Page 1 read from a scan by OCR; it may hold reading errors

Servo Loop Control mmand : Motor ~ Position Velocity ~ (9) - 0)

Loop Loop Amplifier PID PID |

Encoder ©

POSITION OUTPUTS RELAYS

USER SYSTEM PROGRAM HOME INPUTS INPUTS INPUTS & LIMITS

AF INPREY 8 Fo .0oP

STOP GN ELT « - CURREKT #01

CURRENT ecu or 4 it.

END OF CRGHAM REQUEST USEe yaaa:

8 Pp po |

Swen eneenigip Sage or meena et Sedementr oop ay © foved To A Larger Facility! Industrial Devices Co., LLC 3925 Cy Drive, Petaluma, CA 94954 1-800-7 77-7 89-0175 ive February 1,

Page 2 read from a scan by OCR; it may hold reading errors

Sees

5 Fa F é a

,H3951 & H4951 electric Linear Servo Control System

Operator's Manual

~

P/N PCW-4436 Rev. 1.00 2/93

* Overview System Installation & Requirements Getting Started: 5 Easy Steps Modes of Operation: Operation Flowchart Diagram Multi-Function Keypad Definitions Run Mode Command List/Description Edit Mode Command List/Description System Parameters Command List/Description Hardware Reference ¢ Operating with RS232 Serial Communication ¢ Tuning with PID "Gain" Parameters ¢ Appendices Troubleshooting: Symptom-Cause-Remedy yw Cylinders (NH, RH, & TH) ; Motors (H & H4) Quick Program Function Reference Guide Service Policy & Warranty

AD)

Page 3

This page is a scan with no text; see it in the PDF.

Page 4 read from a scan by OCR; it may hold reading errors

~ before and after moves:: Both: servo.

positioning ; coupled with the ability | to old jps can be optimized with adjustable PID t accessible to users. :

The Interface. . . , oe =: Each unit has twelve inputs and ten n outputs | whi a variety of I/O configurations, allowing the units stand alone or be easily interfaced with external devices such as computers, PLC's, or simple na ’ pushbutton operator : Stations. a

The H3951 & H4951 are powerful multi poston se controls that are: . ° Easy to program a + Easy to interface, and. “oe *Easytooperate . ..... . :

1. System Installation & Requirements 1.1 Getting Started: 5 Easy Steps

1. Identify System Components

2. Identify Control Hardware Features

3. Basic Wiring to Operate Your Control

4. Applying Power to your Unit & Identifying the Functions on the LCD Display

5. Configuring the Hx951 to your Actuator and Running a Test Program

2. Modes of Operation: Operation Fiowchart Diagram 2.1 Multi-Function Keypad Definitions 2.2 Operation Descriptions: Programming via Keypad 1. Operating in the Run Mode Running a Program 2. Operating in System Parameters Altering a System Parameter 3. Operating in PID Parameters Altering a PID Parameter 4. Operating in the Edit Mode Entering a Program: 3 Step Process Entering a NEW Program Editting an EXISTING Program 5. Operating in the Learn Mode Entering a "Learn" Program: 4 Step Process

8. Run Mode Command List/Description

4. Edit Mode Command List/Description

5. System Parameters Command List/Description

. 6. Hardware Reference ~

6.1 Functional Interface

1. LCD Display & Keypad

2. Dipswitches

3. Jumpers

4. LED Indicators

5. Fuses 6.2 Electrical Interface

1. Motor/Power interface

2. J1 Connector: I/O Interface High Level Logic

3. J2 Connector: Encoder

4. J3 Connector: /O Interface Low Level Logic 6.3 Wiring Diagrams

Fig.1 | Motor/Power Interface

Fig.2 Encoder Interface Fig.3 Logic Power Fig.4 Low Level Inputs: EOT & Home Limit Switches Low Level Inputs: Program Select Lines & User Programmable Inputs Fig.5a Activation via Pushbutton or Contact Closure Fig.5b Activation via External Sinking Device - - - - - High Level Inputs:-System Inputs Fig.6a Sinking Configuration: Activation via Pushbutton or Contact Closure Fig.6b Sinking Configuration: Activation via * External Sinking Output using External Supply Fig.6c Sinking Configuration: Activation via External Sinking Output using Internal Supply Fig.6d Sourcing Configuration: AC & DC Voltages

