<a>DRnn<sp> DOWNLOAD TO RAM (Memory): load a

<a>ERnn<sp>

<a>K<sp>

<a>RNnn<sp>

- <a>OC<sp>

<a>S<sp>

<a>SR<sp> aN y

<a>TD<sp> program from the host device to the Hx957 RAM Memory where nn is program number 1-98.

The DR Command initializes the beginning of a program string made up of Edit Mode Commands. To complete a program string, it MUST end with an EN command.

The programs downloaded with the DR command will NOT be saved when power is removed from the control.

The Edit Mode Commands between the DR and the EN commands do not require a device address.

The DR command is typically used in applications where the Hx957 is operated exclusively through RS232 via a Host Device which is constantly downloading NEW programs to the control.

This reduces the number of times the EEPROM is

“written” to which increases its usable life.

ERASE PROGRAM: erase the desired program, where nn is program number 1 - 98.

KILL PROGRAM: Emergency Stop, Terminate Program Execution. Immediately stops any motion, operational function, or scanning of the program select inputs currently being executed.

ORIGINAL CONFIGURATION: Resets the EEPROM to its original default state as if the control were a new unit. The buffer is cleared, all programs are erased and all commands are set to their default values.

RUN PROGRAM: Run the desired program, where nn is program number 1 - 98.

STOP PROGRAM: Stops any motion, operational function, or scanning of the program select inputs currently being executed. If a move is in progress, it will ramp down (Controlled Decel) at a rate determined by the System Parameter SD (Stop Decel Time) Command.

SOFTWARE REVISION: uploads the Hx951 EEPROM software revision level to the host device display screen. The following characters should appear on the host screen;

Hx951 REV 3.20 MODEL H205 TT I

EEPROM CYLINDER REVISION MODEL #

TELL DISTANCE: Uploads the present cylinder position from the Hx957 to the Host Device.

Ex. 1TD (+)000.000

<a>TGe<sp> .

<a>Tl<sp>

<a>TO<sp>

<a>TP<sp>

<a>ULnn<sp>

<a>ZP<sp>

<a>ZZ<sp>

TELL GAINS: Uploads the current value of the Position and Velocity Servo Loop PID Gains from the Hx957 to the Host Device.

Ex. 1TG PP10 PI3 PD5 VP10 VI5 VD5

TELL INPUTS: Uploads present status of all Logic Inputs on the Hx951. Status will be a 0 or 1 where 0=Input Activated and 1=Input Not Activated.

Ex. 1Ti 11 1111 111. 111. (atinputs inactive) eN rNOt MND WEE 22 GHOD geo 209 coo ints

TELL OUTPUTS: Uploads present status of all Logic Outputs on the Hx957. Status will be a 0 . or 1 where 0=Output On (Sinking to Ground) and 1=Output Off (Open Circuit High)

Ex. 1TO 000 00 00 000 (all outputs off) . TT TT TT TT EXE <2 58 SES Bag FF %? O58 co

TELL PARAMETERS: Uploads all System Parameters and their current values from the

Hx951 to the host device.

Ex. 1TP +, MN102 JAA Complete list CE65 JV10 of Parameters CR65 MUO and their CSO PU00 current values DP1 SD.1 sent to host EC1 S18800 display screen. HAO1 XPO HO+000.000 UNO1 |

UPLOAD: load a program from the Hx957 to the host device, where nn is program number 1 - 99. An asterisk (*) is the response if the program is blank. The final ASCII characters sent following the program are a carriage return and a line feed.

ZERO POSITION: Sets the current cylinder position to zero (+000.000).

