The text of a manual · part 5 of 8
SCANTEAM 3700 CCD Technical Manual, pages 41 to 50
Pages 41 to 50 of 76
The original document is the PDF (454 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST3700
Page 41
4.5
Configuration Status Query Commands The configuration status query commands are used to obtain a status listing of the configuration command selections. You may request a listing of the entire series of individual configuration status messages or you may request the status of a single configuration status message be output to your host system or terminal. Descriptions and ASCII characters for the configuration commands follow. Note:
The commands in this section are shown in ASCII format only. Refer to Appendix D for an ASCII conversion chart.
The following command causes the entire series of individual configuration status messages to be output to the host system: <?> – configuration query. Fifteen configuration status query commands recognized by the SCANTEAM 3700 are: <Ka?> – communications port status <Kd?> – preamble status <Ke?> – postamble status <Kf?> – communications protocol status <Kg?> – trigger/enable mode status <Kh?> – read timeout status <Kk?> – no read message status <Km?> – votes status <Kp?> – Code 39 status <Kq?> – Codabar status <Kr?> – Interleaved 2 of 5 status <Ks?> – UPC, EAN status <Kt?> – Code 128 status <Ku?> – beeper status <Kv?> – scan rate status Each configuration query will cause the current status of the selected option to be output in a format identical to the configuration command string itself, except that global fields are excluded. For example, if the trigger mode_global is set to 5 <Kg?> will result in <Kg , 5, 5> being output by the 3700. Except for the Communication Port Command, configuration commands take effect immediately upon receipt by the 3700. Therefore most configuration commands can be verified as having been received by the 3700 by immediately following the command with a status query. For the Communications Port Command to become effective, the command must be followed by a <Z><A> (save configuration and reset the 3700 commands) since the port is only initialized upon a reset. Since the 3700 reports the current configuration of the port itself, the status query <Ka?> will not indicate if a Communications Port Configuration Command has been received correctly until the <Z><A> has been received. All status output strings will include the current preamble and postamble. Thus if the preamble is set to DC1 and the postamble to DC3 then a postamble status query <Ke?> will result in the output string DC1<Ke1,DC3>DC3. The receiving system must be able to handle the embedded DC3 and not treat it as the termination of the string. Configuring the SCANTEAM 3700
4–15
Page 42
4.6
Default Operating Parameters The SCANTEAM 3700 is configured at the Hand Held Products factory with standard (default) operating parameters. The default configuration can be used as is or changed (reconfigured) by downloading new parameters over an RS–232 communications line from a host instrument. The default configuration settings are listed below. Default Configuration Settings • ACK / NAK Disabled • Baud Rate 9600 • Beeper Mode Disable beeper • Data Bits 7 • No Read Message “NR” • Parity Even • Postamble CR LF • Preamble Port ID Code ID • Read Timeout Timeout ends a read attempt, 1.5 seconds • RTS/CTS Disabled • Stop Bit 1 • Trigger Mode Serial Trigger or External Trigger, Read Once • Votes Voting set to 3 for port 1 and set to 1 for port 2 • XON/XOFF Disabled Default Configuration: Symbology Settings • Codabar Enabled Send Start/Stop Yes Minimum Length 6 Maximum Length 60 • Code 39 Enabled Require Checksum No Send Checksum No Minimum Length 1 Maximum Length 48 • Code 128 Enabled Minimum Length 1 Maximum Length 80 • I 2 of 5 Disabled Require Checksum No Send Checksum No Minimum Length 6 Maximum Length 80 • UPC A/E, EAN 8/13 Enabled
4–16
Configuring the SCANTEAM 3700
Page 43
SERVICE/TECHNICAL ASSISTANCE
5.1
5
Maintenance The Hand Held Products SCANTEAM 3700 Machine Mount CCD Bar Code Scanner and Decoder is designed to provide reliable and efficient operation, requiring no routine maintenance. The 3700 has no moving physical parts. Convection air flow serves to cool the unit. Maintenance, therefore is related to troubleshooting and replacement of the 3700 Machine Mount CCD. Troubleshooting procedures are described in the following section. Section 5.4 provides procedures for removing and replacing a SCANTEAM 3700 Machine Mount CCD.
5.2
Troubleshooting Guide This section describes procedures for identifying problems that prevent the SCANTEAM 3700 from operating normally. Field repair procedures include the following: • Power supply troubleshooting • 3700 Machine Mount CCD troubleshooting 5.2.1
Warning:
Troubleshooting Hints If there is no power to the 3700 Machine Mount CCD, check the following: •
Host power supply output to the 3700. Check that the output voltage from the host is +5 VDC. If the voltage isn’t present or is out of range, there may be a problem with power distribution from the host system. Appendix B provides the specific voltage range.
•
If there is no output voltage, check to be sure the host instrument power switch is set to “ON”; if this switch is on and there is no output voltage, there may be a problem with the host power supply.
•
Check all cables for secure connections and continuity (with an ohm/volt/meter).
Only a qualified person should attempt to replace a power supply.
