The text of a manual · part 7 of 8
SCANTEAM 3700 CCD Technical Manual, pages 61 to 70
Pages 61 to 70 of 76
The original document is the PDF (454 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST3700
Page 61
C.4
Default Configuration Settings The following is a summary of default configuration settings. Configuration CommandDefault Settings ACK / NAK Baud Rate Beeper Mode Data Bits: No Read Message Parity Postamble Preamble Read Timeout RTS/CTS Stop Bit: Trigger Mode Votes XON/XOFF
Disabled 9600 Disable beeper 7 “NR” Even CR LF Port ID Code ID Timeout ends a read attempt, 1.5 seconds Disabled 1 Serial Trigger or External Trigger, Read Once 3 votes for port 1 and 1 vote for port 2 Disabled
Symbology Configuration
Default Settings
Codabar
Enabled Yes 6 60 Enabled No No 1 48 Enabled 1 80 Enabled Disabled No No 6 80 Enabled
Send Start/Stop Minimum Length Maximum Length Code 39 Require Checksum Send Checksum Minimum Length Maximum Length Code 128 Minimum Length Maximum Length EAN 8/13 I 2 of 5 Require Checksum Send Checksum Minimum Length Maximum Length UPC A/E
Serial Commands Summary
C–3
Page 62
C–4
Serial Commands Summary
Page 63
D
ASCII CONVERSION TABLE
BIT NUMBERS 0
0
0 0
0
0 1
1
0 0
1
1 1
0
1 0
0
1 1
1
1 0
1
1
COLUMN b
7 b
6 b
5 b
4 b
3 b
2 b
1
0
1
2
3
4
5
6
7
DLE
ROW
0
0
0
0
0
NUL
SP
0
@
P
‘ p
0
0
0
1
1
SOH DC1
!
1
A
Q a q
0
0
1
0
2
STX
DC2
”
2
B
R b r
0
0
1
1
3
ETX
DC3
#
3
C
S c s
0
1
0
0
4
EOT DC4
$
4
D
T d t
0
1
0
1
5
ENQ NAK
%
5
E
U e u
0
1
1
0
6
ACK SYN
&
6
F
V f v
0
1
1
1
7
BEL
ETB
’
7
G
W g w
1
0
0
0
8
BS
CAN
(
8
H
X h x
1
0
0
1
9
HT
EM
)
9
I
Y i y
1
0
1
0
10
LF
SUB
*
:
J
Z j z
1
0
1
1
11
VT
ESC
+
;
K
[ k
{
1
1
0
0
12
FF
FS
,
<
L
\ l
|
1
1
0
1
13
CR
GS
–
=
M
] m
}
1
1
1
0
14
SO
RS
.
>
N
^ n
~
1
1
1
1
15
SI
US
/
?
O
_ o
DEL
CONTROL FUNCTION DEFINITIONS
NUL
Null, or all zeros
DC1
Device control 1
SOH
Start of heading
DC2
Device control 2
STX
Start of text
DC3
Device control 3
ETX
End of text
DC4
Device control 4
EOT
End of tranmission
NAK
Negative acknowledge
ENQ
Enquiry
SYN
Synchronous idle
ACK
Acknowledge
ETB
End of transmission block
BEL
Bell, or alarm
CAN
Cancel
BS
Backspace
EM
End of medium
HT
Horizontal tabulation
SUB
Substitute
LF
Line Feed
ESC
Escape
VT
Vertical tabulation
FS
File separator
FF
Form feed
GS
Group separator
CR
Carriage Return
RS
Record separator
SO
Shift out
US
Unit separator
SI
Shift in
SP
Space
DLE
Data link escape
DEL
Delete
ASCII Conversion Table
D–1
Page 64
D–2
ASCII Conversion Table
Page 65
SCANTEAM 3700 GLOSSARY
AIM– is the Automatic Identification Manufacturers, Inc. AIM is an industry organization that supports the application of all varieties of automatic identification technology including bar codes. An important contribution has been AIM’s efforts to standardize bar code symbologies and the way they are identified in data communication. Algorithm– is a finite set of rules to solve a problem in a measurable number of steps. It is a predetermined numerical calculation which is permanently programmed into the data system’s memory to provide a desired result (bar code decoding, for example). Ambient Light Immunity– describes the ability of a scanner to maintain its specified scanning ability in the presence of external light sources. Usually, scanners are specified for incandescent, florescent, and sunlight. Analog– (used in contrast to Digital) describes a signal whose amplitude is directly proportional to the physical factors responsible for the signal. An example of this is an optical sensor’s output depicting the bars and spaces of a bar code as it “sees” it. ASCII– is an acronym for the American Standard Code for Information Interchange. It is a data communications protocol for data transmission between an originating and a destination interface. 128 coded characters are included, comprising 96 noncommunications data characters and 32 control characters. It should be noted that most bar code symbologies are unable to encode the full ASCII set. Asynchronous Serial Communication– is a form of data communication transmission which occurs without a regular or predictable time relationship. The transmission of data characters is one at a time. Autodiscriminates– refers to the ability of the SCANTEAM 3700 to recognize and decode multiple bar code symbologies. Bar code– is an array of parallel bars and spaces arranged in a predetermined pattern to represent data elements called characters. Baud Rate– is a means of expressing data transmission speed, where “baud” equals the number of signal events per second (roughly equivalent to bits per second). Beam Velocity– is the speed of a laser’s scanning beam on the target. Bidirectional– refers to the ability of a scanner to scan a bar code in either a left–to–right or right–to–left direction. Bit– is a contraction of “binary digit,” the smallest unit of information used in data processing.
