Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 26

Cordless Scanning System, System Manual: SCANTEAM 2070 Base, IMAGETEAM 3870/75 Linear Imager, SCANTEAM 5770 Laser: Introduction and Installation, pages 29 to 36

Pages 29 to 36 of 232, from Cordless Scanning System, System Manual: SCANTEAM 2070 Base, IMAGETEAM 3870/75 Linear Imager, SCANTEAM 5770 Laser

The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST2070, HHP ST3870 and HHP ST5770

Page 29

that the antenna is in a vertical (straight up and down) position whenever possible. An extra Base Association Bar Code is provided in case the base is mounted where the label might be difficult to scan (the Association process is described on page 1-10).

RS-232 Interface In an RS-232 configuration, connect your interface cable between the base unit and the host system (steps 1-3, shown in the illustration below). You also need to use an external power supply. Contact your distributor for more information on ordering power supplies or RS-232 cables.

RS-232 Interface Example Terminal (Host system)

2 Cordless Base

1 3

Power Supply

(Cable, keyboard, and terminal may vary.) 3. Turn on the power to the host system. Verify that the base is on; the green LED on top of the unit should be on. (The base does not have a beeper.)

1-9

Page 30

4. Using the cordless scanner, scan the Association Bar Code (the bar code label on the top of the base) to link that scanner to the base. Linear Imager or Laser Scanner Association Bar Code

Cordless Base

Two quick beeps followed by clicking, then a single beep indicates a “good” association. The scanner is in communication with the base. If the scanner clicks for 30 seconds and signals an error (triple beep), it has not associated with the base. Note: If the charge pack is removed from the scanner and replaced after association, the scanner automatically reassociates to the base, if the base has power. In this case, the scanner beeps when a charged charge pack is installed, then beeps a second time after full association, typically five to ten seconds later.

Note: A scanner always defaults to work group 0 after scanning a base I.D. bar code. 5. After your cordless scanner has been associated with its base unit, program the system to work with your terminal or computer by scanning the Terminal Setup Codes. Use the Supported Terminal list (page 2-6) to scan your terminal’s Terminal ID. With Plug and Play programming, you scan only one bar code to program the cordless system to work with a designated interface, including any required prefixes and suffixes. 6. To determine if your cordless system is set up correctly, scan one of the sample bar codes in the back of this manual.

1 - 10

Page 31

Connecting More Scanners to the System Up to nine cordless scanners may be associated with one base unit. Add more cordless scanners to a base unit by following the steps shown below: 1. Make sure the cordless scanner’s charge pack has been fully charged. 2. Scan the Association Bar Code (the bar code label on the top of the base) to link each scanner to the base. The base stores a unique I.D. for each scanner (up to nine) to identify the scanner during data communication. Two beeps followed by clicking, then a single beep from the scanner indicates a “good” association. The base rejects a tenth cordless scanner trying to link to its network, sending the scanner an error command. (A rejected scanner beeps three times, indicating an unsuccessful association.)

Note: When you associate more scanners with the base, you don’t have to program your cordless system to communicate with your terminal or computer if you’ve already completed step 5 on page 1-10.

1 - 11

Page 32

Beeper and LED Sequences and Meaning – IT3870/IT3875 The base contains a green LED that indicates the status of the unit and verifies its communication with the host system. The IT3870/IT3875 contains an LED on the top of the unit to indicate its power up, communication, and charge pack status. Simply stated, red LED = error; green LED = success of any sort; yellow LED = device is working or busy. The unit’s audible indicators have meaning as well -- 3 beeps = error; 2 beeps = menu change; 1 beep = all other successes; clicking/ticking = progress; steady humming = PDF417 decoding The table below lists the indication and cause of the LED illumination and beeps for the IT3870/IT3875. LED Indication

Beeper Indication

Cause

Normal Operation Steady Yellow (IT3870) Yellow - blinking

None None

Steady yellow

Clicking

Steady yellow

Ticking/humming

Steady green

1 beep

Red, blinking

3 beeps

Working/busy Battery low Indicates an association attempt Indicates PDF417 or MicroPDF417 decoding in process Successful communication or association Failed communication or association

Menu Operation Steady green Steady green Red, blinking

1 - 12

Two beeps (high pitch, medium pitch Two beeps (high pitch, medium pitch) 3 beeps (all 3 high pitches)

Successful menu change Successful intermediate menu operation Unsuccessful menu change

Page 33

Beeper and LED Sequences and Meaning - ST5770 The ST5770 contains a beeper and two LEDs on the top of the unit (green and yellow) to indicate its power up, communication, and charge pack status. The tables below list the indication and meaning of the beeps and LED illumination scanner.

