH & TH Series)
Parallel Reverse/Parallel Inline, NH ONLY
Rodless Cylinder Configurations (RH Series) Parallel Reverse/Parallel es
Inline
[ease |
Ye Unit Nuiiber (Device Address) : me External. Program. Select:
4. 6.
1.
Parameter: Model Number
Range: See Models Below (3 digit Code)
Description: This command configures the Hx951 control to operate with a specified cylinder’s gear ratio and screw pitch by converting the system's encoder feedback pulses into inches of linear travel. This will also determine the maximum linear speed of the actuator based on a maximum motor speed of 3600 RPM (H3951) or 2400 RPM (H4951):
NH and RH Series (Rod and Rodless): H3951 Available Linear Speeds Model Number: 3 or 4 Digit Code
STEP 1 Identify & Enter Your Cylinder 3 Digit Code Ex. Your Cylinder has this label attached tS) ELECTRIC CYLINDER | 8 NH105B-6-MS6-MTI-Z
° o E i
Label
SERIAL NUMBER © VOLTAGE
RATED CURRENT”
INDUSTRIAL DEVICES CORPORATION NOVATO, CA 9.4949
Enter 105 as your Model # (via Keypad or RS232)
Model # MN:105 VE100 = 12 in/s
Your System Parameter Display will read:
Cyl. Eng. Metric Cyl. Eng. Metric Cyl. Eng. Metric }. Model in/sec (cm/s) Model in/sec (cm/s) Model in/sec (cm/s) H102 30.0 (76.20) H105 12.0 (30.48) H108 7.5 (19.05) 152 20.0 (50.80) 155° 8.0 (20.32) 158 5.0 (12.70) 202 15.0 (38.10) 205 6.0 (15.24) 208 3.8 (9.52) 352 8.6 (21.33) 355 3.4 (864) 358 21 (5.33) 992 30.0 (76.30) 995 12.0 (30.45) 998 7.5 (9.05)
Ballscrew Acme/Ballscrew Acme
2 pitch 5 pitch 8 pitch
TH Series (Rod Type): H4951 Available Linear Speeds Model Number: 3 or 4 Digit Code
STEP 2 Identify Your Motor Mounting Configuration from the - table below. Cylinders with Reverse/Parallel mounts ONLY must denote an "R" (F2 Key) at the end of the 3 digit code when entering the System Model Number(MN).
Reverse/Parallel mounts require the conirol to reverse the motor polarity during moves so that a positive move Extends the cylinder.
Cyl. Eng. Metric Cyl Eng. Metric Cyl. Eng. Metric Model in/sec (cm/s) Model in/sec (cm/s) Model in/sec (cm/s) TH4101 40.0 (101.60) TH4104 10.0 (25.40)TH4106 6.7 (17.02)
151 27.0 (68.58) 154 6.7 (17.02) 156 4.4 (11.18) 201 20.0 (50.80) 204 5.0 (12.70) 206 3.3 (8.38) 501 8.0 (20.32) 504 2.0 (5.08) 506 1.3 (8.30) 1001 4.0 (10.16) 1004 1.0 (254) 1006 .67 (1.70) 991 40.0 (101.60) 994 10.0 (25.40) 996 67 (17.02) Ballscrew Ballscrew Acme 1 pitch 4 pitch 6 pitch
Note 1: Final move speeds are LOAD & LENGTH DEPENDENT
Note 2: Metric units for velocity are used when the MU (Metric Units) Command is enabled in System Parameters
Ex. From the previous example, the NH105B-6-MS6-MT1-Z-RM cylinder is configured with a Reverse/Parailel Motor Mount.
Specify Model Number & Reverse/Parallel Mount
Via RS232 Enter;
0 5 R Via Keypad Enter;
Note 3: The label on the Cylinder indicates the system model number and specifies the Gear Ratio and Screw Pitch.
Model # MN:105R
Your System Parameter VE100 = 12 in/s
Display will read:
Note: Hx951 denotes an H3951 or H4951 Control
27
Page 30
wesewepo ws OT wy wr or
Parameter: Current Overload & Extend
Range: 11099 ** - Description: Current Overload setting for current being drawn tion where by the motor during movement in the extend direc’ nn is from 1 to. 99% of peak motor current (99% = 4.5 amps on
H3951 and 7. 5 amps on H4951)
a ” System Parameter Display
Cur Overload Ext CE:50 Default 65%
Unit will overcurrent at 2.25A (.50x4.5 amps) in the extend direction (H3951).
Parameter: Current Overload Retract
Range: 1 to 99
Description: Current Overload setting for current being drawn by the motor during movement in the retract direction where nn is from 1 to 99% of peak motor current (99% = 4.5 amps on H3951 and 7.5 amps on H4951)
System Parameter Display
Ex. Cur Overload Ret CR:65 Default 65%
Unit will overcurrent at 4.88A (.65x7.5 amps) in the retract direction (H4951).
Parameter: Coordinate System Range: 0 or 1 Description: Defines Direction for Positive Moves.
n=0 _ Positive (+) moves extend the actuator Negative (-) moves retract the actuator n=1 Negative (-) moves extend the actuator Positive (+) moves retract the actuator
Note: Coordinate System directly affects Jog Mode Direction and the following edit mode commands; Distance Absolute(DA), Distance Incremental(Dl) and Go Home(GH).
System Parameter Display
Ex. Coordinate Sys CS:1 Default 0
\ Positive moves will Retract the cylinder & Negative moves will Extend the cylinder.
A typical application for reversing the Coordinate System is referencing the Cylinder Home Position near full Extension. All subsequent positive moves would be in the Retract direction.
28