Service/Technical Assistance
5–1
Page 44
5.2.2
Diagnostic Procedure The SCANTEAM 3700 Machine Mount CCD may be reset to the last saved configuration parameters by issuing a Reset Command. (A list of these parameters may be found on in section 4.6 and C.4.) •
5.2.3
To perform a Reset Command, send an <A> serial command to the 3700. This action causes all data in memory to be erased and the current user configuration parameters to be loaded from non–volatile memory. In the absence of a user configuration, the default configuration is loaded into memory. This action allows the user to clear memory of any corrupt data from scanned data.
Troubleshooting Checklist
Problem
Possible Cause
Solution
3700 does not scan.
1) Loose I/O communications cable. 2) Trigger mode not configured correctly.
1) Connect cable. 2) Configure the 3700 for the proper trigger mode and read timeout value. 3) Provide trigger consistent with the trigger mode configuration.
3) Not triggered. 3700 is not reading bar code.
1) Bar code symbol type is disabled. 2) Symbol length is out of range. 3) Symbol does not contain a valid checksum character. 4) Bar code is bad, damaged or out of spec. 5) Window is scratched or dirty.
1) Enable the symbology. 2) Configure the 3700 for correct length. 3) Configure the 3700 to not require checksum or use a label with a valid checksum. 4) Replace bar code. 5) Clean window.
Beeper does not come on. 1) 3700 is not decoding. 2) Good read is disabled.
1) See “3700 is not reading bar code.” 2) Configure the 3700 for desired good read operation.
Data is not transmitted.
1) Connect cable. 2a) Have the receiving equipment generate CTS. 2b) Disconnect CTS signal allowing the 3700 to force CTS to the active state. 3a) Send an XON to the 3700. 3b) Configure the 3700 to disable XON.
1) Loose I/O communications cable. 2) 3700 is waiting for clear to send (CTS). 3) 3700 is waiting for XON.
Data message is missing or garbled.
Baud rate, parity, stop bits or data bits is wrong.
Configure the 3700 for the proper communications parameters.
Table 5.1 SCANTEAM 3700 Troubleshooting Checklist
5–2
Service/Technical Assistance
Page 45
5.3
Obtaining Factory Service Hand Held Products provides service for all its products through a service center located at its manufacturing facilities in Skaneateles, New York. To obtain warranty or non–warranty service, return the unit to Hand Held Products (postage paid) with a copy of the dated purchase record attached. In the United States, please contact the Hand Held Products’ Product Service Department at the address/telephone number listed below to obtain a Return Material Authorization number (RMA #). Main Office Welch Allyn Data Collection, Inc. (d/b/a Hand Held Products) 4619 Jordan Road P.O. Box 187 Skaneateles Falls, New York 13153–0187 Product Service Department Telephone: (315) 685–4278 or 685–4360 Fax: (315) 685–4156 For service in Europe, please contact your Hand Held Products’ representative (at the address that follows) or your local distributor. European Office Hand Held Products, Ltd. Hondsruglaan 87 D 5628 DB Eindhoven The Netherlands Telephone: Int+ 31 40 242 4486 Fax: Int+ 31 40 242 5672 United Kingdom Office Hand Held Products (UK) Ltd. Dallam Court Dallam Lane Warrington Cheshire WA2 7LT United Kingdom Telephone: or Fax: or
Int+44 (0) 1 925 240055 Int+353 1 216 0070 Int+44 (0) 1 925 631280 Int+353 1 295 6353
For service in Asia, please contact your Hand Held Products’ representative (at the address that follows) or your local distributor. Asia/Pacific Office Hand Held Products 10/F Tung Sun Commercial Centre 194–200 Lockhart Road Wanchai, Hong Kong Telephone: Int+852–2511–3050 or 2511–3132 Fax: Int+852–251–1355 For service in Japan, please contact your Hand Held Products’ representative (at the address that follows) or your local distributor. Service/Technical Assistance
5–3
Page 46
Japan Office Hand Held Products Bon Marusan 8F 3–5–1 Kanda–Jinbocho Chiyoda–ku Tokyo 101, Japan Telephone: Int+81–3–5212–7392 Fax: Int+81–3–3261–7372 For service in Latin America, please contact your Hand Held Products’ representative (at the address that follows) or your local distributor. Latin America Office Hand Held Products 5150 North Tamiami Trail Suite 302 Naples, FL 34103–2821 Telephone: (941) 263–7600 Fax: (941) 263–9689
5.4
Help Desk If you need assistance installing or troubleshooting your scanner, please call your Distributor or the nearest Hand Held Products technical support office: North America: Telephone: (315) 685–2476 (8 a.m. to 6 p.m. EST) Fax number: (315) 685–4960 E–mail: support@handheld.com Europe: Telephone– European Ofc: Int+31 40 242 4486 U.K. Ofc: Int+44 1925 240055 E–mail: support@handheld.com Asia: Telephone: Int+852–2511–3050 or 2511–3132 E–mail: support@handheld.com
5–4
5.3.1
Service Under Warranty All Welch Allyn bar code products carry a one (1) year warranty (from date of shipment). The specific Limited Warranty coverage for the SCANTEAM 3700 Machine Mount CCD is described near the end of this manual. Warranty service may be obtained by contacting the Welch Allyn Customer Service Group.