SYSTEM RESET: resets the Hx957 Software (Warm-boot), clearing the RAM Memory (including fault states) and resetting the conirol to its power up state (equivalent to cycling power). The reset cycle will disable the controller for approximately 5 seconds before entering RUN MODE. (Programs and Parameter settings are NOT erased)

Note: Hx951 denotes an H3951 or H4951 Control

49

AD)

Page 52 read from a scan by OCR; it may hold reading errors

The H3951 & H4951 Controls, utilize encoder feedback to close servo loops to control both, velocity and position. The velocity loop is used to provide smooth and reliable speed The charts below give a graphical presentation of abasic step regulation during moves and the position loop is used to function to demonstrate the various forms of output response in@im provide accurate positioning in addition to maintaining position a servo system. These characterizations can be applied to ; before and after moves. position and velocity on the H3951 & H4951 controls when Since varying load and move conditions can alter the “actual” a en ase ecific cylinder under a given set of move system response, two sets of adjustable PID gain settings are ° available which allow the user to OPTIMIZE (tune) the system Note: The ultimate goal of the PID tuning parameters is to obtain a critically gain in order to obtain the desired response. The . damped or slightly underdamped linear positioning system, providing optimum PROPORTIONAL, INTEGRAL, and DERIVATIVE Gain terms tracking (of velocity & position) with minimum settling time. car be set for both, the Velocity and Position Servo Loops. 3 Theoretical Ideal 4 \ 5 Expected Steady State 3 Time 2 Overdamped s System recovers slowly, s appears sluggish, noticable § time to reach steady state 2 Time 2 Critically Damped 3, Typified by the minimum 5 possible rise time (fastest § response) achievable with 3 zero overshoot and zero a ringing (damped oscillations). Time . 3 Underdamped (slightly) _ = Exhibits overshoot, beginning Tuning Terms: 5 of ringing noticable settling The following reference list defines the characterization terms s time associated with Servo Tuning. é Damping: the amplitude decay of an oscillation in a system. Time Overshoot Gain: the ratio of system output to system input. 2 Ringing 8 Underdamped Hunting: the oscillation of system response about a steady ra Increased overshoot and state value due to insufficient damping. § |~« - setting Time, | ringing, longer settling time Oscillation: the periodic variation in the magnitude of velocity é or position about a specified reference level or setpoint. Time Overshoot: the maximum deviation between the move velocity 2 \ or position with the expected steady state value. s Oscillatory 5 Hunting about the setpoint Ringing: a dampened oscillation in a system which results 5 from a sudden change of state. 3 a Rise Time: the time required for a signal to rise from 10% of its . Time final value to 90% of its final value. Servo: Closed loop system using feedback to regulate an > output signal based on the amount of error in the system. 8 {\ Oscillatory $ Unstable, uncontrollable Settling Time: the time required for a controiled output 5 operation (position or velocity) to achieve its commanded steady state 2 level when experiencing a damped oscillation. & Time

Page 53 read from a scan by OCR; it may hold reading errors

Velocity and Position Loops

Velocity Loop P 1D The following flowchart is offered as a guide to optimize your __f Pominates ieee H3951/H4951 system (by visually observing the cylinder 7 7 "position" servo response). J Fosition Loop PID i ominates Note 1: When tuning is required for an H3951 or H4951 System, most applications will involve tuning the Position Loop Gains ONLY. Velocity Loop Gains will often NOT have to be adjusted unless certain conditions exist where ff there is noticeable ringing {in velocity) near the acceleration/constant velocity f breakpoint (review the following page for info on VP, VI & VD).

Velochy 1 a ' ae Time Note 2: It is recommended to "individually" obtain the optimum gain settings for =, . various sets of move and load conditions which will occur during "actual" system Typical Move Profile . operation. It may be necessary to compare these settings and compromise, on values (gains & move parameters) to maintain stability through the entire range of operating conditions.

For the H3951.& H4951 Systems, the velocity loop dominates the acceleration and constant velocity portions ofthe move. profile to provide smooth and reliable speed regulation.

During the deceleration portion of a move, dynamic control Preset Position Loop Gains shifts to the position loop which is first used to obtain accurate | Under Pp2 Pit PDI positioning and then used to maintain the final, steady state conditions, ¥. Increase PP Execute Move + 10-18% (2 oF 3)

position. _ a

Completing

Press [Esc i Move? Key fo

(to exit program)

In most applications tuning will not be required because of the mechanical reduction offered by the electric cylinders between the motor and the load. However, some applications will require PID tuning to "adapt" the servo response to the given set of load and move conditions.