H38951/H4951 Linear Servo Controls

Page 5 read from a scan by OCR; it may hold reading errors

Low Level Outputs:

ee User Programmable, System, & Dedicated

9 Outputs

Fig.7a Output Terminal List

Fig.7b Output "Sinking" an External Load Circuit

Fig.7c Output Interfaced to a Sinking Input on an External Device

Fig.8 High Level Outputs: Relays 1 & 2

Fig.9 | RS232 Communication Interface: Single aan Device

Fig.10 RS232 Communication Interface: Daisy ~ Chaining

6.4 Specifications

Environmental Operational Motor/Power Interface Motors Logic Power Encoder Communications: RS232 Software/Programming Inputs: Electrical & Functional 10. Outputs: Electrical & functional 11. H3951 Dimension & Mounting Considerations 42. H4951 Dimension & Mounting Considerations

OONAAAR WAN =

7.1 Summary: RS232 Programming 7.2 Setting up RS232 Programming: 3 Steps 7.3 Software Command List

1. Edit Mode Command List

2. System Parameters Command List

3. PID Parameter Command List

4. Operational Command List eo” Operating with RS232 Serial Communication

9. Appendices Appendix A: Troubleshooting Guide: Symptom-Cause-Remedy Appendix B: H Series Cylinders: NH & RH (H3951), TH(H4951)

\ Appendix C: H Series Motors:

H Motor (H3951) H4 Motor (H4951) - Appendix D: Quick Reference Programming Chart Service Policy & Warranty

“Note. : - _‘Fhroughout this manual: any ylsting of Hx 18951 or Haast. Control:

Page 6 read from a scan by OCR; it may hold reading errors

H3951 System H4951 System Removing the Top Cover

G1 3951 Control G) 1 H4951 Control Hx951 Control @)1 NH or RH Series Electric @ 1 TH Series Eleciric

Actuator with a mounted Actuator with a mounted

H Motor H4 Motor

G) 1 Encoder: 500 line

@)) 1 Home Switch Normally Open Magnetic Position Sensor IDC Part # RPS-1 (Reed Switch) RP1 (Hall Effect)

GS) 1 3951/4951 Manual ©) 2. End of Travel "Extend and Retract" Limit Switches

Normally Closed Magnetic Position Sensors IDC Part # RPS-2 (Reed Switch) ‘ 2 Sulthle cate atthe upwards to remove. Extend and Retract End of Travel Limit Switches are Not

1 With acoin or screwdriver, turn the slot.of each of the two plastic cover screws counter- clockwise, one quarter-turn.

RP2 (Hall Effect) top cover, lift

Required for System Operation but are RECOMMENDED for Overtravel Protection.

Fuse 1 H3951 _ - Display_| v7; 2 Fuse 2 LCD Dispiay H3951 and Keypad MotorPower @ @ : Dipswitches ° | = H4951 H4951 Ac Pover = 0 2 Motor Horizontal Orientation = | USS = : {4 - Fuse 3 . . (5, Fuse 1] ° 6 / Dipswitches oT Encoder channel [FO] os Ji Connector: I/O Interface - High Level Logic d J2 Connector: Encoder interface J3. Connector: 1/O Interface - Low Level Logic Vertical Orientation Note: Hx951 denotes an H3951 or H4951 Controf 4 H8951/H4954 Linear

Page 7 read from a scan by OCR; it may hold reading errors

Figures 1-4 indicate the necessary interface wiring to operate your Hx957 Control. Wire the control and proceed to step 4.

Fig. 1 Motor/Power Interface Wiring: H3951

H39§1 Black

NH or RH Cylinder

Motor Connections

Ms __Rled (White w/QF cable) \_

_ GND Green GND _ Green

White

Line Black

CAP-

CONDOM ROD A

CAP+ a o

12220000000 z

1 1 4 ‘ 1 + 4 4 1 1 t t t 1 i i Used in high inertia or backdriving applications where ' inertia of load could cause power to be fed back into i the amplifier causing a current overload fault. ‘ ' t

1

1

‘ i t

1

1 a

1

:

t t

1

1

1

‘

' t

1

4

‘, oo

4951 Control

AC Power

Motor/Power Interface Wiring: H4951

TH Cylinder

Red (White w/QF cable)

Phoenix Connector

Dr nn

* AC Power: Unit comes with 3 conductor, 6 ft. AC line cord * Motor Connection: Unit comes with a 5 pin removable

Ch Z+ (Yellow) _

Ch Z- (Orange)

| ChB (Blue) _/ | ChAs (Red) _J | Cha- (Pink) __J

+5VDC (White) _/

| ches (Green)

GND Black) (Shield)

“BE! Encoder uses Violet as a Color Code for CHA-

GND (Black) +12V (Red)

Hx951 OF

Amplifier Chassis (Top View)

Logic Power Input

Prewired to internal Hx951 Amplifier Supply, Red and black wire supply 12 volts DC at 500 mA.

