The text of a manual · part 6 of 8
SCANTEAM 3700 CCD Technical Manual, pages 51 to 60
Pages 51 to 60 of 76
The original document is the PDF (454 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST3700
Page 51
Microprocessor The microprocessor controls the generation of timing signals required for the operation of the SCANTEAM 3700 device. Additionally it monitors the digital output of the device, configures the operating parameters sent through serial commands (as required), and decodes the scanned bar code data. Timing Sequence Figure A.2 illustrates the timing sequence for the SCANTEAM 3700.
Bar Code Symbol Being Scanned
Timing Shift Out Analog Data
Illumination
Analog Signal from CCD Array White
Black
Digital Data Out White
Black
Decoded Data (Decoded Output Only)
Figure A.2 SCANTEAM 3700 Timing Sequence CCD Operation and Bar Code Scanning
A–3
Page 52
A.3
Bar Code Basics and Scanning Tips A Closer Look At Bar Code Symbols The illustration at the right shows a typical bar code symbol. If you look at it closely, you’ll see it is composed of a series of dark lines (bars) and white areas (spaces) of various widths. By arranging these bars and spaces in a certain order, it is possible to represent, or “encode” letters, words and numbers.
0
42000
06200
You may also print the numbers represented by the bar code symbol on the label. These human readable characters allow you to know exactly what information the scanner is sending to the register or terminal. The human readable characters under the bar code symbol also allow you to key in information in case the bar code symbol is not readable. The blank area located just before and just after the bar space pattern is called the “quiet zone.” It is placed on the symbol so the scanner knows exactly where the bar code begins and ends. It is important to remember where the quiet zone is located so you can scan accurately. Bar Code Scanning The purpose of the bar code scanner is to “read” the image formed by the bars and spaces. A signal sends the information printed on the bar code symbol to the terminal. Several types of scanners are in use today. The most common types include the wand scanner, the laser scanner, and the CCD scanner. All scanners use optical systems which are protected by “windows” at the scanning end to read the bar code symbol. On wand scanners, the window is located in the tip. Laser and CCD scanners have a larger and more noticeable viewing “window.” It is important to keep these optics clean, because just like the lenses on reading glasses, if they become dirty, scratched or smudged, they won’t work properly. If your scanner is attached to a decoder (or it is also a decoder), the decoder may have a beeper that will let you know when a scan has been performed properly and that the bar code has been read accurately. After you’ve scanned a symbol, listen for a single beep, (called a “good read” beep). This lets you know that the bar code information has been received by the terminal. If you don’t hear the single beep or if you hear several beeps, it means the symbol is unacceptable to the decoder, and the terminal has not received the bar code information. If that happens, try scanning the symbol again. Before using any scanner, make sure the symbol is of good quality and that the optic area of your scanner is clean. Any dirt or specks in the bar code symbol or on the scanner optics may prevent it from reading accurately. Even a symbol that is smudged during printing, or gets wrinkled when it is applied to an object can cause a reading problem. If you can’t get a good read beep or you begin to receive error beeps, be sure to check the scanner optics and the symbol. The decoder may need to enable the beeper, either with a hardware configuration or with a software command.
A–4
CCD Operation and Bar Code Scanning
Page 53
B
TECHNICAL SPECIFICATIONS
B.1
Scanner Performance The SCANTEAM 3700 performance has been measured in terms of the first bar elongation/contraction and inner bar (space) elongation/contraction when scanning Welch Allyn test targets. If you need more information on these measurements, contact your Welch Allyn representative.
B.2
Optical Specifications Scanning Direction:
Single Line (Unidirectional)
Scan Rate:
100 scans per second See chart below.
Scan Speeds Scans/Second 100
Approximate Lateral Scan Speed Inch/Sec mm/Sec
375
9500
Lateral Motion Sensitivity:
5 inches per second (254mm/sec)
Scan Width:
2.4 inches [61mm] at contact 3.5 inches [89mm] maximum
Technical Specifications
B–1
Page 54
Focal Distance (selected at time of order) from scanner window: Focal Distance
Maximum Scan Width
0.6 inches [15mm] with a 3 inch [76mm] maximum scan width 1.95 inches [50mm] with a 3.5 inch [89mm] maximum scan width 3.2 inches [81.3mm] with a 3.5 inch [89mm] maximum scan width
MRD (minimum reflective difference): 37.5%
B–2
Tilt Angle:
Controlled by bar code length and height (See Figure 3.4)
Skew Angle:
+30 to –30 degrees (See Figure 3.4) Specular reflection zone 0 to –10 degrees (Operation in this zone must be avoided.)
