Page 21
1
Introduction and Installation
Introduction The cordless scanning system consists of the SCANTEAM 2070 Base unit and at least one IMAGETEAM 3870 Cordless Linear Imager, IMAGETEAM 3875 Cordless Linear Imager, or SCANTEAM 5770 Cordless Laser Scanner. Up to nine IT3870/IT3875 or ST5770 scanners may be associated with one base. Each cordless scanner has a removable, rechargeable charge pack and provides real time decoding within 100 feet (30 m) radius of the base unit depending on the environment. The IT3875 is intended to serve cordless applications that require enhanced user/host interaction. The addition of the 16-key keypad and 97 x 32 pixel graphic (16 character by 4 lines of text) LCD backlit display enables the user to enter data and view confirmation of receipt of data. The IT3875 linear imagers ship with two installed factory scripts and a product demo. These scripts keep track of scan history or part number and quantity. Two PC tools also are available to help generate custom applications: IQ App Loader™ and IQ App Designer™. IQ App Loader is used to compile and load custom script applications created with a text editor. IQ App Designer, an optional PC software tool, automates the creation of scripts and the task of loading a user script application to the system. Using IQ App Designer you may build custom script applications with minimal programming experience. The cordless system is an economical, durable solution for a wide variety of portable data collection applications. The cordless system features: • a tough, ergonomic thermoplastic housing for comfort and durability. • an advanced two-way spread-spectrum radio • recognition and decoding of the most popular, industry-standard bar code symbologies, including PDF417. • coverage of up to 31,416 square feet (2,919 square meters) around the base. • a wide range of interfaces that are compatible with many POS, keyboard wedge, wand and laser emulation, RS-232 terminals, and legacy decoders. • visible and audible feedback for confirmation of a successful decode. • a rechargeable charge pack designed to operate through a whole work day. This manual contains information to help you set up, operate, and program the cordless system. Product specifications, connector pinouts, scan maps, a troubleshooting guide, and customer information are also provided. The cordless system can be programmed for many communications parameters and input/output protocols compatible to the host, as well as advanced data editing and formatting. Programming is accomplished by using the single programming bar codes in this manual. This section contains the following information: • • • •
Cordless System Main Components Charge Pack and Charging Information Cordless System Set Up and Connection Beeper and LED Sequences and Meaning
1-1
Page 22
• Basic Operation of the Cordless System • Communication Between the Cordless System and the Host • Accessories for the Cordless System
1-2
Page 23
Cordless System: Main Components Indicator LED
Cordless Scanner Left Side View
Scan Window
(with charge pack) Trigger Charge Pack Clip (2 places)
Charge Pack
Antenna
Cordless Base Back View
External Power Connector Keyboard/Terminal and RS-232 Connector (Host Port) Aux RS-232, Service Port, and Wand Emulation Output Connector
1-3
Page 24
About the Charge Pack (CLESS/NIMH/S) Power is supplied to the cordless scanner by a rechargeable charge pack that snaps onto the bottom of the scanner. Each scanner is shipped with a charge pack. (See “Charge Pack Specifications (CLESS/NIMH/S)” on page 9-6 for technical specifications.) Note: Order backup charge pack(s) or replacements from your distributor.
North American Charging Information The charge pack is designed to plug into any twoprong North American AC power outlet for direct charging. You need no additional equipment and you can recharge the pack virtually anywhere.
Worldwide Charging Information Since the charge pack is rated for both 120/240 V, 50/60Hz applications, it may be charged worldwide. Inexpensive snap-on adapters and custom 2-bay and 6bay charge strips are available to accommodate a wide variety of electrical outlets internationally.
Charge Pack Recommendations • Charge packs are shipped uncharged and need to be conditioned for full capacity and longer life. • To maintain the maximum charge capacity, charge packs should be allowed to fully discharge prior to charging. It is recommended that you establish a process where a charge pack is used until it is fully discharged and fully charged before its next use. • Avoid using the charge pack in extreme temperatures. • Do not disassemble the charge pack. There are no user-serviceable parts in the charge pack. • Avoid extended overcharging; do not leave the charge pack charging for more than two weeks. Periodically, about every 6 months, repeat the charge pack conditioning.