5.3.2
Out Of Warranty Service Factory service is also available for out of warranty products on a time and materials or fixed price basis. The scanner/decoder should be returned (postage paid) for repair only after obtaining a Return Material Authorization (RMA) from a Customer Service Representative. When out of warranty product service is required, you will be advised of a “not to exceed” price for repair when the Return Material Authorization is requested.
Service/Technical Assistance
Page 47
The following information is required to process an RMA for the product and should be available for the Service Representative. It is located on the manufacturers label attached to the box the SCANTEAM 3700 was shipped in. Model Number Serial Number Date of Manufacture Note:
The Welch Allyn Customer Service Group cannot accept materials that are returned without an RMA number.
When out of warranty service is required the Customer Service Representative will request a Purchase Order Number in the amount of the “not to exceed” price for repair. However, customers will be billed only for the actual service costs.
5.4
SCANTEAM 3700 Removal/Replacement The application intention of the 3700 makes it a component of the host controlled instrument. Power to the host system must be turned off before removing the 3700 Machine Mount CCD. Removing the 3700 involves reversing the steps that you followed during installation (Chapter 3).
Caution:
Note:
Some circuits in the 3700 Machine Mount CCD are sensitive to electrostatic discharge. Be sure you are properly grounded before removing the 3700 from the host system. Set the host instrument power switch to the “OFF” position.
Step 1: Disconnect the data communications / power cable between the 3700 Machine Mount CCD and the host system (see Chapter 2, Figure 2.2 for the exact location of the port on the 3700). Step 2: Using a screwdriver, remove the mounting screws, if applicable, from the 3700 Machine Mount CCD. Step 3: Remove the 3700 Machine Mount CCD and place it immediately into an antistatic container or an antistatic bag. This completes the 3700 Machine Mount CCD removal procedure. For replacement vinstructions, please follow the set–up and installation procedures in Chapter 3.
Service/Technical Assistance
5–5
Page 48
5–6
Service/Technical Assistance
Page 49
CCD OPERATION AND BAR CODE SCANNING
A.1
A
Objectives This appendix describes: • Reading and decoding a bar code symbol. • Overview of how the SCANTEAM 3700 works, including a scanner diagram with the main decoding elements listed. • In–depth discussion of the operation of the scanner, including a block diagram and discussion of the internal parts of the scanner, and a timing sequence diagram. • Bar code basics and scanning tips.
A.2
Scanning and Decoding a Bar Code Symbol The body of the SCANTEAM 3700 houses all the scanning elements, and decoding/interface elements. Refer to Figure A.1.
LED Reflector LED Pulse Generator Bar Code Symbol
CCD Sensor
Aperture
Decoding/Interface
Power Supply, Digitizing, Microprocessor, Signal Processing, and Control Circuitry
Lens
Cable Modular Connector
Bar Code Label Image Pixel Array
Figure A.1 Main Elements of the 3700 CCD Bar Code System The SCANTEAM 3700 performs the following steps when scanning and decoding a bar code symbol: 1.
The scanner turns the LEDs (Light Emitting Diodes) inside the scanner ON, and the light from the LEDs illuminate the bar code symbol. CCD Operation and Bar Code Scanning
A–1
Page 50
2.
The black bars on the symbol absorb the LED light, while the white spaces scatter the LED light.
3.
A portion of the scattered light re–enters the scanner’s optical system and is detected by the pixels of the CCD (Charged Coupled Device).
4.
The CCD converts the returned light into a sequence of electrical pulses with amplitude proportional to the energy level of the scattered light.
5.
The digitizer converts the analog light signal to a bit serial representation of the bar code symbol. The width of the binary signal pulse being proportional to the width of the bars and spaces of the bar code symbol.
6.
The Decoding Circuitry decodes the digitized pulses into characters of data representative of the bar code symbol.
7.
After a successful decode is complete, a beeper is sounded (if enabled to indicate a Good Read). The decoded information is transmitted to the host.
8.
Depending upon the trigger chosen, the scanner either continuously initiates another scan cycle or waits for the next trigger to scan.
LED Reflector The bar code symbol is illuminated with a bank of LEDs with a proprietary reflector. The LEDs are pulsed, strobing illumination, to stop relative motion of the scanner and the label. CCD Sensor The optical energy scattered from the bar code symbol is focused with a custom lens onto the pixel array of the CCD sensor. The switching transients from the CCD are removed with analog filters. This filtered signal is then an analog representation of scattered light incident on the CCD. Peak Detectors and Comparator The positive and negative peak detectors retain the signal level associated with the minimum black and maximum white reflectances respectively. The comparator threshold is then set at a point between the black and white peak reflectance levels. The threshold level and the analog representation of the scattered light are then compared with a comparator, generating the bit serial digital representation of the bar code symbol.
A–2
CCD Operation and Bar Code Scanning