Page 151
Code 11, continued Code 11 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 1-80. Defaults are Minimum = 4, Maximum = 80. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum
Maximum
6 - 21
Page 152
Code 128 <Default All Code 128 Settings>
Code 128
*On
Off
6 - 22
Page 153
Code 128, continued Code 128 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum length range = 0-80 and Maximum length range = 0-80. Defaults are Minimum = 0, Maximum = 80. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum
Maximum
6 - 23
Page 154
Code 128, continued <GS> Substitution A Code 128 FNC1 symbol character may appear in the first or second symbol position to indicate compliance with certain industry standards. If the FNC1 appears in any other symbol position, the reader substitutes a <GS> character (ASCII 1D hex) in the transmitted data. If <GS> Substitution is turned off, the reader ignores all FNC1 characters except those that occur in the first or second symbol position. Default = On.
*On
Off
ISBT 128 The International Society of Blood Transfusion (ISBT) ratified a new standard in 1994 for communicating critical blood information in a uniform manner. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label.
On
*Off
6 - 24
Page 155
Telepen <Default All Telepen Settings>
Telepen
*On
Off
6 - 25
Page 156
Telepen, continued Telepen Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 1-60. Defaults are Minimum = 1, Maximum = 60. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum
Maximum
Telepen Output Telepen has two modes of output: Alphanumeric or Numeric Only. Alphanumeric output complies with AIM guidelines, while Numeric Only is the older, non-compliant, but more common, version of Telepen symbology.
Alphanumeric
*Numeric Only
6 - 26
Page 157
China Post Code (IT3870/IT3875 only) <Default All China Post Code Settings>
China Post Code
On
*Off
6 - 27
Page 158
China Post Code (IT3870/IT3875 only), continued China Post Code Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 2-80. Defaults are Minimum = 4, Maximum = 80. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum
Maximum
6 - 28
Page 159
RSS-14 (IT3870/IT3875 only) Reduced Space Symbology (RSS) is a family of linear bar codes that meets restricted space requirements, while still providing full product identification.
On
*Off
RSS Limited (IT3870/IT3875 only)
On
*Off
RSS Expanded (IT3870/IT3875 only) <Default All RSS Expanded Settings>
On
*Off
6 - 29
Page 160
RSS Expanded (IT3870/IT3875 only), continued RSS Expanded Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 4-74. Defaults are Minimum = 4, Maximum = 74. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum
Maximum
6 - 30