1-4
Page 25
Proper Disposal of the Charge Pack When the charge pack has reached the end of its useful life, the charge packs should be disposed of by a qualified recycler or hazardous materials handler. Do not incinerate the charge pack or dispose of the charge pack with general waste materials. Contact the Product Service Department (see page 11-1) for recycling or disposal information.
Charging Your Charge Pack (CLESS/NIMH/S) Charge the charge pack by following the steps below: 1. Detach the charge pack from the bottom of the scanner. (See figure below) 2. Fully charge the charge pack. Plug the charge pack directly into any common 120 V AC outlet in North America. If outside North America, use the custom charge strip or adaptor. 3. The LED on the bottom of the charge pack blinks red temporarily as part of the charge initialization sequence. After initialization, the LED remains solid red while the charge pack is charging. The LED shows green when the charge pack is fully charged and ready to use. Recharge Time: 6 hours at any voltage at 20°C (68°F).
Press Release Buttons (2 Places)
4. After the charge pack is fully charged, attach it to the cordless scanner by pressing the pack firmly (align the prongs on the pack with the mating receptacles) in the base of the scanner until the release buttons click, holding the pack firmly in place. (When you attach a charged charge pack to the cordless scanner, you will hear a single beep.) 5. If you have not set up your Cordless System, turn to “Setting Up and Connecting the Cordless System” on page 1-8 for instructions. 6. If the scanner wasn’t previously associated to the base, scan the association bar code on the top of the base. If the scanner was previously associated to a base, it will automatically re-associate. (The association process takes about ten seconds.) When the charge pack needs recharging, the yellow LED on top of the scanner pulses in short, continuous blinks when the trigger is pulled. If the LED stops flashing when the temperature lowers or you do not use the charge pack for some time, you still need to charge the charge pack.
1-5
Page 26
Conditioning the Charge Pack • Charge packs are shipped uncharged and need to be conditioned for full capacity and longer life. • Charge the charge pack for 12 hours for the first two times to fully condition the pack. (Fully discharge in between each initial charge.) • Fully discharge the charge pack on a periodic basis by leaving the charge pack attached to the scanner until the scanner no longer operates, about 24 hours. (Make sure all idle modes are disabled for this procedure -- see “Charge Pack Conservation Mode” on page 2-15).
Discharging the Charge Pack A full discharge should take less than 10 hours. Full discharge is indicated when the trigger is pulled and held for at least 10 seconds and the reader does not illuminate the aiming line or the status LED. Circuitry in the reader prevents an over-discharge.
IMAGETEAM 3870/SCANTEAM 5770 The charge packs naturally discharge through normal use of the reader. Alternately, they may be discharged without user interaction by following these steps: 1. Disassociate the reader from the base unit by scanning the Remove Scanner/Disassociate bar code (found below). 2. Scan the Battery Discharge Mode bar code (found below) to temporarily disable the scanner’s power-saving features. The scanner does not operate normally when in this mode. Do not scan a bar code or the scanner will exit the Battery Discharge Mode. 3. To resume normal operation, detach and replace the charge pack, then associate with the base unit by scanning the bar code affixed to the base.
Remove Scanner/Disassociate
Battery Discharge Mode
1-6
Page 27
IMAGETEAM 3875 You may automatically discharge the IT3875 charge pack by scanning the following bar code. The scanner remains operational during the discharge; however the status LED flashes like a “heartbeat.”
IT3875 Charge Pack Discharge
1-7
Page 28
Setting Up and Connecting the Cordless System Install the base and cordless scanner by following the steps shown below:
Important: Make sure the cordless scanner’s charge pack has been fully charged. See “Charging Your Charge Pack” on page 1-5 for charging instructions.
Keyboard Wedge Interface 1. Turn off the power to the host system. 2. Connect the interface cable to the base and to the terminal/computer (steps 1-3, shown in the illustration below). Depending on your application, the interface cable you need may be different than the one shown.
Keyboard Wedge Interface Example Terminal (Host system)
3 Cordless Base
Disconnect
2 1
(Cable, keyboard, and terminal may vary.)
Note: For optimal coverage, place the base and its antenna as far away from other sources of RF interference, with a clear transmitting path to the scanner(s). The base can be mounted on a wall or a ceiling. Try to place the base so
1-8