Page 37
Note: A scanner always defaults to work group 0 after scanning a base I.D. bar code.
Scanner is Out of Range The cordless scanner is always in communication with its base, even when it is not transmitting bar code data. Whenever the scanner can’t communicate with the base for a three second interval, it is out of range. If the trigger is pulled while the scanner is out of range, the red LED illuminates on the IT3870/IT3875 and the green and yellow LEDs illuminate on the ST5770. When you scan a bar code, the scanner issues 3 beeps and does not try to send data to the base. Note: While the scanner is out of range, it consumes more power searching for the base continuously. To conserve battery power, store the scanner with the charge pack removed, or program it for Charge Pack Conservation mode (see page 2-15).
Scanner is Moved Back Into Range The scanner silently rejoins (no beep after connecting and synchronizing with the base) if the scanner has not been reset (charge pack disconnected and reconnected), no menu codes have been scanned by other scanners in the work group, and the base has not been reset (see Base Reset Conditions, next page). Any one of these three conditions can cause the scanner to go through a reassociation process (definition on page 1-18) when it is moved back in range. If the scanner reassociates, you will hear a single beep when the reassociation process (uploading of the parameter table) is complete. If you believe you are in range and are still hearing a triple (error) beep, you may have been removed from the base’s network. This could happen if the scanner loses power or goes out of range for three seconds. Try scanning the association label or reset the scanner by removing and reinserting the charge pack.
Replacing Charge Pack While Associated When you insert the charge pack, the scanner beeps, followed by clicking. During this period the work group parameter table is uploaded to the scanner from the base. Scanning and data transmission is interrupted. When the scanner emits a second beep, you may scan again. If you don’t receive a second beep, the table was not transferred successfully either because the scanner was out of range or all of the data was not received. Scan the association label again.
Moving Scanners From One Base to Another You may transfer a scanner from one base to another simply by scanning a new base association label. A scanner can only be associated to one base at a time. Once a scanner has been associated to a base, it tries to stay associated to that base until a new base association label has been scanned. The new base adds a scanner to its association list as long as fewer than nine scanners are in its network. If a base has nine scanners in its network, you need to disassociate one scanner before adding another (see next section).
1 - 17
Page 38
Swapping Scanners Between Two Systems with Nine Scanners on Each You may use the Remove Scanner Selection (page 5-4) to disassociate any scanner. Add a new scanner by scanning the association label with the new scanner. If you cannot scan the disassociation label because the scanner you are trying to disassociate was damaged, remove power from that scanner and it automatically disassociates in approximately three seconds.
Glossary Rejoin Rejoin is when the scanner goes out of range and then comes back in range. The scanner silently rejoins (no beep after connecting and synchronizing with the base) if the scanner has not been reset (charge pack disconnected and reconnected), no menu codes have been scanned by other scanners in the work group, and the base has not been reset.
Base Reset Conditions The base resets when base power is lost or when a diagnostic problem is sensed. In either case, the scanners automatically reassociate if they are within range.
Reassociation The process of uploading the work group parameter table from the base is called “reassociation.” During reassociation, the scanner clicks, then beeps once. Reassociation is done automatically, without having to scan an association label.
Association List The base keeps an association list of up to nine entries. This list maintains the associated scanners’ radio serial numbers and dynamic addresses. New dynamic addresses are assigned to the scanners each time a base reset occurs. This helps the cordless system track the status of the different scanners in its network during the association and reassociation process.
Communication Between the Cordless System and the Host The cordless scanner provides immediate feedback in the form of a “good read” indication (a green LED on the scanner and an audible beep) after a bar code is scanned correctly and the base has acknowledged receiving the data. This is possible since the cordless system provides two-way communication between the scanner and the base.
1 - 18
Page 39
When data is scanned, the data is sent to the host system via the base unit. Confirmation from the host system or the base indicates that the data sent was received by the host. The cordless scanner recognizes two forms of host confirmation: data acknowledgement (ACK) from the base unit or an “ACK” from the host system. If it cannot be determined that the data has been properly sent to the host system, the scanner issues an error indication. You must then check to see if the scanned data was received by the host system.
Acknowledgement from the Base If the cordless system is configured for a keyboard wedge host interface, a signal (ACK) is sent from the base confirming that the data was received and is being sent on to the host system. (Since keyboard wedge interfaces cannot provide bi-directional communications, they do not permit host confirmation.)
1) Good Read
3) Base sends data to host after ACK is sent to scanner
2) ACK from base
1 - 19
Page 40
Acknowledgement from the Host Host system confirmation may be implemented with a bi-directional interface like RS-232. In this configuration, when the base unit receives the scanned data from the scanner and forwards it to the host, the cordless system waits for a signal from the host that it received the data. (For information on enabling this feature and using Host Escape commands, see “Host ACK Selection” on page 3-6).
od Go 1)
ad Re
2) m fro
K AC 4) t e) s ho a bas i v (
3)
Da ta to ho s t
AC K
Auxiliary Port The Auxiliary (Aux) Port of the ST2070 is a bi-directional RS-232 port. When the Aux Port is configured as the interface (either using the Plug and Play RS-232 code or terminal ID = 000), the Aux Port is set up to be an RS-232 output port. For all other interfaces, the Aux Port is available as an RS-232 input port. Peripheral devices can send data into the Aux Port, and the data is automatically sent out the main port to the host system.