; ‘Actual PID tuning is an iterative process whose affect on an oaxcessive™ N ) output response is measured in terms of Overshoot, Ringing, & Oscillation? ” . ‘etiling time. Since PID gain parameters are interactive, Knowing how each affects your output response is important when attempting to tune your system. . . Reduce PP ee ro 10-15% (2 or 3) ‘era z Increase PI 5-10% (1 or 2) ¥ Execute Move Excessive N Ringing or Oscillation? This should, _p dampen ringi increase PD by created by Pl. 10% (2) Increase PI by Reduced P! b 5% (1) s%(1) ‘ ry Execute Move : v NAaii “ameter: Excessive “PID "Gain Parameter: Ringing or S~. ; Range Oscillation? Parameter Description of Values Default ¢ PP Position - Proportional Gain (0-20) 10 >| Position - Integral Gain (0-20) 10 PD Position - Derivative Gain (0-20) 10 Rey VP Velocity - Proportional Gain (0-20) 10

Vi Velocity - Integra!l Gain (0-20) 10 VD Velocity - Derivative Gain (0-20), =10 Cen

51 q

Page 54 read from a scan by OCR; it may hold reading errors

woewew=- - - - Whip ews

Parameter: Position Loop - Proportional Gain

Range: 0-20

Description: The Proportional Gain (or Sensitivity) provides a restoring force in a system which reacts to the amount of following or tracking error in position (typically due to load variations).

Note 1: The force is proportional to the amount of error, increasing linearly as the position error increases. It is indicative of the “stiffness” of a system, counteracting any "non-commanded" changes in position.

Too Low: Overdamped System, recovers too slowly (slow response), appearing sluggish, may undershoot and not complete move.

Too High: system recovers too quickly, causing overshoot, ringing, and oscillation.

PID Parameter Display

Enter Position P Gain PP:10

EX.

Default 10

Parameter: Position Loop - integral Gain

Range: 0-20

Description: The Integral Gain (or reset) provides a corrective force during steady state conditions where position following error (or drift) is eliminated over time.

Note 1: In attempting to Reduce the Steady State position error (drift) over time, the force created is proportional to the amount of error, increasing linearly with time.

Note 2: Typically set to the smallest (value compromised by overshoot, settling time, and response time.

Too Low: "Thud" response, may not achieve final position.

Too High: Increases overshoot and ringing, cylinder may "hunt" about the set position, may also cause oscillation.

PID Parameter Display EX. ‘Enter Position 1 Gain PI:10 © Default 10

Parameter: Position Loop - Derivative Gain Range: 0-20 Description: The Derivative Gain is a differential term which reacts to the changes in the rate of position error, providing a damping force to eliminate oscillation, minimize overshoot and ringing, and to stabilize the system.

Note 1: The damping force provided by the derivative term it is proportional to the rate of change of the position error. Note 2: Basic function is to act as “shock absorber” or transient dampener with regards to position.

Too Low: Overdamped response

Too High: Creates excessive ringing and settling time, may cause oscillation. ‘

PID Parameter Display

Enter Position D Gain PD:10

EX.

Default 10

Parameter: Velocity Loop - Proportional Gain

Range: 0-20 ; Description: The Proportional Gain (or Sensitivity) provides a restoring force in a system which reacts to the amount of following or tracking error in velocity (typically due to load variations). ;

Note 1: The force is proportional to the amount of error, increasing linearly as the velocity error increases. It is indicative of the “stiffness” of a system, counteracting any “non-commanded” changes in velocity.

Too Low: Overdamped System, recovers too slowly (slow response), appearing sluggish, may undershoot and not complete move.

Too High: System Recovers too quickly, creating a "hard" move response, may cause overshoot, ringing, and oscillation.

PID Parameter Display

Enter Position P Gain VP:10

EX.

Default 1

Parameter: Velocity Loop - integral Gain

Range: 0-20

Description: The Integral Gain (or reset) provides a corrective force during steady state conditions where veldcity following error (or drift) is eliminated over time. Note 1: In attempting to Reduce the Steady State velocity error (drift) over time, the force created is proportional to the amount of error, increasing linearly with time.