Note: The red and black internal power supply wires extend out from the lower amplifier chassis through a junction hole located below the main logic board and the J3 logic power input internal magnets.

(GND).

GND! ~ Home Home N.O. N.C. extend T Limit swi EEO mit switch NC netract REOT - End of travel a ae NC End of travel

Note 1: Home switch may be mounted anywhere along the length of the cylinder sides containing the

Note 2: If no end of travel limit switches are used, Inputs, REOT and EEOT must be jumpered to Ground

Note: Hx951 denotes an H3951 or H4951 Control

Page 8 read from a scan by OCR; it may hold reading errors

. Configuring the Hx957 to your Actuator

1. Apply Power (115VAC) to your unit.

After 2 seconds, the LCD screen will briefly flash the The System Parameter Model Number must be defined to following display, indicating the Control Type, the match the actuator being used to allow for proper operation Software EPROM Revision, and the Model Number of This command configures the Hx951 control to operate with the Cylinder in which the control is configured. a specified cylinder's gear ratio and screw pitch by convert- . ing the system's encoder feedback pulses into inches (or Control Type- - - - - [EPROM Revision cm) of linear travel. This will also determine the maximum linear speed of the actuator based on a maximum motor - Hx951 Rev. 3.31 Example speed of 3600 RPM (H3951) or 2400 RPM (H4951). Model H102 Screen, __ cylinder Mode! Cylinder Information NH and RH Series (Rod and Rodless): H3951

2. Identify functions on the RUN MODE Display Available Linear Speeds Model Number: 3 or 4 Digit Code ve . <e Cyl. Eng. Metric Cyl Eng. Metric Cyl: Eng. Metri Your unit will complete its power up cycle by entering into Model in/sec (cm/s) Model in/sec (cm/s) Model infsee (cm/s) the Run Mode. The LCD screen will enter and remain in Hi02 30.0 (76.20) H105 12.0 (30.48) Hios 75 (19 the Default Run Mode Display which indicates the 152 20.0 thee 155 8.0 fooae} 158 5.0 ter cylinder position and I/O "ON/OFF" Status. 202 15.0 (38.10) 205 6.0 (15.24) 208 3.8 (9.52) 352 86 (21.33) 355 3.4 (864) 358 21 (5.33 DEFAULT RUN MODE DISPLAY 992 30.0 (7630) 995 12.0 (30.45) 998 75 (90) OUT i User Ballscrew Acme/Ballscrew Acme Cylinder OUT2 Programmable 2 pitch i i Position, - OUT 3 Outputs pitc’ 5 pitch 8 pitch Relay 1 TH Series (Rod Type): H4951 clay Relay . . _. p Relay 2 Outputs Available Linear Speeds Model Number: 3 or 4 Digit Code, =- Cyl Eng. Metric Cyl Eng. Metric Cyl. Eng. Metric +000.000 000 00. Model in/sec (cm/s) Model in/sec (cm/s) Model in/sec (cm/s) 11.1111 111 100 TH4101 40.0: (101.60) TH4104 10.0. (25.40)TH4106 6.7 (17.02) L 151 27.0 (68.58) 154 6.7 (17.02) 156 4.4 (11.18) User ntl] |LREot 201 20.0 (50.80) 204 5.0 (12.70) 206. 3.3 (8.38) Programmable IN2 EEOT Limit Inputs 501° 8.0 (20.32) 504 2.0 (5.08) 506 1.3 (3.30) ~ “Inputs HOME 1001 4.0 (10.16) 1004 1.0 (254) 1006 .67 (1.70) Si 991 40.0 (101.60) 994 10.0 (25.40) 996 6.7 (17.02) System Si2 . | PRGS Program Ballscrew Ballscrew Acme Definable SI3 PRG2 Select 1 itch 4 pitch 6 pitch inputs = S14 PRG1 Inputs pit P pi

Cylinder Motor Mounting Configurations Rod Type Cylinder Configurations (NH & TH) Parallel Reverse/Parallel Inline