Note: The Auxiliary Port cannot be used as an input when the base is configured for the following interfaces: Non-Decoded Laser Emulation (HHLC), wand emulation, and terminal ID = 000 (Aux Port RS-232 output).
Aux Port as an RS-232 Output Port When the auxiliary port is configured as an output port, use the Auxiliary Port Protocol section (page 3-11 - page 3-13) to configure baud rate, parity, data bits, stop bits, and flow control. To change outgoing data prefix/suffixes, set up data formatting, and change symbology selections, use the programming selections in Chapter 5.
1 - 20
Page 41
Aux Port as an RS-232 Input Port When the auxiliary port is configured as an input port, incoming messages can be passed on to the host system “as is” or they can be manipulated by the base prior to sending to the host system. This manipulation may include attaching prefixes/suffixes to the message and/or data formatting the message. In order for the base unit to correctly receive a message into the Aux Port, it is recommended that the incoming message be “framed” by known start and stop characters. These characters are attached to the message by the input peripheral, and the base is then programmed to look for these characters. The base unit is then able to recognize the beginning and end of a message, eliminating the possibility of partial messages being sent to the host system. Use the Data Character Selection bar codes (page 3-17) to program these “framing” characters. The Auxiliary Protocol section (page 3-11 - page 3-13) is used to configure baud rate, parity, data bits, stop bits and flow control to match the peripheral protocol settings.
1 - 21
Page 42
Accessories for the Cordless System Several accessories are available for the cordless system. Contact your distributor for more information or to order accessories.
Charge Packs (CLESS/NIMH/S) The charge pack for the cordless scanner is a rechargeable Nickel Metal Hydride (NiMH) pack. The unique design of the charge pack it to be directly charged in a two-prong wall outlet commonly used in North America. The charge pack may be charged anywhere in the world through a universal charge strip to physically adapt to the various power plug and socket configurations. Each scanner is shipped with one charge pack. Order a back up charge pack or a replacement charge pack separately.
Charge Strips To charge more than one charge pack at one time, charge strips are available. The charge strips are offered in two or six outlet configurations and may be conveniently wall mounted or placed on flat surfaces. The charge strip uses a standard PC (IEC 320) grounded power cord between the charge strip and the electrical AC outlet. Note: International versions of the power cords are provided by HHP’s country partners or may be purchased from your local PC supplier. HHP does not supply these power cords.
Charge Pack Adapters Charge pack adapters allow the charge pack to be plugged directly into many international outlet receptacles. After the charge pack is removed from the reader, just snap on an adapter and plug it into an outlet. Two models are available: CLESS/ADAPTEURO for Europlug CEE 7/16 socket types, and CLESS/ADAPTUK for United Kingdom BS 1363 socket types.
Belt Holster The belt holster holds the cordless scanner when not in use. The belt holster consists of a foam covered wire frame clasped to an adjustable nylon web belt designed to be worn around the waist.
Wall Mount Kit (Standard) The standard wall mount holder stores the cordless scanner on a vertical surface for convenient access. The scanner easily slides between two rubberized fingers that hold the scanner when it is not in use.
Wall Mount Kit (Industrial) Similar to the standard wall mount holder, the rubberized fingers on the industrial wall mount holder are smaller to maintain a firm grasp on the scanner under jolting and jarring conditions, such as those expected in fork lift applications.
1 - 22
Page 43
Head Cover The head cover features a “D” ring to attach to a tool balancer to suspend the scanner rather than putting it down.
Base Wall Mount Bracket For applications where the ST2070 base needs to be firmly mounted to a wall. The bracket slides into the molded feature on the back side of the base.
Visual Menu™ Visual Menu is a software configuration tool that provides the ability to configure the cordless system by connecting the base unit to the COM port of a PC. Visual Menu allows you to download firmware upgrades, change programmed parameters, and create and print programming bar codes. Please refer to Chapter 7 for information about installing Visual Menu from the HHP web site.
IQ App Loader™ (IT3875XXX-X2-1 and ST2070-5 only) IQ App Loader is a PC tool that takes script applications you create in a text editor and compiles and loads them into the ST2070-5 base. Please refer to the VersaCode™ Language Reference User’s Guide for additional information.
IQ App Designer™ (IT3875XXX-X2-1 and ST2070-5 only) IQ App Designer is a user friendly PC software tool that automates the development of custom script applications. Although an experienced script programmer probably will find greater flexibility in writing scripts using a standard text editor, this PC tool offers a graphical design environment for rapid development with minimal programming experience. Please refer to the IQ App Designer User’s Guide for additional information.
1 - 23
Page 44
1 - 24