Note 2: Typically set to the smallest value compromised by overshoot, settling time, and response time.

Too Low: Cylinder may not achieve final "constant velocity value” -

Too High: Increases overshoot & ringing, cylinder may hunt about the set velocity.

PID Parameter Display EX. Enier Velocity . 1 Gain V1:10 Default 10

Parameter: Velocity Loop - Derivative Gain

Range: 0-20

Description: The Derivative Gain is a differential term which reacts to the changes in the rate of velocity error, providing a damping force to eliminate oscillation, minimize overshoot and ringing, and to stabilize the system.

Note 1: The damping force provided by the derivative term, it is proportional to the rate of change of the error.

Note 2: Basic function is to act as "shock absorber" or transient dampener with regards to velocity.

Too Low: Overdamped response Too High: Creates ringing and oscillation.

PID Parameter Display

Enter Velocity D Gain VD:10

EX. Default 10

52

Page 55 read from a scan by OCR; it may hold reading errors

Chapter 9 Appendices symptom

Cause

Remedy

"Amplifier Fault" (Error Code on LCD Display)

1. Fuse F2 Blown (H3951) Fuse F1 Blown (H4951)

2. Short in motor cable _ Thermal Shutdown (Amplifier exceeded internal termperature limits, 160F)

3. Remove Power from

1. Replace Fuse

H3951: 5 amp, 250 volt, Type ABC5

4951: 8 amp, 250 volt, Type MDA8 . Check motor cabling Control for 30 minutes, then Reapply Power. Have good air circulation through the drive heatsink & verify duty cycle limits of cylinder/motor

~ 4. Short detected in amplifier 4. Return to IDC for Repair "Current Overload" 1. Cylinder/Load Binding 1. Check unloaded Cylinder Operation and (Error Code on LCD Display) mechanical mounting of load 2. Cylinder Rammed into Physical End of 2. Reverse Direction of Motion Travel 3. Velocity set too high for given load 3. Reduce VE setting 4. Accel or Decel Rate set too high for 4. Increase AC or DE Time Setting (this given load reduces the Rate) 5. Current Limit Settings too low for given 5. increase Current Limit Settings CE & CR move in System Parameters

“EEPROM CheckSum Error*, _

~ Data in EEPROM Corrupted

1. Reformat EEPROM

Press keys in order {not simultaneously)

(Error Code on LCD Display) [| . Reformat (All Programs ERASED/Parameters Reset) 2. Anerror or malfunction has been 2. Replace EEPROM detected in the control EEPROM chip. "Encoder Fault" {. Encoder Signal is faulty 4. Check Encoder wiring to control (Error Code on LCD Display) 2. Move attempted and Motor NOT 2. Verify Motor Connections Connected 3. Replace Encoder 3, Defective Encoder "Error Finding Home" 4. Homing Routine was NOT successfully 4. Check for proper operation of Home (Error Code on LCD Display) completed where both “end of travel Switch and verify signal connections to fimits" were reached without detecting the Home Input. any Home Input or the home input did not change state during the third stage of the homing routine. ° "Hit a Limit" 4. An Extend (EEOT) or Retract (REOT), 1. Check for End of Travel Limit Switch (Error Code on LCD Display) Normaily Closed "End of Travel" Activaton or check EEOT and REOT

Connection to Ground (GND) is broken (open circuit).

connections for a loose or broken wire.