Glossary–1
Page 66
Buffer– refers to a storage facility in a data communications system which can compensate for a difference in time or rate of data transmission. Byte– is a group of 8 bits handled as a unit. Character (Bar code)– is group of bars and spaces which represents a single number, letter, mark or other graphic element. Check Character or Digit– is a special character which is part of the bar code and can be generated by an algorithm, and used to insure data integrity. When transmitted, the same algorithm can be used by the host on the data characters and this independent calculation can be compared to the transmitted check character. This procedure can also be accomplished wholly within the decoder. Often the check character is not transmitted because it is not a data character. Codabar Start and Stop Enabled– is a decoder option. When enabled, the capital letters representing the start and stop characters will be included in the data message. Code ID– is a letter that designates the symbology which has been decoded. The Code ID can be included in the data preamble or postamble to identify the scanned symbology to the host device. Welch Allyn has a standard set of lower case Code ID’s. These are given in Table 4.2. See also Port ID. Code 39 Check Character Included– is a decoder option. When enabled with Code 39 check character required, the check character will be confirmed and included in the data message. Code 39 Check Character Required– is a decoder option. When enabled, Code 39’s checksum will be calculated and confirmed for a valid read. (Host) Computer– is the data system’s controlling processor which interfaces with the decoder (either directly or through a multiplexer) and other system elements to receive their data outputs and command their functions. Decoder– (bar code) is a microprocessor based electronic device which translates the electrical signals from a bar code scanner into recognizable or computer compatible data. Decoding Enabled– is a decoder option that allows the decoding of an individual bar code symbology to be enabled or disabled. Density (Bar code)– refers to the number of characters in a linear inch of bar code. Depth of Field– refers to the range of distances over which a scanner can accurately digitize barcode. This distance is measured from the front of the scanner at the exit window and is dependent on code size, contrast, and quality. Depth of field is equal to the far distance minus the near distance (∆ distance).
Glossary–2
Page 67
Digital– (used in contrast to Analog) describes a coded squarewave signal (processed from an analog signal) which is utilized by decoding circuitry. Digital bar code is generally square wave pulses (0 to 5 volts) with widths which depict the bar and space widths in the code. DIP– is an acronym for “dual in–line pins,” a type of integrated circuit package. DIP components are used with through–hole or viahole circuit board technology. Exit Window– is the optical opening through which the laser beam, or other method of illumination, leaves the scanner. Far Distance– is the farthest distance that a scanner can accurately digitize a given bar code. Field Width– is the window width. Refers to the greatest width of bar code label that can be successfully interpreted. Firmware– is a term for software which is permanently designed into a data system device (such as a bar code decoding algorithm) to provide special programs and service routines. Focal Distance– is the distance of highest resolution in front of the scanner window. Host Computer– refers to the data system’s controlling processor which interfaces with the decoder and other system elements to receive their data outputs and command their functions. Interleaved 2 of 5 Check Digit Included– is a decoder option. When enabled with Interleaved 2 of 5 check digit required, the check digit will be confirmed and included in the data message. Interleaved 2 of 5 Check Digit Required– is a decoder option. When enabled, Interleaved 2 of 5’s checksum will be calculated and confirmed for a valid read. Laser Enable– is a scanner input signal that controls the flow of power to the scanner. Usually this signal will control all the scanning functions in the scanner. LED– is an acronym for “light emitting diode.” Marker Beam– refers to a visual indicator that an infrared laser beam is present. The marker beam is an aid to pointing a hand–held or set up a machine mount scanner. This beam is not necessary for the optical performance of the laser scanner. Message Length– refers to the number of characters in the data message decoded from a bar code label.