Pitch Angle:
+7 to – 7 degrees on 7.5 mil (See Figure 3.4)
Light Source (Illumination):
Visible Red LED (Wavelength = 645 nm ±30)
CCD Type
Standard Resolution / Standard Performance Standard Resolution /Enhanced Performance High Resolution / Enhanced Performance
Technical Specifications
Page 55
B.3
Electrical Specifications Operating Voltage:
+5V+5% ✺
Operating Current:
170 to 250 mA, ✺ depending on scan rate for Standard Resolution / Enhanced Performance CCD type
✺ Power for the SCANTEAM 3700 is provided by the host system. Communications Port Connector Pin Assignments: See chart below. 1 10–Pin Modular Connector Communications Port
10
Pin
Signal
Function
1 2 3
Shield Trigger/Enable ✤
7
Ground RX Data TX Data VCC
Cord Shield Trigger Signal to Decoder Scanner Enable (Input) System Ground Receive Data (Input) Transmit Data (Output) +5VDC Power (Input)
8
RTS
Ready to Send (Output)
9 10
CTS
Clear to Send (Input)
4 5 6
✤ State depends on use Hardwire Option: See chart below. Four Pads for Hardwire to 3700 Motherboard
Pin
Signal
Function
1 2 3 4
BTS DIG IN DEFAULT IND
Bootstrap Second Scanner Input Reset Good Read
Technical Specifications
B–3
Page 56
Indicators:
Beeper. See descriptions below.
Beeper The good read/no read beeper indicator is configurable and can be disabled, if desired.
B.4
Environmental Specifications Operating Temperature:
32° F to 122° F (0° C to +50° C)
Storage Temperature:
–40° F to 158° F (–40° C to +70° C)
Relative Operating and Storage Humidity:
0 to 95% (non–condensing)
Barometric Pressure:
101,000 to 69,000 Pascals (Sea level to 3000 meters)
ESD:
15 KV ✺
✺
A drain path for ESD should be provided when installing a 3700 in the host system.
Shock (Drop Test):
Sustains three (3) drops from 4 feet (1.2 meters) to a non–yielding surface
Mean Time Between Failure (Ground Benign):
B.5
Mechanical Specifications 3700:
Width: Length: Height:
Interface Cables:
1) Welch Allyn p/n 42204595–01 Input/Output cable with 25 pin connector.
Note:
3.5 Inches (89mm) 2.9 Inches (75mm) 1.05 Inches (26m)
A null modem is required for connection to a DTE type port.
Mounting Holes:
B–4
45,000 hrs. minimum (will vary among models)
Technical Specifications
Four #6–32 UNC–2B (M3.5) (Alternate dimensions available.)
Page 57
B.6
Bar Code Symbol Specifications All bar code symbols should satisfy the appropriate AIM Uniform Symbology Specification.
Background Substrate The bar code symbol should be printed on material which is reflective and has a matte (not glossy) finish. A background diffuse reflectance of at least 70% to 80% is desirable for optimum contrast. Ink Color and Type The type of ink should be compatible with 660nm LEDs used in the scanner. The bar code symbols inked bars should not exceed 10% reflectance at 660nm which is being used for reading, whether printed with black ink or colored ink. Voids and Specks The code should be printed clearly, free of voids, specks, blemishes and lines which could “fool” the scanner. Specks or blemishes in the white spaces, or false or missing bar sections could be interpreted by the reading equipment as part of the code. Generally, the width of such flaws is more serious than the height. Code symbols should be rejected if these defects are present. Definition The bars in the bar code symbol should be well defined. Their edges should not be rough or fuzzy, so that the bars and spaces have the proper widths intended for the bar code symbology used. Since a scanner’s aperture and resolution are chosen to comply with these widths, definition should be sharp and consistent. Tolerance The ratio of the widths of bars and spaces in a bar code symbol must conform to the appropriate AIM bar code specifications and can cause problems if not correct throughout the bar code. Problems can occur when bar edges are smeared or rough, or when they exhibit voids.