2. No power on the logic supply inputs 21 2. Check for loose or broken connection on (PWR) and 22 (GND). terminals 21 and 22 or verify fuse F1 . (H3951) or F3 (H4951) is good. "Motor Stalled” "This fault occurs when the "Speed" error (Error Code on LCD Display) bandwidth has been exceeded wherein the actual motor speed (indicated by encoder feedback) does not match the commanded motor speed. This condition can occur during the following; 1. Accel/Decel Rates too high for given 1. Increase AC or DE Time Setting (this load reduces the Rate) 2. Encoder Disconnected/Miswired 2. Check Encoder Connections 3. Cylinder/Load Binding 3. Check unloaded Cylinder Operation and mechanical mounting of load. 4. Belt or Gear Slip 4. Tighten Belt/Pulley or Gear _ Gajbled Charactersin-CD- Data in EEPROM Corrupted, - F Felomat EEPROM Display Press keys in order (not simultaneously) (All Programs ERASED/Parameters

Reset)

Continuous Creep Speed during Home Routine

{. Control Cannot Detect Z Marker Pulse of Encoder during Final Stage of Homing Routine

1. Replace Encoder

53

® a

Page 56 read from a scan by OCR; it may hold reading errors

NH and RH Series (used with H3951)

TH Series (used with H4951)

Model* Drive Screw Max Speed Max Thrust Model* Drive Screw Max Speed Max Thrust Number Ratio Pitch Eff(%) @NOLoad (Ibs) Number Ratio Pitch | Eff(%) @NOLoad (Ibs) 992B/102B 1.0 2 0.81 30.0 135 991B/i01B 1.0 4 0.81 40.0 120 152B 1.5 2 0.81 20.0 200 151B 15 1 0.81 27.0 180 202B 2.0 2 0.81 15.0 270 201B 2.0 1 0.81 20.0 260 995B/105B 1.0 5 0.81 12.0 350 501B 5.0 1 0.68 8.0 540 155B 1.5 5 0.81 8.0 550 1001B 10.0 1 0.68 4.0 1080 205B 2.0 5 0.81. 6.0 700 994B/104B 1.0 4 - 0.81 10.0 480 355B 3.5 5 0.63 3.4 800 154B 1.5 4 0.81 6.7 720 Q995A/105A 1.0 5 0.36 12.0 150 204B 20 4 0.81 5.0 1040 155A 15 5 0.36 8.0 220 504B 5.0 4 0.68 2.0 2160 205A 2.0 5 0.36 6.0 290 1004B 10.0 4 0.68 1.0 2400 355A 3.5 5. 0.28 3.4 500 994A/106A 1.0 6 "0.28 6.7 280 - 998A/108A 1.0 8 0.36 75 240 156A 15 6 0.28 4.4 440 158A 1.5 8 0.36 5.0 360 206A . 2.0 6 0.28 . 3.3 640 208A 2.0 8 0.36 3.8 475 506A 5.0 6 0.23 "1.3 - 4330 358A 3.5 8 0.28 2.1 800 1006A 1.0 6 0.23 0.67 2400 *A=Acme, B = Ball screw *A=Acme, B = Ball screw

Note 1: Final move speeds are LEN DEPENDENT Note 1: Final move speeds are LOAD AND LENGTH DEPENDENT

Note 2: Max thrust values are also LENGTH DEPENDENT

Note 2: Max thrust values are also LENGTH DEPENDENT

Rod Type Cylinder Configurations (NH Series)

Parallel Reverse/Parallel Inline

FS = > Ef

Rodless Cylinder Configurations (RH Series) Inline

Reverse/Paralle!

Parallel

= _

Rod Type Cylinder Configurations (TH Series)

Parallel Inline eS, .