LCD Display: Functional Description

| Cylinder Position: Real-time position feedback report indicating = | Ey | cylinder position in inches or centimeters. The displayed position range is +/- 000.000 to 999.999 inches. When the internal position counter is reset, the LCD position . . . . display sets itself to zero. This condition occurs upon Rodless Cylinder Configurations (RH Series) power up, after a system reset, or completion of a Parallel Reverse/Parallel Inline \ successful homing routine., - - - ) ae | INPUTS: LCD displays Input ON/OFF Status (0 or 1) ~£

0 = Input ACTIVATED(grounded tow) 1 = Input OFF (open circuit high p (op gh) Note 1: Final move speeds are LOAD & LENGTH DEPENDENT Note 2: Metric units for velocity are used: when the MU (Metric Units) Command

1 = Output ON (Sinking to Ground) Note 3: The label on the Cylinder indicates the system model number and 0 = Output OFF(Open Circuit) specifies the Gear Ratio and Screw Pitch.

LCD displays Relay Output ON/OFF Status

(ior 0)

1 = Relay ENERGIZED (Contacts Active)

O= Sate DE-ENERGIZED (Contacts in Normal Note: Hx951 denotes an H3951 or H4951 Control tate

6 H3951/H4951 Linear Servo Controls

GF wy,

\

|

(JCI

Page 9 read from a scan by OCR; it may hold reading errors

~ Entering your M

Sdel Numberisa2$

STEP 1 Identify & Enter Your Cylinder 3 Digit Code as done in the following example. Ex. Your Cylinder has this label attached

(>) ELECTRIC CYLINDER NH205B-6-MS6-MTI-Z_- ag ° D 3 t

7 VOLTAGE RATED CURRENT

| 150V__| 3 amps |

SERIAL NUMSEB

920604

INDUSTAIAL DEVICES CORPORATION NOVATO, CA 93955

Configure the Hx957 for a Model Number 205 cylinder.

KEYPAD ENTRY

RUN MODE +000.000 000 00 Default Display 111111 111 100 Hx951 DISPLAY

F1: Enter Run Mode Function

Alter Sys Params YES=ENTR NO=ESC

Model # MN-102 This Display will VE100=30.00 in/s | a eo init is configured for.

Model # MN:205

Saving System Parameters

System Parameters have been Saved

+000.000 000 00 111111 1141 100

*To confirm your Model # Configuration Press {F1] [EDIT]

RUN MODE

Your System Parameter Display will read:

[ENTR] (in that order) Model # MN:205 VE100 = 6 in/s | L__ - .

Press [ESC] to exit back to Run Mode

Note: Hx951 denotes an H3951 or H4951 Control

STEP 2 Identify Your Motor Mounting Configuration from the table below. Cylinders with Reverse/Parallel mounts ONLY must denote an "R" (F2 Key) at the end of the 3 digit code when entering the System Model Number(MN).

Reverse/Parallel mounts require the control to reverse the motor polarity during moves So that a positive move Extends the cylinder.

Ex. From the previous example, the NH205B-6-MS6-MT1-Z-RM cylinder is configured with a Reverse/Parallel Motor Mount.

4 Specify Model Number & Reverse/Parallel Mount

Via Keypad Enter the Model Number as;

2 0 5 R-

*To confirm your Model # Configuration Press [F1j [EDIT] [ENTR] (in that order)

Model # MN:205R

Your System Parameter VE100 = 6 in/s

Display will read:

Press [ESC] to exit back to Run Mode

2. Running Test Program 99

With your control configured for the proper cylinder, you can now.test your system for proper operation by running test program 99.

Program 99 is a permanent test program in memory and cannot be erased. The program tells the cylinder to extend 1 inch, pause, and then retract 1 inch.

RUN MODE 4+000.000 000 00 Default Display 411111 111 100 KEYPAD ENTRY Hx951 DISPLAY

Fi: Enter Run Mode Function

Enter Program to Run RN:

Enter Program to Run RN:99

Your cylinder should now Extend 1 inch, pause, and then Retract 1 inch.

RUN MODE 7000.000 00000 ‘| Unit Retums to DISPLAY 411111 111 100 Foe splay

YOUR SYSTEM IS OPERATIONAL

Note: If your cylinder did not perform the above move profile REVIEW

STEPS 3-5. of this Chapter.

Page 10 read from a scan by OCR; it may hold reading errors

Operation Flowchart Diagram v | | v How to Enter How to Enter How to Enter How to Enter - "Program" "Program"

How to Exit How to Exit How to Exit

Program Execution and Operation is from the Run Mode ONLY. Programs are run via keypad, the external program select lines, or RS232.

Note: Hx951 denotes an H3951 or H4951 Control