Technical Specifications
B–5
Page 58
B.7
SCANTEAM 3700 Interface Cable Cable part number: 42205204–01 or 42205204–02 (external power required) Caution: Do not substitute any other Welch Allyn serial interface cable.
To SCANTEAM 3700 Interface Port
To Host System
P2
P1
P3 Optional connector for external power supply
P1
P2
10 Pin RJ41 Modular Pin 1
9 Pin D Female Pin5 Pin 1
Pin 10
Pin 9
Connector Pinouts 1 TRIG 2 TX 3 RX 4 Unused 5 GND 6 Unused 7 CTS 8 RTS 9 VCC or Unused* Shell Shield/Drain
Connector Pinouts 1 2 Shield/Drain 3 TRIG – Trigger/Enable (input) 4 GND– Ground 5 RX – Receive Data (input) 6 TX – Transmit Data (output) 7 VCC (+5VDC – input) 8 RTS – Ready to Send (output) 9 CTS – Clear to Send (input) 10
Optional: P3
*Pin 9 is unused if an external power supply is used (P3).
4 Pin Mini–Din Female Pin 4
Pin 3
Pin 2
Pin 1
Connector Pinouts 1 VCC 2 GND 3 Unused 4 Unused Shell Shield/Drain B–6
Technical Specifications
Pin 6
Page 59
SERIAL COMMANDS SUMMARY
C.1
C
Configuration Commands The following is a summary of configuration commands sent by the host system. More details are provided in Section 4.4, Configuration Commands.
Note:
These commands may contain port–specific data not relevant to the SCANTEAM 3700 machine mount CCD. This extra data will be accepted, but ignored. These items are identified in the command descriptions by a pound sign (#).
Command
Format
Set Communications Port Command Set Preamble Command Set Postamble Command Set Communications Protocol Command Set Trigger Mode Command
<Ka baud, parity, stop bits, data bits> <Kd enable, data> <Ke enable, data> <Kf mode> <Kg mode_global, mode_port_1, mode_port_2, #> <Kh mode_global, time_global, mode_port_1, time_port_1, mode_port_2, time_port_2, #, #> <Kk enable, data> <Km data_global, data_port_1, data_port_2, #> <Kp enable, require checksum, send checksum, minimum length, maximum length> <Kq enable, send start/stop, minimum length, maximum length> <Kr enable, require checksum, send checksum, minimum length, maximum length> <Ks enable UPC, enable EAN> <Kt enable, minimum length, maximum length> <Ku mode_global, mode_port_1, mode_port_2, #>
Set Read Timeout Command
Set No Read Message Command Set Votes Command Set Code 39 Command
Set Codabar Command Set I 2 of 5 Command
Set UPC A/E, EAN 8/13 Set Code 128 Command Set Beeper Mode
Serial Commands Summary
C–1
Page 60
C.2
Operational Commands The following is a summary of operational commands sent by the host system. More details are provided in Section 4.3, Operational Commands.
C.3
Command
Format
Reset Command Disable Scanning Command Enable Scanning Command Serial Trigger Command Save Configuration Command
<A> DC4 DC2 <1> <Z>
Configuration Status Query Commands The following is a summary of configuration status query commands sent by the host system. More details are provided in Section 4.5, Configuration Status Query Commands. Command
Format
Configuration Query ✺ <?> ✺ Causes the entire series of individual status messages to be output. Individual Configuration Query <K✤?> ✤ Stands for the letter of the individual configuration command. Causes a single configuration status message to be output. To determine the current configuration status for an individual configuration command section use the appropriate query string indicated below:
C–2
Command
Format
Communications Port Status Preamble Status Postamble Status Communications Protocol Status Trigger/Enable Mode Status Read Timeout Status No Read Message Status Votes Status Code 39 Status Codabar Status I 2 of 5 Status UPC, EAN Status Code 128 Status Beeper Status Scan Rate
<Ka?> <Kd?> <Ke?> <Kf?> <Kg?> <Kh?> <Kk?> <Km?> <Kp?> <Kq?> <Kr?> <Ks?> <Kt?> <Ku?> <Kv?>
Serial Commands Summary