Ej | i+

D

-3951/H4951 Linear Serve Controls

Page 57 read from a scan by OCR; it may hold reading errors

H Motor Used on NH & RH Cylinders with the H4 Motor Used on TH Cylinders with the H4951 H3951 Control Control Operational: Permanent Magnet 2 Pole DC Motor, Operational: Permanent Magnet 2 Pole DC Motor, 2 Lead 2 Lead Voltage: Rated 160 VDC, 180 VDC max Voltage: Rated 160 VDC, 180 VDC max Current: 2.0 amps continuous, 6 amps peak Current: 5 amps continuous,7.50 amps peak _ Torque: 108 oz-in Torque: 335 oz-in _ NoLoad Speed: 3600 RPM No Load Speed: 2400 RPM + Torque Constant: 54 oz/in amp Torque Constant: 67 oz/in amp Moment of Inertia: .034 oz-in-sec? Moment of Inertia: .20 oz-in-sec? Windings , Windings Resistance: 6.4 ohms Resistance: 1.5 ohms Inductance: 21mh Inductance: 42mh Cabling: Less than 50ft (16AWG), Cabling: Less than 50ft (16AWG), . 50-100ft (144AWG), 100-200ft (10AWG) _50-100ft (14AWG), 100-200ft (10AWG) Brushlife: 5 Million Cycles, 5000 Hours Brushlife: 5 Million Cycles, 5000 Hours 0.2500 ws tae Sw seas a) R . ome 1.00 ee SS 7 ~| RB seal (12.7) dia . te 159 F [AA + fae 0.3125 cae d Dia both ends - 013120 (7.92 = 0.75 (19.1) { M< - 0.15138) 5667 (1444 0.71 (18.0) ; > 0.160 (4.1) >] <- bee eet 5.625 (142.8 >| 155 TAT 1.50 sa7 8 TIATOBOS 0.073)] e] (39.4) (1821) (38.1) 7 . on a 23.750 male pil Sf Note: - 2 Negative () ES \ 3.00 Rotation: ed fr 3 - Positive (+) 2 q W viewed from i NS via ands lead end with red Recepiags Des D | lead positive.

10-32 UNF-28 x 0.40 (10.2) min deep

2 places

Oppdsité on a'2.625 (66.7) dia B.C.

p

4-40 UNC-2B x 0.30 (7.6) min deep 2 places opposite on a 1.812 (46.0) dia B.C.

x C-2B x 0.30 (7.6) min deep g es opposite on a 2.125 (54.0) dia B.C.

End cover mounting screws wistand offs -

2.x 8-32 UNC 2B x 0.30 (7.62) DP ly spaced on a @2.500°(63.5) B.C,

* 0.190 0-000 , 2.x 4-40 UNC 2B x 0.30 (7.62) DP equally - yet spaced on a 01.812 (46.02) B.C. as shown (4.82? Sorel

0.515 +/- 0.003 1.13 (28.7) < jon

+0.0076) (15.86 ~ 9.9000)

Shaft Detail

Page 58 read from a scan by OCR; it may hold reading errors

ESC

Immediately Stop Motor

EDIT

ENTR

DEL

Fi-0

Fi-5

F1-6

F1-7

F1-Edit F2-Edit F1-F2 Edit F1-F2-ENTR F1-F2-DEL F1-F2-1 F1-F2-3 F1-F2-8 F1-F2-9 - ESC &, - > ESC & + - Select Program to Edit

Enter Data or Initiate Command Select Program to Delete Display Available Memory

Test Outputs

Select Program to Run

Copy Program

Enter System Parameters

Enter Learn Mode Enter PID Parameters

. Display Software Revision Original Configuration: Erase memory Reset Current Position to Zero Send String Over RS232

Restore Default Values

System Reset

Jog Motor in Extend (+) direction Jog Motor in Retract (-) direction

Fi Function Range of Values 1 DA Distance Absolute _(/- 000.000 - 999.999 in or oma 2 DI Distance Increment (+/- 000.000 - 999.999 in or a) 3 DC Distance toChange (+/- 000.000 - 999.999 in or cm) 4 VE Velocity (1-100% of max speed) 5 OT Outputs Set (0=0ff, 1=on, 2=no change) 6 RN Run Program # (1-99) 7 TD Time Delay (.01-99999.99 sec.) 8 WT Wait On Inputs’ (0=grounded, 1=open,2=ignore) 9 GO Go.- Make Move 0 GH Go Home (1-100% of max speed) F2 Function Range of Values 1 AC Acceleration (.05 to 15 sec.) 2 DE Deceleration (.05 to 15 sec.) 3 IF IF-THEN (0=grounded, 1=open,2=ignore) 4 LP Loop (0 to 99999) 5 EL End of Loop 6 ST Stop On Input # (1-4) 7 CT Current Hold Time, (.01-99999.99 sec) 8 CL Current Hold Limit (0-1 00%) 9 EN End of Program 0 UV User Variable

Command _ Description Default Value -@ AC Acceleration .3 second ramp time

DE Deceleration .3 second ramp time

VE Velocity 25% speed

. Range

User Description of Values Default

MN Model Number XXXXXXXX 102

CCE Cur Overload Extend (0-100%) 65% Peak Cur.