Glossary–3
Page 68
Minimum and Maximum Message Lengths– refers to how the various symbologies may be restricted in code length to minimize the chances of misreading a bar code. By setting the message length, the decoder will count the data characters plus any others (start/stop, check digit, etc.) and only accept those bar code reads that fall within the set message length parameters. The default values of the minimum and maximum message lengths are indicated in section 4.4 under the specific configuration commands for setting the bar code symbologies. Near Distance– is the nearest distance that a scanner can accurately digitize a given bar code. No Read, Non–read, Non–scan– is the absence of data at the scanner output after an attempted scan due to no code, defective code, scanner failure or operator error. Non–volatile– refers to the characteristic of a device which allows it to retain data in memory when power is lost or turned off. Optical Axis– is a line extending from the center of the exit window to the midpoint of the usable scan length. Parity– is a means of checking character bit patterns for validity by confirming if they contain an Even or Odd number of “1”s. PLCC– is an acronym for “plastic leaded chip carrier,” a type of integrated circuit package. PLCC components are used in surface mount circuit board technology. Port– refers to the electrical connector on a decoder, computer or other system component through which data is transmitted or received. Port ID– is a number that designates the scanner port from which a bar code signal has been decoded. The Port ID can be included in the data preamble or postamble to identify the scanner input port to the host device. The Port ID numbers are given in Table 4.1. See also Code ID. Protocol– refers to a set of procedures for establishing and controlling data transmissions. Quiet Area– is an area of clear space, containing no dark marks, which precedes the start character of a symbol and follows the stop character. Also known as Quiet Zone. RS–232–C– is a set of rules which govern the transfer of data between Data Terminal Equipment (DTE) and Data Communications Equipment (DCE), effected through 25 pin plug–in connectors. This standard applies to both synchronous and asynchronous transmissions at speeds up to 20K bps (bits/sec) in full or half–duplex modes. Scan Enable– is a scanner input signal that controls the flow of power to the scanner. Usually this signal will control all the scanning functions in the scanner.
Glossary–4
Page 69
Scan Rate– is the number of times a laser’s scanning beam passes through the exit window in one second. Scan Velocity– is the speed of a laser’s scanning beam on a target at a given distance from the front of the scanner or rotating polygon mirror. Usually expressed in inches/sec. Scan Width– is the length of the widest bar code label that can be successfully interpreted by the scanner. Scanner– is an opto–electronic device which produces electrical signals representing the light it detects as it “sees” a bar code. SMT– is an acronym for “surface mount technology.” Specular Reflection Zone – The zone where light from the scanner’s illumination source is reflected directly back into the scanner. Specular reflection interferes with the scanner’s operation. This zone should be avoided. Start/Stop Characters– are characters used at the beginning and end of a bar code label that indicate the start and stop (end) of the label. Trigger– is a signal input to the decoder that the scanning process should be initiated. The actual trigger mechanisms can be a push button switch, photoelectric control, internal object sense, proximity sensor, or multiple combinations of all of these. Usable Scan Length– refers to that portion of the scan path for which the scanner can accurately digitize bar code and maintain all its specifications. This length is specified on a flat surface which is perpendicular to the optical axis of the scanner. Volatile– refers to the characteristic of a device which loses data in memory when power is lost or turned off. Voltage Range– refers to the specified range of voltages over which a decoder or a scanner can maintain all of its electrical, optical (for scanners), and environmental specifications. Voting– is a feature of the SCANTEAM 3700 set by using the Set Votes Configuration Command, Km. If the Voting selection is set to more than 1, the SCANTEAM 3700 decodes and compares consecutive outputs from the scanner(s); successive reads of the same data are required for a valid read. Voting results is a slightly slower read rate, but will reduce the probability of reading errors when a laser scanner, especially, is being used. If the Voting selection is set to 1, only one laser scan resulting in a successful decode is required for a valid read.
Glossary–5
Page 70
Glossary–6