ST5770 Scanner LED Indication Sequence

Meaning

Green LED on

Trigger pulled, out of range

Green LED on, 2 seconds

Successful decode and communication

Green LED blinks, 2 seconds

Successful decode with unsuccessful communication, or unsuccessful clear to scanner

Green LED on, 2 seconds

Enter/exit programming mode, successful parameter change in programming mode

Green LED blinks, 2 seconds

Unsuccessful parameter change in programming mode

Yellow LED on

Scanning, trigger pulled (in or out of range)

Yellow LED blinks

Low battery (trigger pulled)

ST5770 Scanner Beep Indication Sequence

Meaning

No beep

No scanning, scanning, or low battery (trigger pulled)

1 beep

Successful decode and communication

Clicking, then1 beep

Successful reassociation

Clicking only

Unsuccessful reassociation

2 beeps, clicks, then1 beep

Successful association to base

3 beeps - same pitch

Unsuccessful association to base (10th scanner), out of range, or no network.

3 beeps - 2 high and 1 low pitch

Enter/exit programming mode or successful association to base. Successful or unsuccessful parameter change in programming mode.

4 beeps - low, high, low, high pitch

Communication error: Successful decode with possible unsuccessful communication to base. Check host to determine if data arrived properly.

1 - 13

Page 34

LED Sequences and Meaning - ST2070 The base contains a green LED that indicates the status of the unit and verifies its communication with the host system.

ST2070 Base LED Indication Sequence

Meaning

LED on continuously

Power on, system idle

LED blinks, long duration

Power on, diagnostic error

LED blinks, short duration

Receiving data from scanner, host, or aux port

LED blinks, four long pulses

Communication error detected

Basic Operation of the Cordless System The following system block diagrams illustrate the basic operating components of the cordless system.

Cordless Base The cordless base provides the link between the cordless scanner and the host system. The base contains a control/interface assembly and an RF communication module. The RF communication module performs the data exchange between the cordless scanner and the control/interface assembly. The control assembly coordinates the central interface activities including: transmitting/receiving commands and data to/from the host system, performing software activities (parameter menuing, visual indicator support, power-on diagnostics), and data translation required for the host system.

Cordless Base RF Module International

Control/Interface Assembly (Base Circuit Board) Control

Antenna

User I/O Host I/O LED RF Power

1 - 14

Menu I/O Multipoint I/O Ports Host Aux

Base Housing

Page 35

RF (Radio Frequency) Module Operation The cordless system uses a state-of-the-art two-way 2.4 GHz frequency-hopping spread spectrum radio to transmit and receive data between the scanner and the base. Designed for point-to-point and multipoint-to-single point applications, the radio transmits data at a rate of 1 megabit per second (Mbps). The radio operates using a license free ISM band, which sends relatively small data packets at a fast data rate over a radio signal with randomly changing frequencies, makes the cordless system highly responsive to a wide variety of data collection applications and resistant to noisy RF environments. The RF radio used in the cordless system has been tested and approved as complying with the two leading standards-setting organizations that serve as regulatory models for compliance in most countries. In North America, the radio is approved under the standards in FCC B Part 15.249 regulations and, in Europe, under the standards in ETS 300 328 regulations.

Cordless Scanner The cordless scanner enables fast and accurate bar code scanning using a noncontact linear imager or laser input engine. The scanner maintains radio communication with the base unit up to 100 feet (30m) depending on the environment. The scanner is comprised of a linear imager or laser scan engine, a decode/ control assembly, and an RF communication module. The scan engine performs the bar code image illumination and sensing. The decode/control assembly coordinates the central communication activities including: capturing and decoding the bar code image data, performing software activities (parameter menuing, visual indicator support, low battery indication), and data translation required for the host system. The RF communication module performs the data exchange between the scanner and the base.

1 - 15

Page 36

Cordless Scanner Scanner Assembly Engine Assembly

Decode/Control Assembly (Handle Board)

Scan Engine (Linear Imager or Laser

Control Trig/Decode

Engine Port

HHLC I/O

Beeper Antenna

Trigger Handle Housing

Menu I/O Power Mgmt

Beeper Port RF Module

RF Port Download Port

Engine Hsg Window/Lt Pipe

Charge Port Charge Pack

System Conditions The components of the cordless system interact in specific ways as you associate one or more scanners to a base, as you move a scanner out of range, bring a scanner back in range, replace a scanner charge pack, or swap scanners between two cordless systems. The following information explains the cordless system operating conditions.

Association Process After you scan the association label, the base synchronizes radio parameters and the work group parameter table in the scanner. The work group table is uploaded during the clicking sequence. Two beeps, clicking, then a single beep indicates the process is complete. The base blinks while it is sending the table to the scanner. Until the table is uploaded, scanning and data transmission is interrupted. If the base is off or not working properly, the scanner emits an error (triple) beep after trying for 30 seconds to associate to the base. The work group table is also uploaded any time the base believes a previously associated scanner wishes to join the network. A scanner always tries to join the last base it was associated to, even if the scanner has been without power for several days. The base allows a scanner to associate as long as there are fewer than nine scanners associated to the base.

1 - 16