CR Cur Overload Retract (0-100%) 65% Peak Cur.

CS Coordinate System (Oor1) Oo Ext=Positive

DP Display Mode (lor2) 1 normal

EC Echo RS232 (Oori) 1 echo on

HA Home Algorithm(mn) (Qor1) 01 RTR edge/N.O.

HO Home Offset (0-9.999) 0.0 disabled

JA Jog Acceleration (01-15) 4 sec

JV Jog Velocity (0-100%) 10% max speed

MU. Metric Units (Oor1) oO English

PU Power-up mode (0-99) 00 disabled

SD Stop on Input Decel Rate (.01-15) 1 second

Si System Inputs (mnxy) (0-8) 8800 User Prog/ disabled

SO System Outputs (mn) (0-6) 00 disabled

XP_ External Prog. Select (Qor1) 00 disabied

UN Unit Number (RS232) (1-99) 01 device 1

Range

Parameter Description of Values Default

PP Position - Proportional Gain (0-20) 10

PI Position - integral Gain (0-20) 10

PD Position - Derivative Gain (0-20) 10

VP Velocity - Proportional Gain (0-20) 10

Vi Velocity - Integral Gain (0-20) 10

VD Velocity - Derivative Gain (0-20) 10

LILN)

56

HS9S1/H4951 Linear Serve Controls

Page 59 read from a scan by OCR; it may hold reading errors

industrial Devices Corporation warrants all electrical cylinders and electronic conirollers to be free of defects in workmanship for a period of one year from the date of shipment to the end user.

Products that have expended their useful life in less than one year or have been improperly used or damaged, in the opinion of the company, are not subject to the terms of this warranty.

Industrial Devices Corporation maintains a repair facility at its factory in Novato, California for all units which Industrial Devices Corporation manufactures, including a complete inventory of parts to ensure quick service turn around.

Prior approval by Industrial Devices is required before returning a product for any reason. All return packages must be accompanied by an RMA (Return Material Authorization) number. To obtain an RMA#, contact your local IDC distributor or Industrial Devices.

Products returned prepaid to the factory will be repaired or replaced at the company's option at no charge, and returned prepaid to the user.

1. Get the Model and Serial number of the defective unit. 2. Prepare a purchase order for the repair cost if the unit is out of warranty. 3. Contact your IDC Distributor or Industrial Devices Corporation (at 1-800-747-0064) for a Return Material Authorization RMA#., Provide information describing the nature of the failure.

4. Ship the unit prepaid to:

Industrial Devices Corporation 64 Digital Drive

Novato, CA 94949

Attn: RMA # naw 2 or

»

Page 60 read from a scan by OCR; it may hold reading errors

For More Information

If you require further information on the H3951, To get quick response to specific information S H4951 or another Industrial Devices product, when calling Industrial Devices, ask for the please call your local IDC Distributor or area of expertise that relates to your question: Industrial Devices. : 1. Local IDC Distributor Technical Support? | ~ Company: Ask for Applications Engineering Contact: Phone #: Product Information, Repairs or Returns?

Ask for Inside Sales 2. Industrial Devices Corporation

1-800-747-0064 Were Nona f Industriay ,. -2¢8er Facil; 3925 G Devices Co ty! . f] y I 800-74hres Drive, Petaiyn ee 7789-0175, 07783-1069 4954 €ctive Feb, 1,19

Today, more than 10,000 individual Industrial Devices systems are in use, in an extensive variety of industrial, scientific and commercial applications. For information on other Industrial Devices’ electric linear Positioning systems, contact your local distributor or call us.

UL.) Industrial Devices Corporation mia ’ 64 Digital Drive - Novato, CA 94949 - 415/883-3535 - FAX 41 5/883-2094